Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 112
Filter
3.
Heart Rhythm ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38762819

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) by His bundle pacing or left bundle branch area pacing (LBBAP) is incorporated into Heart Rhythm Society guidelines for the management of bradycardia and cardiac resynchronization therapy. Despite increasing adoption with both lumenless leads and stylet-driven leads, concerns regarding the feasibility and safety of the extraction of CSP leads remain. OBJECTIVE: The aim of the study was to report on the safety, feasibility, and clinical outcomes of the extraction of CSP leads. METHODS: Patients undergoing the extraction of CSP leads from 10 international centers were enrolled in this retrospective study. Data regarding indications, lead location, lead type, extraction tools, procedural success, complications, and reimplantation in the conduction system were collected. RESULTS: Overall, 341 patients (age 69 ± 15 years; female 34%; cardiomyopathy 46%; lead dwell time 22 ± 26 months) underwent the extraction of 224 His bundle pacing and 117 LBBAP leads (lumenless leads 321; stylet-driven leads 20). Complete procedural success was achieved in 338 (99%), while clinical success was 100% with retained distal fragments in 3 patients (1%). Among patients with a lead dwell time of >6 months (6-193 months; n = 226), manual extraction was successful in 198 (87%), mechanical tools in 22 (10%), and laser in 6 (3%). Femoral tools were necessary in 3 patients. Minor complications occurred in 7 patients (2.1%). CSP reimplantation was successful in 233 of 244 patients attempted (95%). CONCLUSION: The overall success rates of the extraction of CSP leads were very high (although the LBBAP lead dwell time was <3 years), with a low need for extraction tools and minimal complication. Reimplantation in the conduction system is feasible and safe.

4.
J Am Coll Cardiol ; 83(22): 2214-2232, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38811098

ABSTRACT

Arrhythmias frequently accompany heart failure and left ventricular dysfunction. Tachycardias, atrial fibrillation, and premature ventricular contractions can induce a reversible form of dilated cardiomyopathy (CM) known as arrhythmia-induced CM (AiCM). The intriguing question is why certain individuals are more susceptible to AiCM, despite similar arrhythmia burdens. The primary challenge is determining the extent of arrhythmias' contribution to left ventricular systolic dysfunction. AiCM should be considered in patients with a mean heart rate of >100 beats/min, atrial fibrillation, or a PVC burden of >10%. Confirmation of AiCM occurs when CM reverses upon eliminating the responsible arrhythmia. Therapy choice depends on the specific arrhythmia, patient comorbidities, and preferences. After left ventricular function is restored, ongoing follow-up is essential if an abnormal myocardial substrate persists. Accurate diagnosis and treatment of AiCM have the potential to enhance patients' quality of life, improve clinical outcomes, and reduce hospital admissions and overall health care costs.


Subject(s)
Arrhythmias, Cardiac , Humans , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Cardiomyopathies/etiology , Cardiomyopathies/therapy , Cardiomyopathies/physiopathology , Cardiomyopathies/diagnosis , Cardiomyopathy, Dilated/therapy , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated/etiology
6.
Article in English | MEDLINE | ID: mdl-37773559

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation of atrial fibrillation (AF); however, the results are suboptimal for persistent AF. The left atrial posterior wall (LAPW) is thought to be a major additional area in initiation and perpetuation of persistent AF. Therefore, adjunctive ablation of the posterior wall may reduce AF recurrence in patients with persistent AF. OBJECTIVE: The objective of this study was to compare outcomes of catheter ablation in patients with persistent AF using PVI alone versus a combination of PVI and LAPW isolation. METHODS: Literature search was conducted in PubMed, PubMed Central, Scopus, and Embase since inception to February 2023. Screening of studies was done via Covidence software. Risk of bias assessment was done using appropriate tools. Data extraction and a narrative synthesis were carried out accordingly. RESULTS: Ten studies were included, of which five were randomized controlled trials. PVI with LAPW ablation group had significantly lower recurrence of overall atrial tachyarrhythmia (OR 0.47, CI 0.32-0.70) and AF (OR 0.39, CI 0.23-0.69). In sensitivity analysis, freedom from atrial arrhythmias was noted to be significantly higher in the PVI with LAPW ablation group (OR 2.22, CI 1.36-3.64). However, there was no significant difference in occurrence of atrial flutter (OR 1.36, CI 0.86-2.14) or with periprocedural adverse events (OR 1.10, CI 0.60-1.99). CONCLUSION: LAPW ablation, in addition to PVI, significantly improves the rates of arrhythmia freedom and reduces the recurrence of overall atrial tachyarrhythmia. There was no significant difference in atrial flutter or periprocedural adverse events.

10.
J Am Coll Cardiol ; 81(12): 1192-1200, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36948737

ABSTRACT

Nonischemic cardiomyopathies are a frequent occurrence. The understanding of the mechanism(s) and triggers of these cardiomyopathies have led to improvement and even recovery of left ventricular function. Although chronic right ventricular pacing-induced cardiomyopathy has been recognized for many years, left bundle branch block and pre-excitation have been recently identified as potential reversible causes of cardiomyopathy. These cardiomyopathies share a similar abnormal ventricular propagation that can be recognized by a wide QRS duration with left bundle branch block pattern; thus, we coined the term abnormal conduction-induced cardiomyopathies. Such abnormal propagation results in an abnormal contractility that can only be recognized by cardiac imaging as ventricular dyssynchrony. Appropriate diagnosis and treatment will not only lead to improved left ventricular ejection fraction and functional class, but may also reduce morbidity and mortality. This review presents an update of the mechanisms, prevalence, incidence, and risk factors, as well as their diagnosis and management, while highlighting current gaps of knowledge.


Subject(s)
Bundle-Branch Block , Cardiomyopathies , Humans , Bundle-Branch Block/therapy , Stroke Volume , Ventricular Function, Left , Cardiac Conduction System Disease , Cardiomyopathies/diagnosis , Cardiomyopathies/epidemiology , Cardiomyopathies/etiology , Arrhythmias, Cardiac/complications , Treatment Outcome
11.
J Cardiovasc Electrophysiol ; 34(4): 900-907, 2023 04.
Article in English | MEDLINE | ID: mdl-36738139

ABSTRACT

INTRODUCTION: Radiofrequency ablation (RFA) utilizing half-normal saline (HNS) irrigation is a promising intervention to circumvent commonly encountered limitations during radiofrequency ablation of deep myocardial substrate. Few studies to date have analyzed the morphologic changes in the human myocardium following HNS RFA. METHODS AND RESULTS: Three patients with symptomatic ventricular tachycardia (VT) who underwent RFA with HNS irrigation underwent pathological specimen examination at time of autopsy or following native heart explant at the time of cardiac transplantation. Gross evaluation of the heart was performed fresh and after fixation in 10% formalin. A routine examination was performed with fixation in 10% formalin. Sections of lesioned tissue were paraffin embedded and evaluated using standard hematoxylin and eosin (H&E) staining. CONCLUSION: Irrigated RF ablation with HNS irrigant produces coagulative necrosis as well as several delayed histopathological changes with a deeper field of effective ablation. Transmurality may not be obtained in the ventricular myocardium with endocardial, epicardial, or sequential unipolar HNS ablation.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Humans , Saline Solution , Catheter Ablation/methods , Heart , Formaldehyde
12.
J Clin Med ; 12(2)2023 Jan 16.
Article in English | MEDLINE | ID: mdl-36675649

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is the most common cardiac arrhythmia associated with high morbidity and mortality. AF treatment is guided by a patient-provider risk-benefit discussion regarding drug versus ablation or combination. Thermal ablation has a high rate of adverse events compared to pulsed field ablation (PFA). In this systematic review, we aimed to determine the safety and efficacy of PFA. METHODS: The electronic search for relevant articles in English was completed in PubMed, PubMed Central, Cochrane library, Scopus, and Embase databases till July 2022. The screening was completed via the use of Covidence software. The risk of bias assessment and data extraction from the included studies was performed, and the narrative synthesis was performed accordingly. RESULTS: A total of six studies were selected for review and 1897 patients receiving PFA were involved in these studies. Our review was focused on pulmonary vein isolation success, major adverse events, and arrhythmia recurrence. Successful pulmonary vein isolation (PVI) was completed in 100% of cases except in two studies. In one of them, six out of seven patients (86%) in the epicardial cohort had successful PVI. In the MANIFEST-PF survey, the acute PVI success rate was 99.9%. The major complications were rare and included pericardial tamponade, vascular complications requiring surgery, and stroke. The atrial arrhythmia recurrence was higher in the thermal group than in the PFA group (39% vs. 11%). CONCLUSIONS: The success rate of PVI by PFA is high, and major adverse events are low. PFA is found to decrease the recurrence of atrial arrhythmia compared to thermal ablation. Substantial randomized controlled trials (RCTs) are needed to validate the efficacy and safety of PFA over conventional methods.

13.
J Interv Card Electrophysiol ; 66(8): 1807-1815, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36645578

ABSTRACT

BACKGROUND: Mapping and ablating atypical atrial flutters (AAFLs) have evolved greatly with advances in high-density 3D mapping systems over the last years. METHODS: The objectives are to evaluate the feasibility of AAFL catheter ablation based on high-density mapping and minimizing entrainment and to better characterize AAFL circuits. Consecutive patients who underwent AAFL ablation using the EnSite Precision™ system and HD Grid™ mapping catheter (Abbott, Chicago, IL) between 06/2018 and 1/2022 were included. Mitral isthmus-dependent and roof-dependent AAFLs were classified as conventional circuits. All other AAFL circuits were classified as non-conventional circuits and were defined based on the location of the critical isthmus. RESULTS: Sixty-two patients underwent AAFL ablation (mean age 68±11 years). A total of 95 AAFLs were mapped and 92 (97%) were successfully ablated. Fifty-three (85%) patients had a previous AF/AFL ablation. Forty-four (46%) AAFL circuits were classified as conventional and 51 (54%) as non-conventional. Conventional AAFL circuits had longer critical isthmuses (19.0±9.0 vs 10.8±6.3mm, p<0.001), a lower prevalence of slow conduction at the critical isthmus (59% vs 86%, p=0.005), and a longer radiofrequency time to AAFL termination (117±119 vs 51±66 s, p=0.002). Entrainment was attempted in 19 (20%) flutters and its use declined significantly over the study period. Procedural success rates remained high whether entrainment was used or not. Freedom of any atrial tachycardia was 65% over a follow-up of 13.8±9.0 months. CONCLUSIONS: AAFL catheter ablation can be achieved with high procedural success rate using a contemporary strategy based on high-density mapping alone. Non-conventional circuits are frequent and present unique electrophysiological characteristics.

14.
Article in English | MEDLINE | ID: mdl-36652082

ABSTRACT

BACKGROUND: The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data. METHODS: Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less. RESULTS: Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months. CONCLUSIONS: The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04767516 .

15.
JACC Clin Electrophysiol ; 8(12): 1500-1510, 2022 12.
Article in English | MEDLINE | ID: mdl-36543499

ABSTRACT

BACKGROUND: Takotsubo syndrome is associated with life threatening arrhythmias, and the apical ballooning pattern is characterized by a peculiar QT prolongation and particularly high-risk of arrhythmias. OBJECTIVES: The aim of the study was to determine the association of QT interval on electrocardiogram for ventricular arrhythmic complications in patients with apical ballooning Takotsubo syndrome in a diverse population at a large urban hospital in the U.S. METHODS: We reviewed 105 cases of apical ballooning Takotsubo syndrome in patients admitted between 2011 and 2017. Two cardiologists reviewed the electrocardiograms to measure QT interval, adjusted for rate using the Fridericia formula (QTCF), and ventricular arrhythmic complications during the hospitalization. Data are reported as median and interquartile range or number and percentage. RESULTS: Of the 105 patients, 86 (82%) were female, and 34 (32%) were self-reported Black or African American. The mean age was 65 years (range: 58-72 years). Left ventricular ejection fraction was 25% (range: 25%-35%). Heart rate was 101 beats/min (range: 83-121 beats/min). Ten (11%) patients experienced a ventricular arrhythmic complication and had significantly longer QTCF (470 [range: 422-543] milliseconds) than did those without complications (417 [range: 383-456] milliseconds, P = 0.031). The area under the curve for QTCF was 0.708 (95% CI: 0.536-0.880; P = 0.031). Twenty-eight (27%) patients had a QTCF ≥460 milliseconds and significantly more arrhythmic complications (21% vs 5%, odds ratio 4.997 [95% CI: 1.288-19.237], P = 0.021). QTCF was an independent predictor of ventricular arrhythmias: odds ratio 1.090 for each 10-millisecond increase in QTCF (95% CI: 1.004-1.183; P = 0.040, corrected for sex). CONCLUSIONS: In a diverse population of patients with apical ballooning Takotsubo syndrome admitted to a large urban hospital in the United States, QTCF at admission ≥460 milliseconds identifies patients at high risk for in-hospital arrhythmic complications. Further studies are needed to determine strategies aimed at shortening QT interval to potentially prevent life-threatening arrhythmic events.


Subject(s)
Long QT Syndrome , Takotsubo Cardiomyopathy , Humans , Female , Aged , Male , Takotsubo Cardiomyopathy/complications , Stroke Volume , Ventricular Function, Left , Long QT Syndrome/complications , Long QT Syndrome/epidemiology , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/complications , Hospitals
16.
Heart Rhythm ; 19(9): 1484-1490, 2022 09.
Article in English | MEDLINE | ID: mdl-35562056

ABSTRACT

BACKGROUND: The reported success rate of His-bundle pacing (HBP) in patients with infranodal atrioventricular (AV) conduction disease is only 52%-76%. The success rate of left bundle branch area pacing (LBBAP) in this cohort is not well studied. OBJECTIVE: The purpose of this study was to evaluate the feasibility, safety, and electrophysiological characteristics of LBBAP in patients with AV conduction disease. METHODS: Patients with AV conduction disease referred for pacemaker implantation at 2 centers between February 2019 and June 2021 were considered for LBBAP. Baseline demographic characteristics, procedural success rates, electrophysiological parameters, and complications were assessed. RESULTS: LBBAP was successful in 340 of 364 patients (93%). Mean age was 72 ± 13 years, and mean follow-up was 331 ± 244 days. Pacing indications were Mobitz I in 27 patients (7%), Mobitz II or 2:1 AV block or high-grade AV block in 94 patients (26%), complete heart block in 199 patients (55%), and sick sinus syndrome with isolated bundle branch block in 44 patients (12%). Left bundle branch block and right bundle branch block were present in 57 patients (16%) and 140 patients (38%), respectively. Procedural success rates did not differ between indications (92.6%, 93.6%, 92.9%, and 95%, respectively) or between patients with narrow (<120 ms) vs wide QRS (≥120 ms). Mean LBBAP threshold was 0.77 ± 0.34 V at 0.4 ms at implant and remained stable during follow-up. There were 4 (1.2%) acute LBBAP lead dislodgments. CONCLUSION: LBBAP is safe and feasible with high success rates for patients with AV conduction disease. In contrast to HBP, LBBAP success rates remain high over the entire spectrum of AV conduction disease, and lead parameters remain stable during follow-up.


Subject(s)
Atrioventricular Block , Aged , Aged, 80 and over , Atrioventricular Block/therapy , Bundle of His , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Electrocardiography , Humans , Middle Aged , Prospective Studies , Treatment Outcome
18.
Am J Cardiol ; 172: 40-47, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35365289

ABSTRACT

Electrical storm (ES) is a life-threatening condition that may lead to recurrent arrhythmias, need for ventricular mechanical support, and death. The study aimed to assess the burden of arrhythmia recurrence and in-hospital outcomes of patients admitted for ES in a large urban hospital. We performed a retrospective analysis of patients admitted with ventricular arrhythmias from January 2018 to June 2021 and identified 61 patients with ES, defined as 3 or more episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF) within 24 hours. We reviewed the in-hospital outcomes and compared outcomes between patients who had no recurrence of VT/VF after the first 24 hours (34 [56%]), those with recurrence of 1 or 2 episodes of VT/VF within a 24-hour period (15 [24%]), and patients with 3 or more recurrent VT/VF events consistent with recurrent ES after the first 24 hours (12 [20%]). Patients with recurrent ES had significantly higher in-hospital mortality as compared with those with recurrent VT/VF not meeting criteria for ES or no recurrences of VT/VF (3 [25%] vs 0 [0%] vs 0 [0%]; p = 0.002). Moreover, patients with recurrent ES also had higher rates of the combined end points of ventricular mechanical support and death (7 [58%] vs 1 [6%] vs 1 [3%], p <0.001), invasive mechanical ventilation and death (10 [83%] vs 2 [13%] vs 2 [6%], p <0.001), catheter ablation or death (12 [100%] vs 7 [47%] vs 12 [35%], p <0.001) and heart transplantation and death (3 [25%] vs 2 [13%] vs 0 [0%], p = 0.018). In conclusion, patients admitted with ES have a high risk of in-hospital recurrence, associated with extremely poor outcomes.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Arrhythmias, Cardiac/etiology , Defibrillators, Implantable/adverse effects , Humans , Recurrence , Retrospective Studies , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Treatment Outcome , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy
19.
Heart Rhythm ; 19(7): 1116-1123, 2022 07.
Article in English | MEDLINE | ID: mdl-35351624

ABSTRACT

BACKGROUND: Single-center studies have shown feasibility of conduction system pacing (CSP) via His-bundle pacing (HBP) or left bundle branch area pacing (LBBAP) in atrial fibrillation (AF) patients undergoing atrioventricular junction ablation (AVJA). OBJECTIVE: The purpose of this study was to compare outcomes in patients with HBP and LBBAP leads undergoing AVJA. METHODS: Consecutive patients with CSP leads referred for AVJA between October 2014 and May 2021 were included. Pacing lead characteristics, procedural characteristics, complications, and long-term outcomes were assessed. RESULTS: One hundred five AVJA procedures (55 HBP, 50 LBBAP) were performed in 98 patients (48 HBP, 50 LBBAP). The acute success rate of the AVJA procedure was 94% vs 100% (P = .11) in HBP vs LBBAP groups. Seven (14%) redo AVJA procedures were required in the HBP group. Mean procedural time (44 ± 24 min vs 34 ± 16 min; P = .02) and mean fluoroscopy time (16 ± 18 min vs 7 ± 6 min; P <.001) were significantly longer in the HBP vs LBBAP group. An acute rise in threshold was noted in 8 cases (14.5%), and 4 (8%) developed exit block after AVJA in HBP patients. Chronic HBP threshold ≥2.5 V was seen in 23 patients (48%), and 4 (8%) HBP leads were deactivated. CSP preserved ejection fraction (EF) in the overall cohort (N = 70; 53% ± 10% vs 55% ± 10%; P = .09) and significantly improved in those with reduced EF <50% at baseline (N = 16; 37% ± 7.6% vs 46% ± 13%; P = .02). CONCLUSION: AVJA in the presence of an LBBAP lead is associated with a higher success rate and fewer acute and chronic lead-related complications. CSP with either HBP or LBBAP preserves left ventricular systolic function in patients with refractory atrial fibrillation post AVJA.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Bundle of His , Cardiac Conduction System Disease , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Heart Conduction System , Humans , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...