Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Radiol Prot ; 42(4)2022 11 16.
Article in English | MEDLINE | ID: mdl-36347027

ABSTRACT

Sheltering is one of the countermeasures used to mitigate radiation exposure during nuclear power plant accidents. The effectiveness of sheltering for inhalation exposure is often expressed by the reduction factor, which is defined as the ratio of the indoor to the outdoor cumulative radioactivity concentrations or doses. The indoor concentration is mainly controlled by the air exchange rate, penetration factor, and indoor deposition rate. Meanwhile, the air exchange rate depends on surrounding environmental conditions: the wind speed, leakage area normalised by the floor area of the house, and gross building coverage ratio. In this study, the ranges of the uncertainty of the reduction factors for particles and iodine in reactive gas form were investigated under various environmental conditions, and sensitivity analyses were conducted to understand the parameter with the most influence on the uncertainty of the reduction factor. From the results of the uncertainty analyses, the calculated reduction factor was highly variable depending on the environmental condition and the airtightness of the houses. The median and 95th percentile of the reduction factors for the older houses were 0.5 and 0.9 for particles and 0.07 and 0.4 for iodine in reactive gas form, respectively and these ranges were smaller for newer houses. From the results of the sensitivity analyses, the wind speed was the most influential parameter determining the reduction factor. Additionally, the wind speed was less influential for the reduction factor in newer houses.


Subject(s)
Air Pollution, Indoor , Iodine , Radiation Exposure , Air Pollution, Indoor/analysis , Uncertainty , Housing , Radiation Exposure/analysis
2.
J Radiol Prot ; 41(3)2021 Aug 19.
Article in English | MEDLINE | ID: mdl-34409943

ABSTRACT

Sheltering is one of the countermeasures for protection against radiation exposures in nuclear accidents. The effectiveness of sheltering is often expressed by the reduction factor, that is the ratio of the indoor to the outdoor cumulative radioactivity concentrations or doses. The indoor concentration is mainly controlled by the air exchange rate, penetration factor, and indoor deposition rate. The penetration factor and indoor deposition rate depend on the surface and the materials and structure of windows and doors as it is these openings in the building envelope that control penetration. We investigated experimentally these parameters of I2and particles. The experiment was performed in two apartment houses, three single-family houses, and chambers. The obtained penetration factor ranged from 0.3 to 1 for particles of 0.3-1µm and 0.15-0.7 for I2depending on the air exchange rate. The indoor deposition rate for a house room ranged from 0.007 to 0.2 h-1for particles of 0.3-1µm and 0.2-1.5 h-1for I2.


Subject(s)
Air Pollution, Indoor , Iodine , Radiation Exposure , Air Pollution, Indoor/analysis , Environmental Monitoring , Housing , Japan
SELECTION OF CITATIONS
SEARCH DETAIL
...