Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 64(6): 06NT01, 2019 03 08.
Article in English | MEDLINE | ID: mdl-30695772

ABSTRACT

MR-only simulations provide pseudo-CT images which are segmented into 5 kinds of tissues from DIXON-based images. However, it is difficult to register pseudo-CT images to cone-beam CT (CBCT) images collected for image-guided radiation therapy (IGRT), because of the lack of contrasts among tissues. We validated gaps of IGRT between pseudo-CT or planning CT and CBCT for patients without implanted markers. We also propose calcification-assisted registration for MR-only simulation. We conducted retrospective analyses to verify the registration accuracy in 15 patients who underwent volumetric modulated arc therapy (VMAT) for prostate cancer. They underwent planning CT and pseudo-CT. Pseudo-CT images after deformable image registration (DIR) to planning CT images were rendered automatic pelvic bone matching to CBCT images. Patient positions on the pseudo-CT images after DIR were shifted on the basis of tissues around the prostate. We compared registration gaps between the images of planning CT and pseudo-CT with DIR, assuming that the tissue-based matching between the planning CT and CBCT was the gold standard. To the pseudo-CT images with DIR, calcifications detected on planning CT were added. We validated IGRT accuracy for a calcification-assisted registration. The absolute registration errors of the pseudo-CT, in comparison with the planning CT, were 0.34 ± 0.50 (lateral), 1.3 ± 1.3 (longitudinal), and 1.1 ± 1.0 mm (vertical). The absolute registration errors of the pseudo-CT with calcification contouring, in comparison with the planning CT, were 0.41 ± 1.0 (lateral), 0.87 ± 0.92 (longitudinal), and 0.74 ± 0.64 mm (vertical). Reduced absolute registration errors were observed in the proposed approach in the longitudinal (P < 0.01) and vertical (P < 0.01) dimensions when using calcification-assisted registration. The tissue-based registration using the MR-only simulation was not sufficient for use in patients with prostate cancer without implanted markers. The calcification-assisted registration might help to improve IGRT accuracy using MRI alone.


Subject(s)
Calcinosis/diagnosis , Cone-Beam Computed Tomography/methods , Fiducial Markers , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Aged , Calcinosis/diagnostic imaging , Humans , Male , Middle Aged , Prostatic Neoplasms/diagnostic imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...