Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
BMC Emerg Med ; 24(1): 43, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38486156

ABSTRACT

OBJECTIVES: In this study we aimed to explore EMCC triage of suspected and confirmed stroke patients to gain more knowledge about the initial phase of the acute stroke response chain. Accurate dispatch at the Emergency Medical Communication Center (EMCC) is crucial for optimal resource utilization in the prehospital service, and early identification of acute stroke is known to improve patient outcome. MATERIALS AND METHODS: We conducted a descriptive retrospective study based on data from the Emergency Department and EMCC records at a comprehensive stroke center in Oslo, Norway, during a six-month period (2019-2020). Patients dispatched with EMCC stroke criteria and/or discharged with a stroke diagnosis were included. We identified EMCC true positive, false positive and false negative stroke patients and estimated EMCC stroke sensitivity and positive predictive value (PPV). Furthermore, we analyzed prehospital time intervals and identified patient destinations to gain knowledge on ambulance services assessments. RESULTS: We included 1298 patients. EMCC stroke sensitivity was 77% (95% CI: 72 - 82%), and PPV was 16% (95% CI: 14 - 18%). EMCC false negative stroke patients experienced an increased median prehospital delay of 11 min (p < 0.001). Upon arrival at the scene, 68% of the EMCC false negative patients were identified as suspected stroke cases by the ambulance services. Similarly, 68% of the false positive stroke patients were either referred to a GP, out-of-hours GP acute clinic, local hospitals or left at the scene by the ambulance services, indicating that no obvious stroke symptoms were identified by ambulance personnel upon arrival at the scene. CONCLUSIONS: This study reveals a high EMCC stroke sensitivity and an extensive number of false positive stroke dispatches. By comparing the assessments made by both the EMCC and the ambulance service, we have identified specific patient groups that should be the focus for future research efforts aimed at improving the sensitivity and specificity of stroke recognition in the EMCC.


Subject(s)
Ambulances , Stroke , Humans , Triage , Retrospective Studies , Stroke/diagnosis , Stroke/therapy , Telephone
2.
Environ Res ; 175: 148-155, 2019 08.
Article in English | MEDLINE | ID: mdl-31125718

ABSTRACT

BACKGROUND: Terrestrial Trunked Radio (TETRA) is used for radiocommunications among the British police forces. OBJECTIVES: To investigate association of personal radio use and sickness absence among police officers and staff from the Airwave Health Monitoring Study. METHODS: Participant-level sickness absence records for 26 forces were linked with personal radio use for 32,102 participants. We used multivariable logistic regression to analyse TETRA usage in year prior to enrolment and sickness absence (lasting more than 7 or 28 consecutive days) in the following year and a zero-inflated negative binomial model for analyses of number of sickness absence episodes of any duration ('spells') over the same period. In secondary analyses, we looked at an extended period of observation among a sub-cohort with linked data over time, using Cox proportional hazards regression. RESULTS: Median personal radio use (year prior to enrolment) was 29.7 min per month (interquartile range 7.5, 64.7) among users. In the year following enrolment there were 25,655 sickness absence spells among 15,248 participants. There were similar risks of sickness absence lasting more than seven days among users and non-users, although among users risk was higher with greater use, odds ratio = 1.04 (95% confidence interval [CI] 1.02 to 1.06) per doubling of radio use. There was no association for sickness absence of more than 28 days. For sickness absence spells, risk was lower among users than non-users (incidence rate ratio = 0.91; 95% CI 0.75 to 1.11), again with higher risk among users for greater radio use. There was no association between radio use and sickness absence in secondary analyses. DISCUSSION: There were similar or lower risks of sickness absence in TETRA radio users compared with non-users. Among users, the higher risk of sickness absence with greater radio use may reflect working pattern differences among police personnel rather than effects of radiofrequency exposure.


Subject(s)
Police , Radio , Sick Leave , Humans , Occupational Exposure/statistics & numerical data , Police/statistics & numerical data , Radio/statistics & numerical data , Radio Waves/adverse effects , Sick Leave/statistics & numerical data
3.
J Clin Med ; 8(5)2019 May 22.
Article in English | MEDLINE | ID: mdl-31121817

ABSTRACT

Compressions during the insufflation phase of ventilations may cause severe pulmonary injury during cardiopulmonary resuscitation (CPR). Transthoracic impedance (TTI) could be used to evaluate how chest compressions are aligned with ventilations if the insufflation phase could be identified in the TTI waveform without chest compression artifacts. Therefore, the aim of this study was to determine whether and how the insufflation phase could be precisely identified during TTI. We synchronously measured TTI and airway pressure (Paw) in 21 consenting anaesthetised patients, TTI through the defibrillator pads and Paw by connecting the monitor-defibrillator's pressure-line to the endotracheal tube filter. Volume control mode with seventeen different settings were used (5-10 ventilations/setting): Six volumes (150-800 mL) with 12 min-1 frequency, four frequencies (10, 12, 22 and 30 min-1) with 400 mL volume, and seven inspiratory times (0.5-3.5 s ) with 400 mL/10 min-1 volume/frequency. Median time differences (quartile range) between timing of expiration onset in the Paw-line (PawEO) and the TTI peak and TTI maximum downslope were measured. TTI peak and PawEO time difference was 579 (432-723) m s for 12 min-1, independent of volume, with a negative relation to frequency, and it increased linearly with inspiratory time (slope 0.47, R 2 = 0.72). PawEO and TTI maximum downslope time difference was between -69 and 84 m s for any ventilation setting (time aligned). It was independent ( R 2 < 0.01) of volume, frequency and inspiratory time, with global median values of -47 (-153-65) m s , -40 (-168-68) m s and 20 (-93-128) m s , for varying volume, frequency and inspiratory time, respectively. The TTI peak is not aligned with the start of exhalation, but the TTI maximum downslope is. This knowledge could help with identifying the ideal ventilation pattern during CPR.

4.
Br J Cancer ; 120(3): 375-378, 2019 02.
Article in English | MEDLINE | ID: mdl-30585256

ABSTRACT

BACKGROUND: Radiofrequency electromagnetic fields (RF-EMF) from mobile phones have been classified as potentially carcinogenic. No study has investigated use of Terrestrial Trunked Radio (TETRA), a source of RF-EMF with wide occupational use, and cancer risks. METHODS: We investigated association of monthly personal radio use and risk of cancer using Cox proportional hazards regression among 48,518 police officers and staff of the Airwave Health Monitoring Study in Great Britain. RESULTS: During median follow-up of 5.9 years, 716 incident cancer cases were identified. Among users, the median of the average monthly duration of use in the year prior to enrolment was 30.5 min (inter-quartile range 8.1, 68.1). Overall, there was no association between personal radio use and risk of all cancers (hazard ratio [HR] = 0.98, 95% confidence interval [CI]: 0.93, 1.03). For head and neck cancers HR = 0.72 (95% CI: 0.30, 1.70) among personal radio users vs non-users, and among users it was 1.06 (95% CI: 0.91, 1.23) per doubling of minutes of personal radio use. CONCLUSIONS: With the limited follow-up to date, we found no evidence of association of personal radio use with cancer risk. Continued follow-up of the cohort is warranted.


Subject(s)
Electromagnetic Fields/adverse effects , Environmental Exposure/adverse effects , Head and Neck Neoplasms/epidemiology , Radio Waves/adverse effects , Cell Phone , Ethnicity , Female , Head and Neck Neoplasms/etiology , Humans , Male , Police , United Kingdom/epidemiology
5.
Environ Res ; 167: 169-174, 2018 11.
Article in English | MEDLINE | ID: mdl-30014898

ABSTRACT

BACKGROUND: The Airwave Health Monitoring Study aims to investigate the possible long-term health effects of Terrestrial Trunked Radio (TETRA) use among the police forces in Great Britain. Here, we investigate whether objective data from the network operator could be used to correct for misreporting in self-reported data and expand the radio usage availability in our cohort. METHODS: We estimated average monthly usage of personal radio in the 12 months prior to enrolment from a missing value imputation model and evaluated its performance against objective and self-reported data. Factors associated with TETRA radio usage variables were investigated using Chi-square tests and analysis of variance. RESULTS: The imputed data were better correlated with objective than self-reported usage (Spearman correlation coefficient = 0.72 vs. 0. 52 and kappa 0.56 [95% confidence interval 0.55, 0.56] vs. 0.46 [0.45, 0.47]), although the imputation model tended to under-estimate use for higher users. Participants with higher personal radio usage were more likely to be younger, men vs. women and officer vs. staff. The median average monthly usage level for the entire cohort was estimated to be 29.3 min (95% CI: [7.2, 66.6]). CONCLUSION: The availability of objective personal radio records for a large proportion of users allowed us to develop a robust imputation model and hence obtain personal radio usage estimates for ~50,000 participants. This substantially reduced exposure misclassification compared to using self-reported data and will allow us to carry out analyses of TETRA usage for the entire cohort in future work.


Subject(s)
Data Accuracy , Occupational Exposure , Police , Radio Waves , Female , Humans , Male , Self Report , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL
...