Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Chromatogr Sci ; 53(5): 793-9, 2015.
Article in English | MEDLINE | ID: mdl-25644814

ABSTRACT

A specific stability-indicating reversed-phase high-performance liquid chromatographic method was developed and validated for the estimation of meclizine hydrochloride (MEC) in tablet dosage form. The HPLC method has shown adequate separation of MEC from their degradation products. The separation was achieved on a C8 (250 mm×4.6 mm×5 µm) column using a mobile phase composition of 0.2% triethylamine in water and methanol in the ratio of 65:35(pH adjusted to 3.0 with orthophosphoric acid) with a flow rate of 1 mL/min. The wavelength of a photo-diode array detector was kept at 229 nm. Stress studies were performed initially under milder conditions followed by stronger conditions so as to get sufficient degradation around 5-20%. There were six degradation products observed with adequate separation from the analyte peak. Among those detected degradation products, structures of four degradation products were verified by comparison with known impurities of meclizine analogs. The method was validated as per the International Conference on Harmonization (Q2) guidelines. The method was specific, selective, accurate and precise to quantify meclizine in the presence of degradation products.


Subject(s)
Anti-Allergic Agents/chemistry , Chromatography, High Pressure Liquid/methods , Chromatography, Reverse-Phase/methods , Meclizine/chemistry , Drug Stability , Molecular Structure , Tablets/chemistry
2.
J Chromatogr Sci ; 52(9): 1038-42, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24152592

ABSTRACT

A simple, selective, rapid, precise and economical reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for simultaneous estimation of atorvastatin calcium (ATV) and pioglitazone hydrochloride (PIO) from pharmaceutical formulation. The method is carried out on a C8 (25 cm × 4.6 mm i.d., 5 µm) column with a mobile phase consisting of acetonitrile (ACN):water (pH adjusted to 6.2 using o-phosphoric acid) in the ratio of 45:55 (v/v). The retention time of ATV and PIO is 4.1 and 8.1 min, respectively, with the flow rate of 1 mL/min with diode array detector detection at 232 nm. The linear regression analysis data from the linearity plot showed good linear relationship with a correlation coefficient (R(2)) value for ATV and PIO of 0.9998 and 0.9997 in the concentration range of 10-80 µg mL(-1), respectively. The relative standard deviation for intraday precision has been found to be <2.0%. The method is validated according to the ICH guidelines. The developed method is validated in terms of specificity, selectivity, accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for simultaneous estimation of these drugs in marketed dosage forms.


Subject(s)
Chromatography, High Pressure Liquid/methods , Chromatography, Reverse-Phase/methods , Dosage Forms , Heptanoic Acids/analysis , Pyrroles/analysis , Thiazolidinediones/analysis , Atorvastatin , Calibration , Drug Combinations , Hydrogen-Ion Concentration , Limit of Detection , Phosphoric Acids/chemistry , Pioglitazone , Reproducibility of Results
SELECTION OF CITATIONS