Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
JOR Spine ; 7(2): e1335, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38741919

ABSTRACT

Background: In vivo quantification of the structure-function relationship of the intervertebral disc (IVD) via quantitative MRI has the potential to aid objective stratification of disease and evaluation of restorative therapies. Magnetic resonance elastography (MRE) is an imaging technique that assesses tissue shear properties and combined with quantitative MRI metrics reflective of composition can inform structure-function of the IVD. The objectives of this study were to (1) compare MRE- and rheometry-derived shear modulus in agarose gels and nucleus pulposus (NP) tissue and (2) correlate MRE and rheological measures of NP tissue with composition and quantitative MRI. Method: MRE and MRI assessment (i.e., T1ρ and T2 mapping) of agarose samples (2%, 3%, and 4% (w/v); n = 3-4/%) and of bovine caudal IVDs after equilibrium dialysis in 5% or 25% PEG (n = 13/PEG%) was conducted. Subsequently, agarose and NP tissue underwent torsional mechanical testing consisting of a frequency sweep from 1 to 100 Hz at a rotational strain of 0.05%. NP tissue was additionally evaluated under creep and stress relaxation conditions. Linear mixed-effects models and univariate regression analyses evaluated the effects of testing method, %agarose or %PEG, and frequency, as well as correlations between parameters. Results: MRE- and rheometry-derived shear moduli were greater at 100 Hz than at 80 Hz in all agarose and NP tissue samples. Additionally, all samples with lower water content had higher complex shear moduli. There was a significant correlation between MRE- and rheometry-derived modulus values for homogenous agarose samples. T1ρ and T2 relaxation times for agarose and tissue were negatively correlated with complex shear modulus derived from both techniques. For NP tissue, shear modulus was positively correlated with GAG/wet-weight and negatively correlated with %water content. Conclusion: This work demonstrates that MRE can assess hydration-induced changes in IVD shear properties and further highlights the structure-function relationship between composition and shear mechanical behaviors of NP tissue.

2.
Res Sq ; 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38562870

ABSTRACT

The lung is a dynamic mechanical organ and several pulmonary disorders are characterized by heterogeneous changes in the lung's local mechanical properties (i.e. stiffness). These alterations lead to abnormal lung tissue deformation (i.e. strain) which have been shown to promote disease progression. Although heterogenous mechanical properties may be important biomarkers of disease, there is currently no non-invasive way to measure these properties for clinical diagnostic purposes. In this study, we use a magnetic resonance elastography technique to measure heterogenous distributions of the lung's shear stiffness in healthy adults and in people with Cystic Fibrosis. Additionally, computational finite element models which directly incorporate the measured heterogenous mechanical properties were developed to assess the effects on lung tissue deformation. Results indicate that consolidated lung regions in people with Cystic Fibrosis exhibited increased shear stiffness and reduced spatial heterogeneity compared to surrounding non-consolidated regions. Accounting for heterogenous lung stiffness in healthy adults did not change the globally averaged strain magnitude obtained in computational models. However, computational models that used heterogenous stiffness measurements predicted significantly more variability in local strain and higher spatial strain gradients. Finally, computational models predicted lower strain variability and spatial strain gradients in consolidated lung regions compared to non-consolidated regions. These results indicate that spatial variability in shear stiffness alters local strain and strain gradient magnitudes in people with Cystic Fibrosis. This imaged-based modeling technique therefore represents a clinically viable way to non-invasively assess lung mechanics during both health and disease.

3.
J Biomech ; 164: 111965, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38354514

ABSTRACT

Nucleus pulposus (NP) tissue in the intervertebral disc (IVD) is a viscoelastic material exhibiting both solid- and fluid-like mechanical behaviors. Advances in viscoelastic models incorporating fractional calculus, such as the Fractional Zener (FZ) model, have potential to describe viscoelastic behaviors. The objectives of this study were to determine whether the FZ model can accurately describe the shear viscoelastic properties of NP tissue and determine if the fractional order (α) is related to tissue hydration. 30 caudal IVDs underwent equilibrium dialysis in 5% or 25% polyethylene glycol solutions to alter tissue hydration. Excised NP tissue underwent stress relaxation testing in shear and unconfined compression. Stress relaxation data was fitted to the FZ model to obtain viscoelastic properties. In both loading modes, the initial modulus was greater for the less hydrated 25% equilibrated samples compared to 5% with no change in the equilibrium modulus. Samples with lower water content (25% samples) had shorter relaxation times in shear and longer time constants in compression, highlighting the different interactions between the fluid and solid matrix in loading modes. Samples with lower water content had α values closer to 0, indicating that less hydrated samples behaved more solid-like on the viscoelastic spectrum. Tissue hydration correlated with α values for 25% samples in shear. This study demonstrates that the FZ model may be used to describe IVD tissue behavior under both loading modes; however, the greatest utility of the FZ model is in describing flow-independent shear behaviors, and α may inform tissue hydration in shear.


Subject(s)
Intervertebral Disc , Nucleus Pulposus , Elasticity , Stress, Mechanical , Water
4.
Invest Radiol ; 58(4): 299-306, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36730906

ABSTRACT

BACKGROUND: Idiopathic pulmonary fibrosis is responsible for 40,000 deaths annually in the United States. A hallmark of idiopathic pulmonary fibrosis is elevated collagen deposition, which alters lung stiffness. Clinically relevant ways to measure changes in lung stiffness during pulmonary fibrosis are not available, and new noninvasive imaging methods are needed to measure changes in lung mechanical properties. OBJECTIVES: Magnetic resonance elastography (MRE) is an in vivo magnetic resonance imaging technique proven to detect changes in shear stiffness in different organs. This study used MRE, histology, and bronchoalveolar lavage (BAL) to study changes in the mechanical and structural properties of the lungs after bleomycin-induced pulmonary fibrosis in pigs. MATERIALS AND METHODS: Pulmonary fibrosis was induced in 9 Yorkshire pigs by intratracheal instillation of 2 doses of bleomycin into the right lung only. Magnetic resonance elastography scans were performed at baseline and week 4 and week 8 postsurgery in a 1.5 T magnetic resonance imaging scanner using a spin-echo echo planar imaging sequence to measure changes in lung shear stiffness. At the time of each scan, a BAL was performed. After the final scan, whole lung tissue was removed and analyzed for histological changes. RESULTS: Mean MRE-derived stiffness measurements at baseline, week 4, and week 8 for the control (left) lungs were 1.02 ± 0.27 kPa, 0.86 ± 0.29 kPa, and 0.68 ± 0.20 kPa, respectively. The ratio of the shear stiffness in the injured (right) lung to the uninjured control (left) lung at baseline, week 4, and week 8 was 0.98 ± 0.23, 1.52 ± 0.41, and 1.64 ± 0.40, respectively. High-dose animals showed increased protein in BAL fluid, elevated inflammation observed by the presence of patchy filtrates, and enhanced collagen and α-smooth muscle actin staining on histological sections. Low-dose animals and the control (left) lungs of high-dose animals did not show significant histopathological changes. CONCLUSION: This study demonstrated that MRE can be used to detect changes in lung stiffness in pigs after bleomycin challenge.


Subject(s)
Elasticity Imaging Techniques , Idiopathic Pulmonary Fibrosis , Animals , Swine , Elasticity Imaging Techniques/methods , Bleomycin , Lung/diagnostic imaging , Lung/pathology , Magnetic Resonance Imaging/methods , Models, Animal , Idiopathic Pulmonary Fibrosis/pathology
5.
Magn Reson Med ; 88(4): 1840-1850, 2022 10.
Article in English | MEDLINE | ID: mdl-35691940

ABSTRACT

PURPOSE: Magnetic resonance elastography (MRE) maps the viscoelastic properties of soft tissues for diagnostic purposes. However, different MRE inversion methods yield different results, which hinder comparison of values, standardization, and establishment of quantitative MRE markers. Here, we introduce an expandable, open-access, webserver-based platform that offers multiple inversion techniques for multifrequency, 3D MRE data. METHODS: The platform comprises a data repository and standard MRE inversion methods including local frequency estimation (LFE), direct-inversion based multifrequency dual elasto-visco (MDEV) inversion, and wavenumber-based (k-) MDEV. The use of the platform is demonstrated in phantom data and in vivo multifrequency MRE data of the kidneys and brains of healthy volunteers. RESULTS: Detailed maps of stiffness were generated by all inversion methods showing similar detail of anatomy. Specifically, the inner renal cortex had higher shear wave speed (SWS) than renal medulla and outer cortex without lateral differences. k-MDEV yielded higher SWS values than MDEV or LFE (full kidney/brain k-MDEV: 2.71 ± 0.19/1.45 ± 0.14 m/s, MDEV: 2.14 ± 0.16/0.99 ± 0.11 m/s, LFE: 2.12 ± 0.15/0.89 ± 0.06 m/s). CONCLUSION: The freely accessible platform supports the comparison of MRE results obtained with different inversion methods, filter thresholds, or excitation frequencies, promoting reproducibility in MRE across community-developed methods.


Subject(s)
Elasticity Imaging Techniques , Brain/anatomy & histology , Brain/diagnostic imaging , Elasticity Imaging Techniques/methods , Humans , Kidney/diagnostic imaging , Magnetic Resonance Imaging/methods , Reproducibility of Results
6.
Radiology ; 304(3): 721-729, 2022 09.
Article in English | MEDLINE | ID: mdl-35638926

ABSTRACT

Background Abdominal aortic aneurysm (AAA) diameter remains the standard clinical parameter to predict growth and rupture. Studies suggest that using solely AAA diameter for risk stratification is insufficient. Purpose To evaluate the use of aortic MR elastography (MRE)-derived AAA stiffness and stiffness ratio at baseline to identify the potential for future aneurysm rupture or need for surgical repair. Materials and Methods Between August 2013 and March 2019, 72 participants with AAA and 56 healthy participants were enrolled in this prospective study. MRE examinations were performed to estimate AAA stiffness and the stiffness ratio between AAA and its adjacent remote normal aorta. Two Cox proportional hazards models were used to assess AAA stiffness and stiffness ratio for predicting aneurysmal events (subsequent repair, rupture, or diameter >5.0 cm). Log-rank tests were performed to determine a critical stiffness ratio suggesting high-risk AAAs. Baseline AAA stiffness and stiffness ratio were studied using Wilcoxon rank-sum tests between participants with and without aneurysmal events. Spearman correlation was used to investigate the relationship between stiffness and other potential imaging markers. Results Seventy-two participants with AAA (mean age, 71 years ± 9 [SD]; 56 men and 16 women) and 56 healthy participants (mean age, 42 years ± 16; 27 men and 29 women) were evaluated. In healthy participants, aortic stiffness positively correlated with age (ρ = 0.44; P < .001). AAA stiffness (event group [n = 21], 50.3 kPa ± 26.5 [SD]; no-event group [n = 21], 86.9 kPa ± 52.6; P = .01) and the stiffness ratio (event group, 0.7 ± 0.4; no-event group, 2.0 ± 1.4; P < .001) were lower in the event group than the no-event group at a mean follow-up of 449 days. AAA stiffness did not correlate with diameter in the event group (ρ = -0.06; P = .68) or the no-event group (ρ = -0.13; P = .32). AAA stiffness was inversely correlated with intraluminal thrombus area (ρ = -0.50; P = .01). Conclusion Lower abdominal aortic aneurysm stiffness and stiffness ratio measured with use of MR elastography was associated with aneurysmal events at a 15-month follow-up. © RSNA, 2022 See also the editorial by Sakuma in this issue.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Rupture , Elasticity Imaging Techniques , Thrombosis , Adult , Aged , Aged, 80 and over , Aorta, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/complications , Female , Humans , Male , Middle Aged , Proportional Hazards Models , Prospective Studies , Risk Factors , Thrombosis/complications
7.
J Magn Reson Imaging ; 56(6): 1722-1732, 2022 12.
Article in English | MEDLINE | ID: mdl-35289470

ABSTRACT

BACKGROUND: Magnetic resonance elastography (MRE) is an imaging technique that can noninvasively assess the shear properties of the intervertebral disc (IVD). Unlike the standard gradient recalled echo (GRE) MRE technique, a spin-echo echo-planar imaging (SE-EPI) sequence has the potential to improve imaging efficiency and patient compliance. PURPOSE: To validate the use of an SE-EPI sequence for MRE of the IVD compared against the standard GRE sequence. STUDY TYPE: Cross-over. SUBJECTS: Twenty-eight healthy volunteers (15 males and 13 females, age range: 19-55). FIELD STRENGTH/SEQUENCE: 3 T; GRE, SE-EPI with breath holds (SE-EPI-BH) and SE-EPI with free breathing (SE-EPI-FB) MRE sequences. ASSESSMENT: MRE-derived shear stiffnesses were calculated via principal frequency analysis. SE-EPI derived shear stiffness and octahedral shear strain signal-to-noise ratios (OSS-SNR) were compared against those derived using the GRE sequence. The reproducibility and repeatability of SE-EPI stiffness measurements were determined. Shear stiffness was evaluated in the nucleus pulposus (NP) and annulus fibrosus (AF) regions of the disc. Scan times between sequences were compared. STATISTICAL TESTS: Linear mixed models, Bland-Altman plots, and Lin's concordance correlation coefficients (CCCs) were used with P < 0.05 considered statistically significant. RESULTS: Good correlation was observed between shear stiffnesses derived from the SE-EPI sequences with those derived from the GRE sequence with CCC values greater than 0.73 and 0.78 for the NP and AF regions, respectively. OSS-SNR was not significantly different between GRE and SE-EPI sequences (P > 0.05). SE-EPI sequences generated highly reproducible and repeatable stiffness measurements with CCC values greater than 0.97 in the NP and AF regions and reduced scan time by at least 51% compared to GRE. SE-EPI-BH and SE-EPI-FB stiffness measurements were similar with CCC values greater than 0.98 for both regions. DATA CONCLUSION: SE-EPI-based MRE-derived stiffnesses were highly reproducible and repeatable and correlated with current standard GRE MRE-derived stiffness estimates while reducing scan times. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Subject(s)
Elasticity Imaging Techniques , Intervertebral Disc , Male , Female , Humans , Young Adult , Adult , Middle Aged , Elasticity Imaging Techniques/methods , Echo-Planar Imaging/methods , Reproducibility of Results , Signal-To-Noise Ratio , Intervertebral Disc/diagnostic imaging , Magnetic Resonance Imaging/methods
8.
NMR Biomed ; 35(6): e4685, 2022 06.
Article in English | MEDLINE | ID: mdl-34967060

ABSTRACT

Cardiac diffusion tensor imaging (DTI) is an emerging technique for the in vivo characterisation of myocardial microstructure, and there is a growing need for its validation and standardisation. We sought to establish the accuracy, precision, repeatability and reproducibility of state-of-the-art pulse sequences for cardiac DTI among 10 centres internationally. Phantoms comprising 0%-20% polyvinylpyrrolidone (PVP) were scanned with DTI using a product pulsed gradient spin echo (PGSE; N = 10 sites) sequence, and a custom motion-compensated spin echo (SE; N = 5) or stimulated echo acquisition mode (STEAM; N = 5) sequence suitable for cardiac DTI in vivo. A second identical scan was performed 1-9 days later, and the data were analysed centrally. The average mean diffusivities (MDs) in 0% PVP were (1.124, 1.130, 1.113) x 10-3  mm2 /s for PGSE, SE and STEAM, respectively, and accurate to within 1.5% of reference data from the literature. The coefficients of variation in MDs across sites were 2.6%, 3.1% and 2.1% for PGSE, SE and STEAM, respectively, and were similar to previous studies using only PGSE. Reproducibility in MD was excellent, with mean differences in PGSE, SE and STEAM of (0.3 ± 2.3, 0.24 ± 0.95, 0.52 ± 0.58) x 10-5  mm2 /s (mean ± 1.96 SD). We show that custom sequences for cardiac DTI provide accurate, precise, repeatable and reproducible measurements. Further work in anisotropic and/or deforming phantoms is warranted.


Subject(s)
Diffusion Tensor Imaging , Heart , Anisotropy , Diffusion Tensor Imaging/methods , Heart/diagnostic imaging , Phantoms, Imaging , Reproducibility of Results
9.
Magn Reson Med ; 87(1): 236-248, 2022 01.
Article in English | MEDLINE | ID: mdl-34463400

ABSTRACT

PURPOSE: Lung stiffness alters with many diseases; therefore, several MR elastography (MRE) studies were performed earlier to investigate the stiffness of the right lung during breathhold at residual volume and total lung capacity. The aims of this study were 1) to estimate shear stiffness of the lungs using MRE under free breathing and demonstrate the measurements' repeatability and reproducibility, and 2) to compare lung stiffness under free breathing to breathhold and as a function of age and gender. METHODS: Twenty-five healthy volunteers were scanned on a 1.5 Tesla MRI scanner. Spin-echo dual-density spiral and a spin-echo EPI MRE sequences were used to measure shear stiffness of the lungs during free breathing and breathhold at midpoint of tidal volume, respectively. Concordance correlation coefficient and Bland-Altman analyses were performed to determine the repeatability and reproducibility of the spin-echo dual-density spiral-derived shear stiffness. Repeated measures analyses of variances were used to investigate differences in shear stiffness between spin-echo dual-density spiral and spin-echo EPI, right and left lungs, males and females, and different age groups. RESULTS: Free-breathing MRE sequence was highly repeatable and reproducible (concordance correlation coefficient > 0.86 for both lungs). Lung stiffness was significantly lower in breathhold than in free breathing (P < .001), which can be attributed to potential stress relaxation of lung parenchyma or breathhold inconsistencies. However, there was no significant difference between different age groups (P = .08). The left lung showed slightly higher stiffness values than the right lung (P = .14). There is no significant difference in lung stiffness between genders. CONCLUSION: This study demonstrated the feasibility of free-breathing lung MRE with excellent repeatability and reproducibility. Stiffness changes with age and during the respiratory cycle. However, gender does not influence lungs stiffness.


Subject(s)
Elasticity Imaging Techniques , Echo-Planar Imaging , Female , Humans , Lung/diagnostic imaging , Magnetic Resonance Imaging , Male , Reproducibility of Results
10.
Magn Reson Imaging Clin N Am ; 29(4): 617-630, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34717849

ABSTRACT

Magnetic resonance elastography (MRE) is an emerging noninvasive technique, an alternative to palpation for quantitative assessment of biomechanical properties of tissue. In MRE, tissue stiffness information is obtained by a 3-step process, propagating mechanical waves in the tissues, measuring the wave propagation using modified magnetic resonance (MR) pulse sequences, and generating the quantitative stiffness maps from the MR images. MRE is clinically used in patients with liver diseases, whereas its applications in other organs are still being investigated. At present, the pediatric studies are in the initial stage and preliminary results promise to provide additional information about tissue characteristics.


Subject(s)
Elasticity Imaging Techniques , Liver Diseases , Brain/diagnostic imaging , Child , Humans , Magnetic Resonance Imaging
11.
Phys Med Biol ; 66(16)2021 08 02.
Article in English | MEDLINE | ID: mdl-34261056

ABSTRACT

Direct inversion (DI) derives tissue shear modulus by inverting the Helmholtz equation. However, conventional DI is sensitive to data quality due to the ill-posed nature of Helmholtz inversion and thus providing reliable stiffness estimation can be challenging. This becomes more problematic in the case of estimating shear stiffness of the lung in which the low tissue density and short T2* result in considerably low signal-to-noise ratio during lung MRE. In the present study, we propose to perform MRE inversion by compressive recovery (MICRo). Such a technique aims to improve the numerical stability and the robustness to data noise of Helmholtz inversion by using prior knowledge on data noise and transform sparsity of the stiffness map. The developed inversion strategy was first validated in simulated phantoms with known stiffness. Next, MICRo was compared to the standard clinical multi-modal DI (MMDI) method forin vivoliver MRE in healthy subjects and patients with different stages of liver fibrosis. After establishing the accuracy of MICRo, we demonstrated the robustness of the proposed technique against data noise in lung MRE with healthy subjects. In simulated phantoms with single-directional or multi-directional waves, MICRo outperformed DI with Romano filter or Savitsky and Golay filter, especially when the stiffness and/or noise level was high. In hepatic MRE application, agreement was observed between MICRo and MMDI. Measuringin vivolung stiffness, MICRo demonstrated its advantages over filtered DI by yielding stable stiffness estimation at both residual volume and total lung capacity. These preliminary results demonstrate the potential value of the proposed technique and also warrant further investigation in a larger clinical population.


Subject(s)
Elasticity Imaging Techniques , Healthy Volunteers , Humans , Liver/diagnostic imaging , Magnetic Resonance Imaging , Phantoms, Imaging
12.
Magn Reson Med ; 85(5): 2377-2390, 2021 05.
Article in English | MEDLINE | ID: mdl-33296103

ABSTRACT

Magnetic resonance elastography (MRE) is a phase contrast-based MRI technique that can measure displacement due to propagating mechanical waves, from which material properties such as shear modulus can be calculated. Magnetic resonance elastography can be thought of as quantitative, noninvasive palpation. It is increasing in clinical importance, has become widespread in the diagnosis and staging of liver fibrosis, and additional clinical applications are being explored. However, publications have reported MRE results using many different parameters, acquisition techniques, processing methods, and varied nomenclature. The diversity of terminology can lead to confusion (particularly among clinicians) about the meaning of and interpretation of MRE results. This paper was written by the MRE Guidelines Committee, a group formalized at the first meeting of the ISMRM MRE Study Group, to clarify and move toward standardization of MRE nomenclature. The purpose of this paper is to (1) explain MRE terminology and concepts to those not familiar with them, (2) define "good practices" for practitioners of MRE, and (3) identify opportunities to standardize terminology, to avoid confusion.


Subject(s)
Elasticity Imaging Techniques , Humans , Liver Cirrhosis/diagnostic imaging , Magnetic Resonance Imaging
13.
NMR Biomed ; 34(1): e4420, 2021 01.
Article in English | MEDLINE | ID: mdl-33021342

ABSTRACT

INTRODUCTION: Magnetic resonance elastography (MRE)-derived aortic stiffness is a potential biomarker for multiple cardiovascular diseases. Currently, gradient-recalled echo (GRE) MRE is a widely accepted technique to estimate aortic stiffness. However, multi-slice GRE MRE requires multiple breath-holds (BHs), which can be challenging for patients who cannot consistently hold their breath. The aim of this study was to investigate the feasibility of a multi-slice spin-echo echo-planar imaging (SE-EPI) MRE sequence for quantifying in vivo aortic stiffness using a free-breathing (FB) protocol and a single-BH protocol. METHOD: On Scanner 1, 25 healthy subjects participated in the validation of FB SE-EPI against FB GRE. On Scanner 2, another 15 healthy subjects were recruited to compare FB SE-EPI with single-BH SE-EPI. Among all volunteers, five participants were studied on both scanners to investigate the inter-scanner reproducibility of FB SE-EPI aortic MRE. Bland-Altman analysis, Lin's concordance correlation coefficient (LCCC) and coefficient of variation (COV) were evaluated. The phase-difference signal-to-noise ratios (PD SNR) were compared. RESULTS: Aortic MRE using FB SE-EPI and FB GRE yielded similar stiffnesses (paired t-test, P = 0.19), with LCCC = 0.97. The FB SE-EPI measurements were reproducible (intra-scanner LCCC = 0.96) and highly repeatable (LCCC = 0.99). The FB SE-EPI MRE was also reproducible across different scanners (inter-scanner LCCC = 0.96). Single-BH SE-EPI scans yielded similar stiffness to FB SE-EPI scans (LCCC = 0.99) and demonstrated a low COV of 2.67% across five repeated measurements. CONCLUSION: Multi-slice SE-EPI aortic MRE using an FB protocol or a single-BH protocol is reproducible and repeatable with advantage over multi-slice FB GRE in reducing acquisition time. Additionally, FB SE-EPI MRE provides a potential alternative to BH scans for patients who have challenges in holding their breath.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Cardiac-Gated Imaging Techniques/methods , Elasticity Imaging Techniques/methods , Magnetic Resonance Imaging/methods , Vascular Stiffness , Aorta, Abdominal/physiology , Cardiac-Gated Imaging Techniques/instrumentation , Echo-Planar Imaging/instrumentation , Echo-Planar Imaging/methods , Elasticity Imaging Techniques/instrumentation , Feasibility Studies , Humans , Magnetic Resonance Imaging/instrumentation , Reference Values , Reproducibility of Results , Respiration , Signal-To-Noise Ratio
14.
Invest Radiol ; 55(7): 463-472, 2020 07.
Article in English | MEDLINE | ID: mdl-32520516

ABSTRACT

OBJECTIVES: Using maximum diameter of an abdominal aortic aneurysm (AAA) alone for management can lead to delayed interventions or unnecessary urgent repairs. Abdominal aortic aneurysm stiffness plays an important role in its expansion and rupture. In vivo aortic magnetic resonance elastography (MRE) was developed to spatially measure AAA stiffness in previous pilot studies and has not been thoroughly validated and evaluated for its potential clinical value. This study aims to evaluate noninvasive in vivo aortic MRE-derived stiffness in an AAA porcine model and investigate the relationships between MRE-derived AAA stiffness and (1) histopathology, (2) uniaxial tensile test, and (3) burst testing for assessing MRE's potential in evaluating AAA rupture risk. MATERIALS AND METHODS: Abdominal aortic aneurysm was induced in 31 Yorkshire pigs (n = 226 stiffness measurements). Animals were randomly divided into 3 cohorts: 2-week, 4-week, and 4-week-burst. Aortic MRE was sequentially performed. Histopathologic analyses were performed to quantify elastin, collagen, and mineral densities. Uniaxial tensile test and burst testing were conducted to measure peak stress and burst pressure for assessing the ultimate wall strength. RESULTS: Magnetic resonance elastography-derived AAA stiffness was significantly higher than the normal aorta. Significant reduction in elastin and collagen densities as well as increased mineralization was observed in AAAs. Uniaxial tensile test and burst testing revealed reduced ultimate wall strength. Magnetic resonance elastography-derived aortic stiffness correlated to elastin density (ρ = -0.68; P < 0.0001; n = 60) and mineralization (ρ = 0.59; P < 0.0001; n = 60). Inverse correlations were observed between aortic stiffness and peak stress (ρ = -0.32; P = 0.0495; n = 38) as well as burst pressure (ρ = -0.55; P = 0.0116; n = 20). CONCLUSIONS: Noninvasive in vivo aortic MRE successfully detected aortic wall stiffening, confirming the extracellular matrix remodeling observed in the histopathologic analyses. These mural changes diminished wall strength. Inverse correlation between MRE-derived aortic stiffness and aortic wall strength suggests that MRE-derived stiffness can be a potential biomarker for clinically assessing AAA wall status and rupture potential.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Elasticity Imaging Techniques , Animals , Collagen/metabolism , Disease Models, Animal , Elastin/metabolism , Swine , Vascular Calcification/diagnostic imaging , Vascular Stiffness
15.
NMR Biomed ; 33(4): e4252, 2020 04.
Article in English | MEDLINE | ID: mdl-31971301

ABSTRACT

To design and validate a rapid Simultaneous Multi-slice (SMS) Magnetic Resonance Elastography technique (MRE), which combines SMS acquisition, in-plane undersampling and an existing rapid Magnetic Resonance Elastography (MREr) scheme to allow accelerated data acquisition in healthy volunteers and comparison against MREr. SMS-MREr sequence was developed by incorporating SMS acquisition scheme into an existing MREr sequence that accelerates MRE acquisition by acquiring data during opposite phases of mechanical vibrations. The MREr sequence accelerated MRE acquisition by acquiring data during opposite phases of mechanical vibrations. Liver MRE was performed on 23 healthy subjects using MREr and SMS-MREr sequences, and mean stiffness values were obtained for manually drawn regions of interest. Linear correlation and agreement between MREr- and SMS-MREr-based stiffness values were investigated. SMS-MREr reduced the scan time by half relative to MREr, and allowed acquisition of four-slice MRE data in a single 17-second breath-hold. Visual comparison suggested agreement between MREr and SMS-MREr elastograms. A Pearson's correlation of 0.93 was observed between stiffness values derived from MREr and SMS-MREr. Bland-Altman analysis demonstrated good agreement, with -0.08 kPa mean bias and narrow limits of agreement (95% CI: 0.23 to -0.39 kPa) between stiffness values obtained using MREr and SMS-MREr. SMS can be combined with other fast MRE approaches to achieve further acceleration. This pushes the limit on the acceleration that can be achieved in MRE acquisition, and makes it possible to conduct liver MRE exams in a single breath-hold.


Subject(s)
Elasticity Imaging Techniques , Liver/diagnostic imaging , Magnetic Resonance Imaging , Adult , Aged , Biomechanical Phenomena , Female , Humans , Liver/physiology , Male , Middle Aged , Phantoms, Imaging , Reproducibility of Results , Signal-To-Noise Ratio , Young Adult
16.
NMR Biomed ; 33(4): e4237, 2020 04.
Article in English | MEDLINE | ID: mdl-31889353

ABSTRACT

Stiffness plays an important role in diagnosing renal fibrosis. However, kidney stiffness is altered by perfusion changes in many kidney diseases. Therefore, the aim of the current study is to determine the correlation of kidney stiffness with water intake. We hypothesize that kidney stiffness will increase with 1 L of water intake due to increased water perfusion to the kidneys. Additionally, stiffness of the kidneys will correlate with apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values before and after water intake. A 3 T MRI scanner was used to perform magnetic resonance elastography and diffusion tensor imaging of the kidneys on 24 healthy subjects (age range: 22-66 years) before and after water intake of 1 L. A 3D T1-weighted bladder scan was also performed to measure bladder volume before and after water intake. A paired t-test was performed to evaluate the effect of water intake on the stiffness of kidneys, in addition to bladder volume. A Spearman correlation test was performed to determine the association between stiffness, bladder volume, ADC and FA values of both kidneys before and after water intake. The results show a significant increase in stiffness in different regions of the kidney (ie, percentage increase ranged from 3.6% to 7.5%) and bladder volume after water intake (all P < 0.05). A moderate significant negative correlation was observed between change in kidney stiffness and bladder volume (concordance correlation coefficient = -0.468, P < 0.05). No significant correlation was observed between stiffness and ADC or FA values before and after water intake in both kidneys (P > 0.05). Water intake caused a significant increase in the stiffness of the kidneys. The negative correlation between the change in kidney stiffness and bladder volume, before and after water intake, indicates higher perfusion pressure in the kidneys, leading to increased stiffness.


Subject(s)
Elasticity Imaging Techniques , Kidney/diagnostic imaging , Kidney/physiology , Magnetic Resonance Imaging , Perfusion , Water/chemistry , Adult , Aged , Biomechanical Phenomena , Diffusion Tensor Imaging , Female , Humans , Male , Middle Aged , Spin Labels , Young Adult
17.
NMR Biomed ; 32(11): e4141, 2019 11.
Article in English | MEDLINE | ID: mdl-31329347

ABSTRACT

The purpose of this study is 1) to demonstrate reproducibility of spin echo-echo planar imaging (SE-EPI) magnetic resonance elastography (MRE) to estimate kidney stiffness; and 2) to compare SE-EPI MRE and gradient recalled echo (GRE) MRE-derived stiffness estimations in various anatomical regions of the kidney. Kidney MRE was performed on 33 healthy subjects (8 for SE-EPI MRE reproducibility and 25 for comparison with GRE MRE; age range: 22-66 years) in a 3 T MRI scanner. To demonstrate SE-EPI MRE reproducibility, subjects were scanned for the first scan and then asked to leave the scan room and repositioned again for the second (repeat) scan. Similar set-up was used for GRE MRE as well. The displacement data was then processed to obtain overall stiffness estimates of the kidney. Concordance correlation analyses were performed to determine SE-EPI MRE reproducibility and agreement between GRE MRE and SE-EPI MRE derived stiffness. A high concordance correlation (ρc  = 0.95; p-value<0.0001) was obtained for SE-EPI MRE reproducibility. Good concordance correlation was observed (ρc  = 0.84; p < 0.0001 for both kidneys, ρc  = 0.91; p < 0.0001 for right kidney and ρc  = 0.78; p < 0.0001 for left kidney) between GRE MRE and SE-EPI MRE derived stiffness measurements. Paired t-test results showed that stiffness value of medulla was significantly (p < 0.0001) greater than cortex using SE-EPI MRE as well as GRE MRE. SE-EPI MRE was reproducible and good agreement was observed in MRE-derived stiffness measurements obtained using SE-EPI and GRE sequences. Therefore, SE-EPI can be used for kidney MRE applications.


Subject(s)
Elasticity Imaging Techniques , Kidney/diagnostic imaging , Magnetic Resonance Spectroscopy , Adult , Aged , Echo-Planar Imaging , Humans , Kidney/physiopathology , Middle Aged , Reproducibility of Results , Spin Labels , Young Adult
18.
Abdom Radiol (NY) ; 44(8): 2809-2821, 2019 08.
Article in English | MEDLINE | ID: mdl-31089778

ABSTRACT

Characteristic features of chronic pancreatitis (CP) may be absent on standard imaging studies. Quantitative Magnetic Resonance Imaging (MRI) techniques such as T1 mapping, extracellular volume (ECV) fraction, diffusion-weighted imaging (DWI) with apparent diffusion coefficient map (ADC), MR elastography (MRE), and T1-weighted signal intensity ratio (SIR) have shown promise for the diagnosis and grading severity of CP. However, radiologists still use the Cambridge classification which is based on traditional ductal imaging alone. There is an urgent need to develop new diagnostic criteria that incorporate both parenchymal and ductal features of CP seen by MRI/MRCP. Designed to fulfill this clinical need, we present the MINIMAP study, which was funded in September 2018 by the National Institutes of Health. This is a comprehensive quantitative MR imaging study which will be performed at multiple institutions in well-phenotyped CP patient cohorts. We hypothesize that quantitative MRI/MRCP features can serve as valuable non-invasive imaging biomarkers to detect and grade CP. We will evaluate the role of T1 relaxometry, ECV, T1-weighted gradient echo SIR, MRE, arteriovenous enhancement ratio, ADC, pancreas volume/atrophy, pancreatic fat fraction, ductal features, and pancreatic exocrine output following secretin stimulation in the assessment of CP. We will attempt to generate a multi-parametric pancreatic tissue fibrosis (PTF) scoring system. We anticipate that a quantitative scoring system may serve as a biomarker of pancreatic fibrosis; hence this imaging technique can be used in clinical practice as well as clinical trials to evaluate the efficacy of agents which may slow the progression or reverse measures of CP.


Subject(s)
Magnetic Resonance Imaging/methods , Pancreatitis/diagnostic imaging , Chronic Disease , Fibrosis , Humans , Multicenter Studies as Topic , United States
19.
NMR Biomed ; 32(7): e4102, 2019 07.
Article in English | MEDLINE | ID: mdl-31087728

ABSTRACT

Lung diseases are one of the leading causes of death worldwide, from which four million people die annually. Lung diseases are associated with changes in the mechanical properties of the lungs. Several studies have shown the feasibility of using magnetic resonance elastography (MRE) to quantify the lungs' shear stiffness. The aim of this study is to investigate the reproducibility and repeatability of lung MRE, and its shear stiffness measurements, obtained using a modified spin echo-echo planar imaging (SE-EPI) MRE sequence. In this study, 21 healthy volunteers were scanned twice by repositioning the volunteers to image right lung both at residual volume (RV) and total lung capacity (TLC) to assess the reproducibility of lung shear stiffness measurements. Additionally, 19 out of the 21 volunteers were scanned immediately without moving the volunteers to test the repeatability of the modified SE-EPI MRE sequence. A paired t-test was performed to determine the significant difference between stiffness measurements obtained at RV and TLC. Concordance correlation and Bland-Altman's analysis were performed to determine the reproducibility and repeatability of the SE-EPI MRE-derived shear stiffness measurements. The SE-EPI MRE sequence is highly repeatable with a concordance correlation coefficient (CCC) of 0.95 at RV and 0.96 at TLC. Similarly, the stiffness measurements obtained across all volunteers were highly reproducible with a CCC of 0.95 at RV and 0.92 at TLC. The mean shear stiffness of the lung at RV was 0.93 ± 0.22 kPa and at TLC was 1.41 ± 0.41 kPa. TLC showed a significantly higher mean shear stiffness (P = 0.0004) compared with RV. Lung MRE stiffness measurements obtained using the SE-EPI sequence were reproducible and repeatable, both at RV and TLC. Lung shear stiffness changes across respiratory cycle with significantly higher stiffness at TLC than RV.


Subject(s)
Elasticity Imaging Techniques , Lung/diagnostic imaging , Magnetic Resonance Imaging , Adult , Echo-Planar Imaging , Female , Humans , Image Processing, Computer-Assisted , Male , Reproducibility of Results , Residual Volume , Signal-To-Noise Ratio
20.
Magn Reson Med ; 82(2): 671-679, 2019 08.
Article in English | MEDLINE | ID: mdl-30957304

ABSTRACT

PURPOSE: Noninvasive measurement of mechanical properties of brain tissue using magnetic resonance elastography (MRE) has been a promising method for investigating neurologic disorders such as multiple sclerosis, hydrocephalus, and Alzheimer's. However, because of the regional and directional dependency of brain stiffness, estimating anisotropic stiffness is important. This study investigates isotropic and anisotropic stiffness as a function of age as well as the correlation between isotropic and anisotropic stiffness. METHODS: MRE and diffusion tensor imaging (DTI) were performed on 28 healthy subjects with age ranges between 18-62 y. Isotropic and anisotropic stiffness was measured and compared with age for different regions of interest such as the thalamus, corpus callosum, gray matter, white matter, and whole brain. RESULTS: Isotropic stiffness in gray matter (rs = -0.57; P = 0.001) showed a significant decrease with age. Anisotropic stiffness in gray matter showed a significant decrease with age in C11 through C66 and in the thalamus, only in C33 . Between anisotropic and isotropic stiffness, gray matter showed a significant positive correlation in C11 through C66 , C22 and C66 showed a significant negative correlation in the thalamus and whole brain, and C44 showed a negative correlation in the corpus callosum. No significant difference between genders was observed in any measurements. CONCLUSION: This study demonstrated a change in isotropic and anisotropic stiffness with age in different regions of the brain along with a correlation of anisotropic stiffness to isotropic stiffness.


Subject(s)
Brain/diagnostic imaging , Elasticity Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aging/physiology , Anisotropy , Elasticity Imaging Techniques/instrumentation , Equipment Design , Female , Humans , Magnetic Resonance Imaging/instrumentation , Male , Middle Aged , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...