Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 94(2): 023510, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36859055

ABSTRACT

A signal separation system is constructed on the multi-pass Thomson scattering system of Heliotron J to solve the problem of overlapping scattered light signals for the electron temperature anisotropy measurement. The phenomenon of overlapping scattered light signals is relieved by operating the signal separation system. A Raman scattering experiment is undertaken to verify the separation effect of the signal separation system. Two scattered light signals corresponding to two adjacent incidences of one laser shot were extended to 104 ns. Moreover, we applied the multi-pass Thomson scattering system with signal separation system to the electron temperature anisotropy measurement. No anisotropy was observed within the error bars in the initial experiment.

2.
Rev Sci Instrum ; 94(1): 013503, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36725559

ABSTRACT

This paper proposes a design of dual scattering angles multi-path Thomson scattering system with a signal separation function to solve the overlapping phenomenon of scattered light signals and to increase the measurement accuracy for the investigation of anisotropic electron velocity distribution. Furthermore, an optical path design is proposed to demonstrate how overlapping scattered light signals can be separated by setting the optical path in a limited room with a compact layout, which makes the incident interval between two overlapping scattered light signals 1.7 times longer than that of our current system. The specific position of each optical component existing in the system is determined via a Gaussian beam analysis to avoid damage caused by overexpansion of spot size with the application of two cooperating image relay systems. Conversely, a polychromator is optimized by resetting the pass waveband of the interference filter combination to achieve high accuracy in electron temperature (Te) measurement corresponding to two scattering angles simultaneously.

3.
Sci Rep ; 12(1): 15567, 2022 Sep 23.
Article in English | MEDLINE | ID: mdl-36151115

ABSTRACT

For plasma spectroscopy, Stokes spectropolarimetry is used as a method to spatially invert the viewing-chord-integrated spectrum on the basis of the correspondence between the given magnetic field profile along the viewing chord and the Zeeman effect appearing on the spectrum. Its application to fusion-related toroidal plasmas is, however, limited owing to the low spatial resolution as a result of the difficulty in distinguishing between the Zeeman and Doppler effects. To resolve this issue, we increased the relative magnitude of the Zeeman effect by observing a near-infrared emission line on the basis of the greater wavelength dependence of the Zeeman effect than of the Doppler effect. By utilizing the increased Zeeman effect, we are able to invert the measured spectrum with a high spatial resolution by Monte Carlo particle transport simulation and by reproducing the measured spectra with the semiempirical adjustment of the recycling condition at the first walls. The inversion result revealed that when the momentum exchange collisions of atoms are negligible, the velocity distribution of core-fueling atoms is mainly determined by the initial distribution at the time of recycling. The inversion result was compared with that obtained using a two-point emission model used in previous studies. The latter approximately reflects the parameters of atoms near the emissivity peak.

4.
Rev Sci Instrum ; 81(10): 10D532, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033887

ABSTRACT

A new high repetition rate Nd:YAG Thomson scattering system has been designed for the Heliotron J helical device. The main purpose of installing the new Thomson scattering system is an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with ∼10 mm resolution. Two high repetition Nd:YAG lasers (>550 mJ at 50 Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time interval. Scattered light is collected with a large concave mirror (D=800 mm, f/2.25) with a solid angle of ∼100 msr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected (scattering angle is 20°). Model simulation of the polychromator shows the measurable electron temperature and density range are from 10 eV to 10 keV, >5×10(18) m(-3) within 3% error for the temperature measurement, respectively.

5.
Rev Sci Instrum ; 79(10): 10E301, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044463

ABSTRACT

Imaging bolometers utilize an infrared (IR) video camera to measure the change in temperature of a thin foil exposed to the plasma radiation, thereby avoiding the risks of conventional resistive bolometers related to electric cabling and vacuum feedthroughs in a reactor environment. A prototype of the IR imaging video bolometer (IRVB) has been installed and operated on the JT-60U tokamak demonstrating its applicability to a reactor environment and its ability to provide two-dimensional measurements of the radiation emissivity in a poloidal cross section. In this paper we review this development and present the first results of an upgraded version of this IRVB on JT-60U. This upgrade utilizes a state-of-the-art IR camera (FLIR/Indigo Phoenix-InSb) (3-5 microm, 256 x 360 pixels, 345 Hz, 11 mK) mounted in a neutron/gamma/magnetic shield behind a 3.6 m IR periscope consisting of CaF(2) optics and an aluminum mirror. The IRVB foil is 7 cm x 9 cm x 5 microm tantalum. A noise equivalent power density of 300 microW/cm(2) is achieved with 40 x 24 channels and a time response of 10 ms or 23 microW/cm(2) for 16 x 12 channels and a time response of 33 ms, which is 30 times better than the previous version of the IRVB on JT-60U.

SELECTION OF CITATIONS
SEARCH DETAIL
...