1.
Clin Chem Lab Med ; 57(12): 1988-1998, 2019 Nov 26.
Article in English | MEDLINE | ID: mdl-31339851

ABSTRACT

Background Alinity hq (Abbott) is a new high-throughput hematology analyzer that exclusively employs optical principles for detecting and enumerating blood cells. It reports 29 parameters, including a six-part white blood cell (WBC) differential. The aim of this multicenter study was to evaluate the analytical and clinical performance of the Alinity hq. Methods Complete blood count (CBC) results and morphological flagging were compared to that of CELL-DYN Sapphire (Abbott) and 2 × 200-cell manual differential results, on 1473 whole-blood samples from a well-defined patient population from three different clinical laboratories in the Netherlands. In addition, within-run and within-laboratory precision, linearity, limit of quantitation, carryover and sample stability were assessed. External quality assessment samples were also evaluated. Results Data analysis demonstrated strong concordance of Alinity hq results with those of CELL-DYN Sapphire for all CBC parameters, except for basophil granulocytes. Alinity hq WBC differential showed high level of agreement with manual differential results and exhibited a better agreement with manual basophil results than CELL-DYN Sapphire. The sensitivity of the Alinity hq Blast flag was 57.6%, equal to the 57.6% sensitivity of the CELL-DYN Sapphire's Blast Alert. When considering samples with ≥5% blasts, the sensitivity of the Alinity hq Blast flag was 70.0%. Analytical performance of Alinity hq was shown to be consistent with state-of-the-art (SOTA) performance characteristics. Conclusions Alinity hq CBC measurands demonstrated good overall agreement with results obtained with CELL-DYN Sapphire, as well as manual WBC differential. The analytical and clinical performance characteristics of Alinity hq make it well suited for clinical laboratories.


Subject(s)
Blood Cell Count/instrumentation , Hematology/instrumentation , Automation, Laboratory/instrumentation , Blood Cell Count/methods , Clinical Laboratory Services , Hematology/methods , Humans , Laboratories , Leukocyte Count , Leukocytes , Netherlands , Reproducibility of Results
2.
Am J Clin Pathol ; 136(4): 631-6, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21917687

ABSTRACT

The aim of our study was to assess the fetal RBC count in maternal blood during uncomplicated pregnancies from 26 weeks onward. We used a flow cytometric method specifically designed for use in a routine hematology analyzer. Pregnant women were recruited through midwives. The participating laboratories used the FMH QuikQuant method (Trillium Diagnostics, Brewer, ME) in a CELL-DYN Sapphire hematology analyzer (Abbott Diagnostics, Santa Clara, CA). The method is based on a monoclonal antibody to hemoglobin F. Flow cytometric data were analyzed by 2 independent observers. The 95th percentile reference range was estimated according to Clinical and Laboratory Standards Institute guidelines. A total of 236 samples were statistically analyzed. Gestational ages ranged from 21.6 to 41 weeks (mean, 32.0 weeks), and the fetal RBC count in maternal blood ranged from 0.00% to 0.50% (median, 0.025%). The fetal RBC count in maternal blood shows no correlation with gestational age. The established reference range during normal pregnancy is less than 0.125%.


Subject(s)
Erythrocyte Count/methods , Erythrocytes/cytology , Flow Cytometry/methods , Pregnancy/blood , Cell Separation , Female , Fetomaternal Transfusion/blood , Fetus , Humans , Reference Values