Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr Sci ; 55(10): 979-988, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28985272

ABSTRACT

The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene-divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.


Subject(s)
Chromatography, High Pressure Liquid/methods , Enalapril/analysis , Drug Contamination , Drug Stability , Enalapril/chemistry , Limit of Detection , Linear Models , Reproducibility of Results , Tablets
2.
J Chromatogr Sci ; 54(9): 1514-1521, 2016 Oct 17.
Article in English | MEDLINE | ID: mdl-27270417

ABSTRACT

A new rapid stability-indicating reversed-phase UPLC method was developed and validated for the determination of Bromfenac sodium and its impurities in Bromfenac ophthalmic solution. During literature search, only a few publications were found about Bromfenac sodium. There is no official monograph in the pharmacopoeias about Bromfenac sodium. Chromatographic separation has been achieved on a polar-embedded Waters Acquity BEH Shield RP18 (100 mm × 2.1 mm, 1.7 µm) column under gradient elution by using a binary mixture of potassium dihydrogen phosphate (0.01 M, pH 3.3) and acetonitrile (ACN) at a flow rate of 0.5 mL/min. Chromatogram was monitored at 265 nm using a photodiode array detector (PDA). The drug and its related impurities are eluted within 13 min. Resolution of Bromfenac sodium and all eight potential impurities have been achieved greater than 4.0 for all pairs of compounds. To prove the stability-indicating power of the method, the drug was subjected to hydrolytic (acid, alkaline and water), oxidative, photolytic and thermal stress, and the major degradation products were identified based on LC-MS analysis. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, precision, accuracy and robustness.

3.
J Chromatogr Sci ; 54(5): 765-75, 2016.
Article in English | MEDLINE | ID: mdl-26860397

ABSTRACT

A novel, simple, sensitive, selective and reproducible stability-indicating high performance liquid chromatographic method was developed for the quantitative determination of degradation products and process-related impurities of ketoprofen (KET) and omeprazole (OMZ) in combined oral solid dosage form. Chromatographic separation was achieved on a Phenomenex Luna C18 (2) column (150 × 4.6 mm, 5 µm) under gradient elution by using a binary mixture of potassium dihydrogen phosphate buffer and acetonitrile at a flow rate of 0.8 mL/min. Chromatogram was monitored at 233 nm for KET impurities and at 305 nm for OMZ impurities using a dual wavelength UV detector. Resolution for KET and OMZ and 14 impurities was found to be >1.5 for any pair of components. Typical retention behaviors of impurities at various pH values were depicted graphically. To prove the stability-indicating power of the method, the drug product was subjected to hydrolytic, oxidative, photolytic, humidity and thermal stress conditions as per ICH. The developed method was validated according to the current ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness and robustness.


Subject(s)
Capsules/chemistry , Chromatography, High Pressure Liquid/methods , Chromatography, Reverse-Phase/methods , Ketoprofen/analysis , Omeprazole/analysis , Drug Combinations , Reference Standards
4.
J Chromatogr Sci ; 53(5): 662-75, 2015.
Article in English | MEDLINE | ID: mdl-25186277

ABSTRACT

A simple, sensitive, selective and reproducible stability-indicating ultra-performance liquid chromatographic method was developed for the quantitative determination of degradation products and process-related impurities of Ritonavir in a pharmaceutical dosage form. Chromatographic separation was achieved on a polar embedded Waters Acquity BEH Shield RP18 (100 × 2.1 mm, 1.7 µm) column thermostated at 50°C under gradient elution by using a binary mixture of potassium dihydrogen phosphate (0.01 M, pH 3.5) and acetonitrile at a flow rate of 0.5 mL/min. Chromatogram was monitored at 240 nm using a photodiode array detector. The drug and its related impurities are eluted within 20 min. To prove the stability-indicating power of the method, the drug was subjected to hydrolytic (acid, alkaline and water), oxidative, photolytic and thermal stress conditions. The unknown degradants were identified by the LC-MS-MS method, which revealed protonated molecular ion peaks [M + H](+) at m/z 551.40 for hydrolytic degradants, and m/z 737.60 and m/z 753.40 for photolytic degradants. A plausible mechanism for the formation of degradation and process impurities was proposed. The performance of the method was validated according to the International Conference on Harmonization guidelines.

SELECTION OF CITATIONS
SEARCH DETAIL
...