Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 51(6): 3985-3994, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38683935

ABSTRACT

BACKGROUND: Pencil beam scanning (PBS) proton therapy for moving targets is known to be impacted by interplay effects between the scanning beam and organ motion. While respiratory motion in the thoracic region is the major cause for organ motion, interplay effects depend on the delivery characteristics of proton accelerators. PURPOSE: To evaluate the impact of different types of PBS proton accelerators and spot sizes on interplay effects, mitigations, and plan quality for Stereotactic Body Radiation Therapy (SBRT) treatment of non-small cell lung cancer (NSCLC). METHODS: Twenty NSCLC patients treated with photon SBRT were selected to represent varying tumor volumes and respiratory motion amplitudes (median: 0.6 cm with abdominal compression) for this retrospective study. For each patient, plans were created using: (1) cyclotron-generated proton beams (CPB) with spot sizes of σ = 2.7-7.0 mm; (2) linear accelerator proton beams (LPB) (σ = 2.9-5.5 mm); and (3) linear accelerator proton minibeams (LPMB) (σ = 0.9-3.9 mm). The energy switching time is one second for CPB, and 0.005 s for LPMB and LPB. Plans were robustly optimized on the gross tumor volume (GTV) using each individual phase of four-dimensional computed tomography (4DCT) scans. Initially, single-field optimization (SFO) plans were evaluated; if the plan quality did not meet the dosimetric requirement, multi-field optimization (MFO) was used. MFO plans were created for all patients for comparisons. For each patient, all plans were normalized to have the same dose received by 99% of the GTV. Interplay effects were evaluated by computing the dose on 10 breathing phases, based on the spot distribution. Volumetric repainting (VR) was performed 2-6 times for each plan. We compared volume receiving 100% of the prescribed dose (V100%RX) of the GTV, and normal lung V20Gy. RESULTS: Twelve of 20 plans can be optimized sufficiently with SFO. SFO plans were less sensitive to the interplay effect compared to MFO plans in terms of target coverage for both LPB and LPMB. The following comparisons showed results utilizing the MFO technique. In the interplay evaluation without repainting, the mean V100%RX of the GTV were 99.42 ± 0.6%, 97.52 ± 3.9%, and 94.49 ± 7.3% for CPB, LPB, and LPMB plans, respectively. Following VR (2 × for CPB; 3 × for LPB; 5 × for LPMB), V100%RX of the GTV were improved (on average) by 0.13%, 1.84%, and 4.63%, respectively, achieving the acceptance criteria of V100%RX > 95%. Because of fast energy switch in linear accelerator proton machines, the delivery time for VR plans was the lowest for LPB plans, while delivery time for LPMB was on average 1 min longer than CPB plans. The advantage of small spot machines was better sparing in normal lung V20Gy, even when VR was applied. CONCLUSION: In the absence of repainting, proton machines with large spot sizes generated more robust plans against interplay effects. The number of VR increased with decreasing spot sizes to achieve the acceptance criteria. VR improved the plan robustness against interplay effects for modalities with small spot sizes and fast energy changes, preserving the low dose sparing aspect of the LPMB, even when motion is included.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Cyclotrons , Lung Neoplasms , Particle Accelerators , Proton Therapy , Radiosurgery , Radiotherapy Planning, Computer-Assisted , Lung Neoplasms/radiotherapy , Lung Neoplasms/diagnostic imaging , Humans , Radiosurgery/methods , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Carcinoma, Non-Small-Cell Lung/radiotherapy , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Retrospective Studies , Radiotherapy Dosage , Respiration
2.
Med Phys ; 49(4): 2861-2874, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35213040

ABSTRACT

The increased radioresistence of healthy tissues when irradiated at very high dose rates (known as the Flash effect) is a radiobiological mechanism that is currently investigated to increase the therapeutic ratio of radiotherapy treatments. To maximize the benefits of the clinical application of Flash, a patient-specific balance between different properties of the dose distribution should be found, that is, Flash needs to be one of the variables considered in treatment planning. We investigated the Flash potential of three proton therapy planning and beam delivery techniques, each on a different anatomical region. Based on a set of beam delivery parameters, on hypotheses on the dose and dose rate thresholds needed for the Flash effect to occur, and on two definitions of Flash dose rate, we generated exemplary illustrations of the capabilities of current proton therapy equipment to generate Flash dose distributions. All techniques investigated could both produce dose distributions comparable with a conventional proton plan and reach the Flash regime, to an extent that was strongly dependent on the dose per fraction and the Flash dose threshold. The beam current, Flash dose rate threshold, and dose rate definition typically had a more moderate effect on the amount of Flash dose in normal tissue. A systematic estimation of the impact of Flash on different patient anatomies and treatment protocols is possible only if Flash-specific treatment planning features become readily available. Planning evaluation tools such as a voxel-based dose delivery time structure, and the inclusion in the optimization cost function of parameters directly associated with Flash (e.g., beam current, spot delivery sequence, and scanning speed), are needed to generate treatment plans that are taking full advantage of the potential benefits of the Flash effect.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Proton Therapy/methods , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...