Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Nucl Med ; 36(10): 913-921, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35913591

ABSTRACT

OBJECTIVE: While the use of biomarkers for the detection of early and preclinical Alzheimer's Disease has become essential, the need to wait for over an hour after injection to obtain sufficient image quality can be challenging for patients with suspected dementia and their caregivers. This study aimed to develop an image-based deep-learning technique to generate delayed uptake patterns of amyloid positron emission tomography (PET) images using only early-phase images obtained from 0-20 min after radiotracer injection. METHODS: We prepared pairs of early and delayed [11C]PiB dynamic images from 253 patients (cognitively normal n = 32, fronto-temporal dementia n = 39, mild cognitive impairment n = 19, Alzheimer's disease n = 163) as a training dataset. The neural network was trained with the early images as the input, and the output was the corresponding delayed image. A U-net convolutional neural network (CNN) and a conditional generative adversarial network (C-GAN) were used for the deep-learning architecture and the data augmentation methods, respectively. Then, an independent test data set consisting of early-phase amyloid PET images (n = 19) was used to generate corresponding delayed images using the trained network. Two nuclear medicine physicians interpreted the actual delayed images and predicted delayed images for amyloid positivity. In addition, the concordance of the actual delayed and predicted delayed images was assessed statistically. RESULTS: The concordance of amyloid positivity between the actual versus AI-predicted delayed images was 79%(κ = 0.60) and 79% (κ = 0.59) for each physician, respectively. In addition, the physicians' agreement rate was at 89% (κ = 0.79) when the same image was interpreted. And, the actual versus AI-predicted delayed images were not readily distinguishable (correct answer rate, 55% and 47% for each physician, respectively). The statistical comparison of the actual versus the predicted delated images indicated that the peak signal-to-noise ratio (PSNR) was 21.8 dB ± 2.2 dB, and the structural similarity index (SSIM) was 0.45 ± 0.04. CONCLUSION: This study demonstrates the feasibility of an image-based deep-learning framework to predict delayed patterns of Amyloid PET uptake using only the early phase images. This AI-based image generation method has the potential to reduce scan time for amyloid PET and increase the patient throughput, without sacrificing diagnostic accuracy for amyloid positivity.


Subject(s)
Alzheimer Disease , Amyloidosis , Deep Learning , Alzheimer Disease/diagnostic imaging , Amyloid , Humans , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/methods , Signal-To-Noise Ratio
2.
PET Clin ; 17(1): 57-64, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34809870

ABSTRACT

AI has been applied to brain molecular imaging for over 30 years. The past two decades, have seen explosive progress. AI applications span from operations processes such as attenuation correction and image generation, to disease diagnosis and prediction. As sophistication in AI software platforms increases, and the availability of large imaging data repositories become common, future studies will incorporate more multidimensional datasets and information that may truly reach "superhuman" levels in the field of brain imaging. However, even with a growing level of complexity, these advanced networks will still require human supervision for appropriate application and interpretation in medical practice.


Subject(s)
Artificial Intelligence , Brain , Brain/diagnostic imaging , Forecasting , Humans , Molecular Imaging , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...