Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 82
Filter
1.
J Exp Orthop ; 11(3): e12048, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38863940

ABSTRACT

Purpose: Healing after bone fracture is assessed by clinical examination and frequent radiographs, which expose patients to radiation and lack standardisation. This study aimed to explore electrical impedance patterns during bone healing using electrical impedance spectroscopy in 18 rabbits subjected to tibial fracture stabilised with an external fixator. Methods: Impedance was measured daily across the fracture site at a frequency range of 5 Hz to 1 MHz. Biweekly radiographs were analysed using modified anterior-posterior (AP) radiographic union score of the tibia (RUST). The animals were divided into three groups with different follow-up times: 1, 3 and 6 weeks for micro-computer tomography and mechanical testing. Results: A decreasing trend in impedance was observed over time for all rabbits at lower frequencies. Impedance closest to 5 Hz showed a statistically significant decrease over time, with greatest decrease occurring during the first 7 postoperative days. At 5 Hz, a statistically significant correlation was found between impedance and the modified AP RUST score and between impedance and bone volume fraction. Conclusions: This study showed that the electrical impedance can be measured in vivo at a distance from the fracture site with a consistent change in impedance over time and revealed significant correlation between increasing radiographic union score and decreasing impedance. Level of Evidence: Not applicable.

3.
Acta Orthop ; 95: 225-232, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38757681

ABSTRACT

BACKGROUND AND PURPOSE: Post-discharge inquiries to the hospital are predominantly conducted through phone calls. The rigid timing of these calls is inconvenient for patients and disrupts the workflows of healthcare professionals. The aim of this study was to investigate the effect of a team-based digital communication intervention (eDialogue) facilitated through a messenger-like commercial solution on patient-initiated phone calls to the hospital after discharge. Secondarily, we investigated other patient-initiated contacts, patients' perception of continuity of care, and their perception of feeling safe and satisfied after hospital discharge. METHODS: On the day of discharge, 70 surgically treated orthopedic patients were randomized to the intervention group with access to eDialogue (n = 35) or the control group with standard communication pathways by phone call (n = 35) for the following 8 weeks. Through eDialogue, the intervention group had access to team-based asynchronous digital communication in text and photos with healthcare professionals across disciplines and sectors. Inclusion criteria were discharge to own home and receipt of rehabilitation services from both hospital and primary care after discharge. RESULTS: We found a significant reduction in the mean number of patient-initiated phone calls to the hospital from 2.3 (95% confidence interval [CI] 1.4-4.1) in the control group to 0.5 (CI 0.3-1.0) in the intervention group (P = 0.004). Across groups, patients reported similar perceptions of continuity of care; however, the participants in the intervention group expressed significantly improved perceptions of, and satisfaction with, access to healthcare after discharge. CONCLUSION: Access to eDialogue reduced patient-initiated phone calls to the hospital, enhanced patient satisfaction with healthcare accessibility, and did not compromise patients' perception of continuity of care after discharge compared with standard communication pathways.


Subject(s)
Continuity of Patient Care , Orthopedic Procedures , Patient Discharge , Patient Satisfaction , Humans , Female , Male , Middle Aged , Orthopedic Procedures/methods , Aged , Telephone , Adult , Patient Care Team , Communication
4.
Cureus ; 16(4): e58169, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38616978

ABSTRACT

Background Rotational deformities in children are currently treated with an osteotomy, acute de-rotation, and surgical fixation. Meanwhile, guided growth is now the gold standard in pediatric coronal deformity correction. This study aimed to evaluate the feasibility of a novel implant intended for rotational guided growth (RotOs Plate) in a large porcine animal model. Methodology A submuscular plate was inserted on the medial and lateral aspect of the distal femoral physis of the left femur in 6 pigs. Each plate was anchored with a screw in the metaphysis and epiphysis respectively. The plates were expected to rotate the femur externally. The right femur acted as a control in a paired design. The animals were housed for 12 weeks after surgery. MRI scanning of both femora was performed before euthanasia after 12 weeks. Rotation was determined as the difference in the femoral version on MRI between the operated and non-operated femur after 12 weeks. Results External rotation in all operated femurs was observed. The mean difference in the femoral version on MRI between operated and non-operated femurs was 12.5° (range 9°-16°). No significant changes in axial growth were detected. Conclusions This study shows encouraging results regarding rotational guided growth, which may replace current invasive surgical treatment options for malrotation in children. However, further studies addressing potential secondary deformities are paramount and should be carried out.

5.
JMIR Hum Factors ; 11: e49696, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38551641

ABSTRACT

BACKGROUND: The transition from hospital to home after orthopedic surgery requires smooth communication and coordination between patients and their team of care to avoid fragmented care pathways. Digital communication is increasingly being used to facilitate easy and accessible asynchronous communication between patients and health care professionals across settings. A team-based approach to digital communication may provide optimized quality of care in the postoperative period following orthopedic surgery and hospital discharge. OBJECTIVE: This study was divided into two phases that aimed to (1) explore the perspectives of patients undergoing orthopedic surgery on current communication pathways at a tertiary hospital in Denmark and (2) test and explore patients' experiences and use of team-based digital communication following hospital discharge (eDialogue). METHODS: A triangulation of qualitative data collection techniques was applied: document analysis, participant observations (n=16 hours), semistructured interviews with patients before (n=31) and after (n=24) their access to eDialogue, and exploration of use data. RESULTS: Findings show that patients experience difficult communication pathways after hospital discharge and a lack of information due to inadequate coordination of care. eDialogue was used by 84% (26/31) of the patients, and they suggested that it provided a sense of security, coherence, and proximity in the aftercare rearranging communication pathways for the better. Specific drivers and barriers to use were identified, and these call for further exploration of eDialogue. CONCLUSIONS: In conclusion, patients evaluated eDialogue positively and suggested that it could support them after returning home following orthopedic surgery.


Subject(s)
Orthopedic Procedures , Patient Discharge , Humans , Qualitative Research , Communication , Tertiary Care Centers
6.
Dan Med J ; 71(3)2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38445315

ABSTRACT

INTRODUCTION: Continuous peripheral nerve blocks (cPNBs) have shown favourable post-operative pain control results but may be associated with a risk for long-term neurological complications. This study sought to examine factors associated with persistent post-operative pain and potential neuropathy after orthopaedic lower-limb surgery with the use of post-operative cPNB. METHODS: Patients who underwent lower limb orthopaedic procedures with cPNBs between November 2021 to May 2022 were included. Patient demographics and perioperative data were noted. At discharge, patients completed the PainDetect (PD) questionnaire and were followed up six months after discharge. RESULTS: Seventy-seven patients with a total of 171 catheters completed the follow up. The median time to follow-up was 214 days after catheter removal, and 18 patients (23%) had a PD score ≥ 13. Univariate analysis showed that multiple variables were associated with a PD score ≥ 13 at the six-month follow-up. Multiple logistic regression showed that a high PD score at discharge, high BMI and longer duration of cPNBs were associated with higher risk of having a PD score ≥ 13 at the six-month follow-up. CONCLUSION: Several factors were associated with a higher risk of having possible neuropathy after six months. BMI, duration of catheter and PD score at discharge were correlated with risk of possible neuropathic pain. FUNDING: None. TRIAL REGISTRATION: The study was a quality control project and therefore did not require registration under Danish law.


Subject(s)
Neuralgia , Orthopedic Procedures , Orthopedics , Humans , Orthopedic Procedures/adverse effects , Neuralgia/etiology , Pain, Postoperative/etiology , Peripheral Nerves
7.
JMIR Hum Factors ; 11: e53391, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38457798

ABSTRACT

BACKGROUND: Orthopedic surgical treatment is a transversal task that requires the active involvement of patients, relatives, and health care professionals (HCPs) across various settings. However, after hospital discharge, communication is challenged and undertaken primarily by phone. New digital communication solutions have the potential to create a space for seamless and patient-centered dialogue across discipline and sector boundaries. When evaluating new communication solutions, knowledge about HCPs' needs and perspectives of use must be explored, as it is they who are responsible for implementing changes in practice. OBJECTIVE: This study aimed to (1) investigate HCPs' perceptions of current communication pathways (phase 1) and (2) explore their experiences of using a simple messenger-like solution (eDialogue) for team-based digital communication across settings (phase 2). METHODS: We used a triangulation of qualitative data collection techniques, including document analysis, observations, focus groups, and individual interviews of HCPs before (n=28) and after (n=12) their use of eDialogue. Data collection and analysis were inspired by the Consolidated Framework for Implementation Research (CFIR) to specifically understand facilitators and barriers to implementation as perceived by HCPs. RESULTS: HCPs perceive current communication pathways as insufficient for both patients and themselves. Phone calls are disruptive, and there is a lack of direct communication modalities when communication crosses sector boundaries. HCPs experienced the use of eDialogue as a quick and easy way for timely interdisciplinary interaction with patients and other HCPs across settings; however, concerns were raised about time consumption. CONCLUSIONS: eDialogue can provide needed support for interdisciplinary and cross-sectoral patient-centered communication. However, future studies of this solution should address its impact and the use of resources.


Subject(s)
Communication , Health Personnel , Humans , Qualitative Research , Focus Groups , Document Analysis
8.
J Pediatr Orthop B ; 2024 Feb 05.
Article in English | MEDLINE | ID: mdl-38324644

ABSTRACT

Epiphysiodesis is considered the preferred treatment for children predicted to have leg length discrepancies (LLDs) 2-5 cm at maturity. The aim of this study was to systematically review the existing literature on the effectiveness of permanent epiphysiodesis for LLD treatment, and secondarily to address the reported complications of permanent epiphysiodesis techniques. This systematic review was performed according to PRISMA guidelines. We searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with permanent epiphysiodesis. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre/post-operatively, successful/unsuccessful), physeal fusion/arrest, and complications that were graded on severity. Forty-nine studies (3051 patients) were included, 1550 underwent Phemister/modified Phemister epiphysiodesis and 1501 percutaneous epiphysiodesis (PE). Total successful permanent epiphysiodesis surgeries (16 studies) were 73.7% (516/700). Only 13 out of 23 studies had a mean final LLD of less than 1.5 cm. In total, 17.5% (513/2936) of complications were reported. 57 angular deformities were reported (1.9%). Phemister technique had higher percentage of complications (39%) than PE (19.1%) in total, but when failure to achieve adequate reduction in LLD was not included, complication rates for both were close to 14%. However, severe complications were 10.2% for Phemister group and 5.1% for PE. The high complication rates and the relative low success rate call for optimization of the timing and the applied techniques when treating LLD with permanent epiphysiodesis. Phemister technique was found to have higher percentage of severe complications than PE. Registration: PROSPERO (CRD42023435177).

9.
EFORT Open Rev ; 9(2): 119-128, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38308954

ABSTRACT

Purpose: The objective of this scoping review was to describe the extent and type of evidence of using guided growth to correct rotational deformities of long bones in children. Methods: This scoping review was conducted in accordance with the JBI methodology for scoping reviews. All published and unpublished studies investigating surgical methods using guided growth to perform gradual rotation of long bones were included. Results: Fourteen studies were included: one review, three clinical studies, and ten preclinical studies. In the three clinical studies, three different surgical methods were used on 21 children. Some degree of rotation was achieved in all but two children. Adverse effects reported included limb length discrepancy (LLD), knee stiffness and rebound of rotation after removal of tethers. Of the ten preclinical studies, two were ex vivo and eight were in vivo. Rotation was achieved in all preclinical studies. Adverse effects reported included implant extrusions, LLD, articular deformities, joint stiffness and rebound of rotation after removal of tethers. Two of the studies reported on histological changes. Conclusions: All studies conclude that guided growth is a potential treatment for rotational deformities of long bones. There is great variation in animal models and surgical methods used and in reported adverse effects. More research is needed to shed light on the best surgical guided growth method, its effectiveness as well as the involved risks and complications. Based on current evidence the procedure is still to be considered experimental. Level of evidence: 4.

10.
J Orthop Case Rep ; 14(1): 68-74, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38292091

ABSTRACT

Introduction: The aim is to report early clinical results of an experimental surgical procedure, injecting bone void filler, for patients with lower extremity rheumatoid arthritis (RA) insufficiency fractures. Case Report: We used a cross-sectional design with retrospective follow-up. Patient-reported outcomes were reported by the body-region specific questionnaires, knee injury and osteoarthritis outcome score (KOOS), or foot and ankle outcome score (FOAS). The Eq5D-5L questionnaire reported overall health-related quality of life (QoL). Furthermore, patient satisfaction (semi-structured interview), pain reactions, and adverse events were reported.Results from the first five patients were included. The median age was 70 years (range 50-80). Fracture localizations were proximal tibia (2), distal tibia (2), and distal femur (1). Four out of five patients reported a high degree of patient satisfaction following treatment. Four out of five patients at follow-up reported no pain from the fracture location. The median improvement from baseline to follow-up on the KOOS/FAOS subscale scores was pain 65 (range 42-69), symptoms 39 (range 25-50), the activity of daily living 41 (range 29-51), sport and recreational activities (sport/rec) 48 (range 40-60), and QoL 60 (range 57-72). The median improvement for the Eq5D index was 0.30 (range 0.26-0.36). Conclusion: Surgical treatment of insufficiency fractures in RA patients with bone void filler seems promising. Four out of five patients reported considerable improvement in function and QoL and substantially lower pain scores following treatment. More research is needed to investigate the efficacy of this novel surgical procedure.

11.
Bone Jt Open ; 5(1): 3-8, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38164740

ABSTRACT

Aims: The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. Methods: We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots. Results: We included 2,735 newborns, of whom 754 received a follow-up hip ultrasound within six weeks of age. After exclusion, 1,500 hips were included for analysis. Sex distribution was 372 male and 380 female, and the mean age at examination was 36.6 days (4 to 87). We found a negative linear correlation of PFD to α angles (p < 0.001), FHC (p < 0.001), and FHC during provocation (p < 0.001) with a 1 mm increase in PFD corresponding to a -2.1° (95% confidence interval (CI) -2.3 to -1.9) change in α angle and a -3.4% (95% CI -3.7 to -3.0) change in FHC and a -6.0% (-6.6 to -5.5) change in FHC during provocation. The PFD was significantly higher with increasing Graf types and in displaceable hips (p < 0.001). Conclusion: PFD is strongly correlated to both α angles and hip displaceability, as measured by FHC and FHC during provocation, in ultrasound of newborn hips. The PFD increases as the hips become more dysplastic and/or displaceable.

12.
Acta Orthop ; 94: 594-599, 2023 12 13.
Article in English | MEDLINE | ID: mdl-38093629

ABSTRACT

BACKGROUND AND PURPOSE: There is inconsistency in the literature regarding the relationship between increased birthweight and risk of developmental dysplasia of the hip (DDH). We aimed to investigate the correlation between birthweight and pubo-femoral distance (PFD), as well as Graf's α angle in newborns undergoing hip ultrasound examination at 6 weeks of age. PATIENTS AND METHODS: Basic newborn characteristics and ultrasound measurements were retrospectively collected during a 1-year study period. We excluded multiple births, newborns born at less than 37 gestational weeks, and incomplete information. Simple and multiple linear regression analyses were performed to evaluate the correlation of birthweight and PFD, and, second, birthweight and α angles including a stratified regression analysis investigating the potential effect modification of sex. RESULTS: 707 newborns (1,414 hips) were included. Mean birthweight was significantly higher for male newborns (P < 0.001). Increased birthweight was positively correlated to PFD values (crude coefficient 0.21, 95% confidence interval [CI] 0.10-0.32) and the correlation was still present after adjusting for sex, family history, and breech presentation (adjusted coefficient 0.18, CI 0.07-0.29). The stratified α angle model for the males was significant for both the crude coefficient (-0.73, CI -1.28 to -0.19) and the adjusted (-0.59, CI -1.15 to -0.03), and also for the females (crude coefficient -1.14, CI -1.98 to -0.31 and adjusted coefficient -1.15, CI -1.99 to -0.31). CONCLUSION: We found that increased birthweight positively correlated to PFD, and negatively correlated to α angle, but this was not of clinical significance.


Subject(s)
Hip Dislocation, Congenital , Pregnancy , Female , Humans , Infant, Newborn , Male , Retrospective Studies , Hip Dislocation, Congenital/diagnostic imaging , Hip Dislocation, Congenital/epidemiology , Birth Weight , Femur/diagnostic imaging , Physical Examination , Ultrasonography
13.
JMIR Mhealth Uhealth ; 11: e44442, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37283228

ABSTRACT

BACKGROUND: Smartphones are often equipped with inertial sensors that measure individuals' physical activity (PA). However, their role in remote monitoring of the patients' PAs in telemedicine needs to be adequately explored. OBJECTIVE: This study aimed to explore the correlation between a participant's actual daily step counts and the daily step counts reported by their smartphone. In addition, we inquired about the usability of smartphones for collecting PA data. METHODS: This prospective observational study was conducted among patients undergoing lower limb orthopedic surgery and a group of nonpatients as control. The data from the patients were collected from 2 weeks before surgery until 4 weeks after the surgery, whereas the data collection period for the nonpatients was 2 weeks. The participant's daily step count was recorded by PA trackers worn 24/7. In addition, a smartphone app collected the number of daily steps registered by the participants' smartphones. We compared the cross-correlation between the daily steps time series obtained from the smartphones and PA trackers in different groups of participants. We also used mixed modeling to estimate the total number of steps, using smartphone step counts and the characteristics of the patients as independent variables. The System Usability Scale was used to evaluate the participants' experience with the smartphone app and the PA tracker. RESULTS: Overall, 1067 days of data were collected from 21 patients (n=11, 52% female patients) and 10 nonpatients (n=6, 60% female patients). The median cross-correlation coefficient on the same day was 0.70 (IQR 0.53-0.83). The correlation in the nonpatient group was slightly higher than that in the patient group (median 0.74, IQR 0.60-0.90 and median 0.69, IQR 0.52-0.81, respectively). The likelihood ratio tests on the models fitted by mixed effects methods demonstrated that the smartphone step count was positively correlated with the PA tracker's total number of steps (χ21=34.7, P<.001). In addition, the median usability score for the smartphone app was 78 (IQR 73-88) compared with median 73 (IQR 68-80) for the PA tracker. CONCLUSIONS: Considering the ubiquity, convenience, and practicality of smartphones, the high correlation between the smartphones and the total daily step count time series highlights the potential usefulness of smartphones in detecting changes in the number of steps in remote monitoring of a patient's PA.


Subject(s)
Mobile Applications , Smartphone , Humans , Female , Male , Feasibility Studies , Exercise , Data Collection
14.
J Orthop Case Rep ; 13(2): 5-9, 2023 Feb.
Article in English | MEDLINE | ID: mdl-37144065

ABSTRACT

Introduction: X-linked hypophosphatemic rachitis (XLHR) is the most common cause of hereditary rickets that can lead to long bone deformities requiring multiple surgical correction procedures. In addition, high rates of fractures are reported in adult XLHR patients. This study aimed to report a case of femoral neck stress fracture in XLHR patient treated with mechanical axis correction. No previous studies demonstrating a combined valgus correction and cephalomedullary nail fixation were identified in the literature. Case Report: A 47-year-old male patient with XLHR attended the outpatient clinic with severe left hip pain. X-rays revealed a left proximal femoral varus deformity and a femoral neck stress fracture. After 1 month without improvement of pain, and no radiographic sign of healing, correction of the proximal femoral varus deformity and fixation of the cervical neck fracture was achieved by a cephalomedullary nail. At 8 months follow-up, hip pain relief was achieved with radiographic healing of the femoral neck stress fracture and the proximal femoral osteotomy. Conclusion: A review of the literature was performed to identify any case report of femoral neck fractures fixation due to coxa vara in an adult. Both coxa vara and XLHR can cause femoral neck stress fracture. This study presented the surgical technique for treating a rare case of femoral neck stress fracture in a XLHR patient with coxa vara. Pain relief and bone healing were achieved by combined deformity correction and fracture fixation with a femoral cephalomedullary nail. The technique for deformity correction and cephalomedullary nail insertion in the patient with coxa vara is shown.

15.
Sensors (Basel) ; 23(5)2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36904954

ABSTRACT

Determining the presence and severity of knee osteoarthritis (OA) is a valuable application of inertial measurement units (IMUs) in the remote monitoring of patients. This study aimed to employ the Fourier representation of IMU signals to differentiate between individuals with and without knee OA. We included 27 patients with unilateral knee osteoarthritis (15 females) and 18 healthy controls (11 females). Gait acceleration signals were recorded during overground walking. We obtained the frequency features of the signals using the Fourier transform. The logistic LASSO regression was employed on the frequency domain features as well as the participant's age, sex, and BMI to distinguish between the acceleration data from individuals with and without knee OA. The model's accuracy was estimated by 10-fold cross-validation. The frequency contents of the signals were different between the two groups. The average accuracy of the classification model using the frequency features was 0.91 ± 0.01. The distribution of the selected features in the final model differed between patients with different severity of knee OA. In this study, we demonstrated that using logistic LASSO regression on the Fourier representation of acceleration signals can accurately determine the presence of knee OA.


Subject(s)
Osteoarthritis, Knee , Female , Humans , Knee Joint , Gait , Walking , Acceleration , Biomechanical Phenomena
16.
Acta Orthop ; 94: 51-59, 2023 02 17.
Article in English | MEDLINE | ID: mdl-36807707

ABSTRACT

BACKGROUND AND PURPOSE: Intramedullary bone-lengthening nails have become increasingly popular. The 2 most used and successful nails are the FITBONE and the PRECICE nails. Uniform reporting is lacking on complications of intramedullary bone-lengthening nails. The purpose was therefore to assess and categorize the complications of lower limb bone-lengthening nails and investigate risk factors. PATIENTS AND METHODS: We performed a retrospective review of patients operated on with intramedullary lengthening nails at 2 hospitals. We included only lower limb lengthening with FITBONE and PRECICE nails. Recorded patient data was patient demographics, nail information, and any complication. Complications were graded according to severity and origin classification. Complication risk factors were assessed with modified Poisson regression. RESULTS: 314 segments in 257 patients were included. The FITBONE nail was predominantly used (75%), and most of the lengthenings were performed in the femur (80%). 53% of the patients had complications. 269 complications were identified in 175 segments (144 patients). Device-related complications were most frequent (0.3 complications/segment), followed by joint complications (0.2 complications/segment). An increased relative risk was found for complications in the tibia compared with the femur and for age groups above 30 years compared with the 10-19 years group. CONCLUSION: Complications with intramedullary bone lengthening nails were more frequent than has previously been reported, with 53% of patients sustaining a complication. Future studies need to document the complications meticulously so that the true risk can be established.


Subject(s)
Bone Lengthening , Fracture Fixation, Intramedullary , Humans , Adult , Fracture Fixation, Intramedullary/adverse effects , Leg Length Inequality/surgery , Cohort Studies , Nails , Bone Nails , Femur/surgery , Risk Factors , Retrospective Studies , Treatment Outcome
17.
J Geriatr Cardiol ; 19(9): 712-718, 2022 Sep 28.
Article in English | MEDLINE | ID: mdl-36284681

ABSTRACT

BACKGROUND: It has previously been described that fall-associated injuries including fractures are commonly observed among patients with bradyarrhythmia. However, knowledge on the risk of pacemaker implantation after admission due to femur fracture from large population-based epidemiologic data is lacking. Therefore, we investigated the risk of pacemaker implantation following femur fracture in patients with and without a history of previous syncope. METHODS: All patients with femur fracture between 2005-2017 were identified using the Danish Nationwide Patient Registry. Among these, patients already having a pacemaker were excluded. Primary outcome was one-year risk of pacemaker implantation and secondary outcome was one-year all-cause mortality. Multivariable logistic regression was used to obtain absolute and relative risks of the study endpoint in relation to patients with versus without history of syncope and standardized to the age, sex, selected comorbidity and pharmacotherapy distribution of all patients. RESULTS: Of 93,093 patients with femur fracture, 5508 (5.9%) had a history of syncope within five years. Patients with prior syncope were slightly older (84 vs. 83 years), more often male (33.6% vs. 29.4%), and had more often comorbidities relative to those without history of syncope. All-cause mortality was significantly higher among those with previous history of syncope compared to those without previous syncope (29.9% vs. 28.6%, P = 0.021). The relative mortality risk was 1.05 (95% CI: 1.01-1.09, P = 0.021). A total of 695 (0.8%) patients underwent pacemaker implantation within 5 years following femur fracture, and a significantly higher proportion of patients with syncope had a pacemaker implanted within one year (1.6% vs. 0.7%, P < 0.001; relative risk, 2.01 [95% CI: 1.55-2.46]). CONCLUSIONS: In patients with femur fracture, a history of syncope was significantly associated with a higher one-year risk of pacemaker implantation.

18.
BMJ Open ; 12(9): e062087, 2022 09 22.
Article in English | MEDLINE | ID: mdl-36137634

ABSTRACT

INTRODUCTION: After discharge, patients face multiple risks where timely communication with healthcare professionals is required. eHealth has proposed new possibilities for asynchronous text-based two-way communication between patients and healthcare professionals during this time, and studies show positive effects on clinical outcomes, care coordination and patient satisfaction. However, there are challenges to the adoption of text-based two-way communication, potentially undermining the positive effects in clinical practice. Knowledge of these factors may inform future research and implementations. No reviews have provided an overview of the use of text-based two-way communication after discharge and the identified facilitators and barriers. Therefore, the objective of this scoping review is to systematically identify and map available research that assess the use of text-based two-way communication between patients and healthcare professionals after hospital discharge, including facilitators and barriers to implementation. METHODS AND ANALYSIS: We will include all studies describing the use of text-based two-way communication between patients and healthcare professionals after discharge from hospital. A preliminary search of PubMed (PubMed.gov), EMBASE (Elsevier), CINAHL (EBSCO), PsycINFO (Ovid), Cochrane Library (Wiley), Web of Science (Clarivate) and Scopus (Elsevier) was undertaken on 9 November 2021. The search will be updated for the full scoping review, and reference lists of relevant papers reviewed. Two reviewers will independently screen the literature for inclusion. Data will be extracted and charted in accordance with a data extraction form developed from the research questions and inspired by Consolidated Framework Implementation Research. Findings will be presented in tabular format and a descriptive summary, and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews checklist. ETHICS AND DISSEMINATION: This scoping review will not require ethics approval. The dissemination strategy involves peer review publication and presentation at conferences.


Subject(s)
Health Personnel , Patient Discharge , Communication , Delivery of Health Care , Hospitals , Humans , Research Design , Review Literature as Topic , Systematic Reviews as Topic
19.
Digit Health ; 8: 20552076221109502, 2022.
Article in English | MEDLINE | ID: mdl-35783467

ABSTRACT

Background: Patients with severe bone fractures and complex bone deformities are treated by orthopedic surgeons with external fixation for several months. During this long treatment period, there is a high risk of inflammation and infection at the superficial skin area (pin site). This can develop into a devastating, sometimes fatal, and always costly condition of deep bone infection. Objective: For pin site infection surveillance, thermography technology could be the solution to build an objective and continuous home-based remote monitoring tool to avoid frequent nursing care and hospital visits. However, future studies of infection monitoring require a preliminary step to automate the process of locating and detecting the pin sites in thermal images reliably for temperature measurement, and this step is the aim of this study. Methods: This study presents an automatic approach for identifying and annotating pin sites on visible images using bounding boxes and transferring them to the corresponding thermal images for temperature measurement. The pin site is detected by applying deep learning-based object detection architecture YOLOv5 with a novel loss evaluation and regression method, control distance intersection over union. Furthermore, we address detecting pin sites in a practical environment (home setting) accurately through transfer learning. Results and conclusion: The proposed model offers the pin site detection in 1.8 ms with a high precision of 0.98 and enables temperature information extraction. Our work for automatic pin site annotation on thermography paves the way for future research on infection assessment on thermography.

20.
Sensors (Basel) ; 22(14)2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35890969

ABSTRACT

Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.


Subject(s)
Osteoarthritis, Knee , Acceleration , Accelerometry , Aged , Biomechanical Phenomena , Gait , Humans , Reproducibility of Results , Walking
SELECTION OF CITATIONS
SEARCH DETAIL
...