Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Dent Mater ; 39(4): 402-409, 2023 04.
Article in English | MEDLINE | ID: mdl-36894413

ABSTRACT

OBJECTIVES: The purpose of this study was to characterize physicochemical properties and investigate anti-bacterial adhesion effect of dental resins containing fluorinated monomers. METHOD: Fluorinated dimethacrylate FDMA was mixed with commonly used reactive diluent triethylene- glycol dimethacrylate (TEGDMA) and fluorinated diluent 1 H,1 H-heptafluorobutyl methacrylate (FBMA) separately at a mass ratio of 60 wt./40 wt. to prepare fluorinated resin systems. Double bond conversion (DC), flexural strength (FS) and modulus (FM), water sorption (WS) and solubility (SL), contact angle and surface free energy, surface element concentration, and anti-adhesion effect against Streptococcus mutans (S. mutans) were investigated according to standard or referenced methods. 2,2-bis[4-(2-hydroxy-3-methacryloy-loxypropyl)-phenyl]propane (Bis-GMA)/TEGDMA (60/40, wt./wt.) was used as control. RESULTS: Both fluorinated resin systems had higher DC than Bis-GMA based resin (p < 0.05); compared with Bis-GMA based resin (FS, FDMA/TEGDMA resin system had higher FS (p < 0.05) and comparable FM (p > 0.05), while FDMA/FBMA resins system had lower FS and FM (p < 0.05). Both fluorinated resin systems had lower WS and SL than Bis-GMA based resin (p < 0.05), and FDMA/TEGDMA resin system had the lowest WS (p < 0.05) in all experimental resin systems. Only FDMA/FBMA resin system showed lower surface free energy than Bis-GMA based resin (p < 0.05). When the surface was smooth, FDMA/FBMA resin system had lower amount of adherent S. mutans than Bis-GMA based resin (p < 0.05), while after the surface became roughness, FDMA/FBMA resin system had comparable amount of adherent S. mutans as Bis-GMA based resin (p > 0.05). SIGNIFICANCE: Resin system prepared exclusively with fluorinated methacrylate monomers reduced the S. mutans adhesion due to their increased hydrophobicity and decreased surface energy., while flexural properties of it should be improved.


Subject(s)
Resins, Synthetic , Streptococcus mutans , Bisphenol A-Glycidyl Methacrylate/chemistry , Resins, Synthetic/chemistry , Polymethacrylic Acids/chemistry , Polyethylene Glycols/chemistry , Methacrylates/chemistry , Materials Testing , Composite Resins/pharmacology
2.
Eur J Oral Sci ; 127(6): 564-569, 2019 12.
Article in English | MEDLINE | ID: mdl-31830349

ABSTRACT

The aim of this study was to evaluate the dentine bond strength of a novel fast-setting calcium silicate cement (Protooth) versus a calcium hydroxide-based cement (Dycal), a calcium silicate cement (ProRoot MTA), and a glass ionomer cement (Ketac-Molar). Mid-root dentine slices of 1 mm thickness were obtained from human maxillary incisors. After enlarging the lumen of the canal to 1.3 mm, the cavities were randomly filled with test materials. Samples were immersed in physiological-like solution. The push-out bond strength was tested on days 1, 28, and 180 (n = 12). Failure types of bonding were determined using a stereomicroscope. We analysed the data using linear regression. Dycal and day 1 were considered as reference for cement type and assessment time, respectively. Protooth, Ketac-Molar, and ProRoot MTA demonstrated higher push-out bond strength than Dycal. The push-out bond strength in the Protooth group increased on day 28 and 180. The bond strength of Ketac-Molar was significantly reduced on day 28. Dycal showed a significant decrease in bond strength on day 180 compared with that on day 1 and 28. Mixed failure was the dominant failure type. Protooth bonding to dentine was increased with time, in contrast to that of ProRoot MTA, Dycal, and Ketac-Molar, as a function of time.


Subject(s)
Calcium Compounds , Dental Bonding , Dentin , Fluorides , Silicate Cement , Silicates , Aluminum Compounds , Calcium , Glass Ionomer Cements , Humans , In Vitro Techniques , Materials Testing , Oxides , Random Allocation
3.
Eur J Oral Sci ; 127(1): 81-88, 2019 02.
Article in English | MEDLINE | ID: mdl-30412313

ABSTRACT

The lifespan of a resin-based restoration is limited, with the main reason for failure being secondary caries. Biofilm formation at the tooth-material interface is a necessary etiological agent for caries development. Dental materials with antimicrobial properties may reduce formation of biofilm and thus increase the longevity of restorations. This study aimed to investigate the effect of methacrylated chitosan (CH-MA), incorporated into the polymeric network of an experimental dental composite and adhesive, on biofilm growth of Streptococcus mutans and to assess the mechanical properties of the modified materials. The methacrylation of low-molecular-weight chitosan was achieved and biofilm studies confirmed the antibacterial effect of the modified polymer in solution. Methacrylated chitosan was incorporated into an experimental composite and adhesive, and the modified materials reduced the formation of S. mutans biofilm. The incorporation of CH-MA did not alter the bond strength of the adhesives. However, the amount of CH-MA in composite that is required to elicit an antibacterial response challenges the mechanical properties of the material. The hardness and flexural strength of the composite decreased with increasing amounts of CH-MA. However, flexural strength values still met the requirement in the ISO standard.


Subject(s)
Biofilms/drug effects , Chitosan , Composite Resins , Dentin-Bonding Agents , Streptococcus mutans , Chitosan/chemistry , Chitosan/pharmacology , Composite Resins/pharmacology , Dentin-Bonding Agents/pharmacology , Humans , Materials Testing , Methacrylates/chemistry
4.
Dent Mater ; 34(7): 1003-1013, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29661580

ABSTRACT

OBJECTIVE: Synthesize a new BPA-free monomer for use in methacrylate-based materials and evaluate critical properties of resin and composite materials based on the monomer. METHODS: Bis-EFMA was synthesized through reaction between 9,9-bis[4-(2-hydroxyethoxy)-phenyl]fluorene and 2-(methacryloyloxy)ethyl isocyanate. Experimental Bis-EFMA-based resin (Bis-EFMA/TEGDMA=50/50, wt./wt.) and composite were prepared. Critical properties were investigated according to standard or referenced methods Bis-GMA/TEGDMA (50/50, wt./wt.) resin system, Bis-GMA-based composite and 3M ESPE Filtek™ Z250 were used as controls. RESULTS: FT-IR and 1H NMR spectra confirmed the structure of Bis-EFMA monomer. Cured resin materials: Bis-EFMA-based and Bis-GMA-based resins had nearly the same degree of conversion (p>0.05); Bis-EFMA-based resin had significantly lower shrinkage, water sorption and solubility, and cytotoxicity than Bis-GMA-based resin (p<0.05); flexural properties of Bis-EFMA-based resin were all higher than those of Bis-GMA-based resin (p<0.05). Cured composite materials: There was no significant difference in conversion (p>0.05); Bis-EFMA-based composite had significantly lower shrinkage and solubility (p<0.05); water sorption of Bis-EFMA-based composite and Z250 were similar (p>0.05), but lower compared to Bis-GMA-based composite (p<0.05); Bis-EFMA-based composite had the deepest curing depth (p<0.05); Before water immersion, there was no significant difference in flexural strength between Bis-EFMA-based composite and each control composite (p>0.05), while FS became lower than that of Z250 (p<0.05), but higher than that of Bis-GMA-based composite (p<0.05) after water immersion; Flexural modulus of Bis-EFMA-based composite and Z250 were nearly the same (p>0.05), higher than that of Bis-GMA-based composite (p<0.05); Bis-EFMA-based composite showed less cytotoxicity than Bis-GMA-based composite and Z250 (p<0.05). SIGNIFICANCE: Bis-EFMA has potential as a substitute for Bis-GMA to prepare Bis-GMA-free dental composites.


Subject(s)
Composite Resins/chemical synthesis , Fluorenes/chemistry , Isocyanates/chemistry , Magnetic Resonance Spectroscopy , Materials Testing , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Spectroscopy, Fourier Transform Infrared
5.
Acta Biomater Odontol Scand ; 3(1): 47-52, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28642931

ABSTRACT

Purpose: Some patients experience adverse reactions to poly(methyl methacrylate)-based (PMMA) dentures. Polyamide (PA) as an alternative to PMMA has, however, not been well documented with regard to water sorption and water solubility. The aim of this in vitro study was to measure water sorption and water solubility of two PA materials compared with PMMA, and to evaluate the major components released from the PA materials and the effect on hardness of the materials. Methods: Ten discs (40.0 mm diameter, 2.0 mm thick) of each material (PA: Valplast and Breflex; PMMA: SR Ivocap HIP) were prepared according to manufacturers' recommendations. The specimens were tested for water sorption and water solubility, according to a modification of ISO 20795-1:2008. Released substances were analysed by gas chromatography/mass spectrometry (GC/MS). Results: There were statistically significant differences among the materials regarding water sorption, water solubility and time to water saturation. Breflex had the highest water sorption (30.4 µg/mm3), followed by PMMA-material (25.8 µg/mm3) and Valplast (13.6 µg/mm3). Both PA materials had statistically significant lower water solubility than the PMMA. Both PA had a net increase in weight. Analysis by GC/MS identified release of the compound 12-aminododecanolactam from the material Valplast. No release was found from the Breflex material. Conclusions: The PA denture materials show differences in water sorption and solubility, but within the limits of the standard requirements. The PA showed a net increase in weight after long-term water sorption. The clinical implications of the findings are not elucidated.

6.
Int J Microbiol ; 2016: 9159761, 2016.
Article in English | MEDLINE | ID: mdl-27635144

ABSTRACT

Aim. The aim of this study was to investigate the antibacterial and antibiofilm properties of low viscosity chitosan on S. epidermidis growth and biofilm formation. Methods and Results. The antibacterial and antibiofilm properties were investigated, during both planktonic growth and biofilm formation. This was performed using different concentrations in media and by coating on polystyrene surfaces. In addition, the bactericidal effect was investigated using a modified direct contact test. The results showed that low viscosity chitosan in media had both a bacteriostatic and bactericidal effect on planktonic growth and biofilm formation of S. epidermidis in a concentration dependent manner. Polystyrene discs coated with chitosan reduced both early biofilm formation (6 h) and late biofilm formation (18 h), as confirmed by scanning electron microscopy. The modified direct contact test showed a bactericidal effect. Conclusion. This study demonstrated that low viscosity chitosan has a bacteriostatic and bactericidal activity against S. epidermidis and that the activity is dependent on the amount of chitosan added. In addition, low viscosity chitosan reduced biofilm formation both when added to media and when coated on polystyrene surfaces. Significance and Impact of Study. Low viscosity chitosan could be a contribution to new treatment approaches of biofilm-related infections of S. epidermidis.

7.
Eur J Oral Sci ; 121(5): 488-96, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24028598

ABSTRACT

Root canal sealing materials may have toxic potential in vitro depending on the cell line, cytotoxicity assay, material chemistry, and degree of polymer curing. The aims of the present study were to detect leaching components from epoxy- or methacrylate-based root canal sealers and to investigate the degree of cytotoxicity after exposure to extracts from these materials. Qualitative determination of substances released from the materials was performed by gas- and liquid chromatography/mass spectrometry. Submandibular salivary gland acinar cell death (apoptosis/necrosis) was determined using a fluorescence staining/microscopy technique. The major leachable monomer from the epoxy-based material was bisphenol-A diglycidyl ether (BADGE), whereas leachables from the methacrylate-based materials were mainly triethylene glycol dimethacrylate (TEGDMA), urethane dimethacrylate (UDMA), hydroxyethyl methacrylate (HEMA), and polyethyleneglycol dimethacrylate (PEGDMA). Exposure to diluted extracts of cured methacrylate-based materials caused a postexposure time-dependent increase in cell death. This effect was not demonstrated as a result of exposure to undiluted extract of cured epoxy-based material. Extracts of all fresh materials induced apoptosis significantly, but at lower dilutions of the epoxy- than the methacrylate-based materials. The degree of leaching, determined from the relative chromatogram peak heights of eluates from the methacrylate-based sealer materials, corresponded with the degree of cell death induced by extracts of these materials.


Subject(s)
Acinar Cells/cytology , Cell Death/drug effects , Cytotoxins/chemistry , Epoxy Resins/toxicity , Polymethacrylic Acids/toxicity , Root Canal Filling Materials/toxicity , Salivary Glands/cytology , Animals , Cell Culture Techniques , Chromatography, Liquid , Epoxy Resins/chemistry , Gas Chromatography-Mass Spectrometry , Polymethacrylic Acids/chemistry , Rats , Root Canal Filling Materials/chemistry
8.
Dent Mater ; 29(8): 824-34, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23764027

ABSTRACT

OBJECTIVES: The latest LED dental curing devices claim sufficient curing of restorative materials with short curing times. This study evaluates mechanical and chemical properties as a function of curing time of two commercial composite filling materials cured with three different LED lamps. METHODS: The composites were Filtek Z250 (3M ESPE) and Tetric EvoCeram (Ivoclar Vivadent) and the LED curing devices were bluephase 16i (Ivoclar Vivadent), L.E.Demetron II (Kerr) and Mini L.E.D. (Satelec). Control samples were cured with a QTH-lamp (VCL 400, Kerr). The wear resistance after simulated tooth brushing, degree of conversion, curing depth, and amounts of residual monomers were measured after different curing times. RESULTS: The results of this study show that short curing time with high-intensity LEDs may influence the bulk properties of the materials, resulting in lower curing depth and increased residual monomer content. The measured surface properties of the materials, degree of conversion and wear resistance, were not affected by short curing times to the same extent. SIGNIFICANCE: This study demonstrates that reduced exposure time with high intensity LEDs can result in composite restorations with inferior curing depth and increased leaching of monomers. Dentists are recommended to use sufficient curing times even with high intensity LEDs to ensure adequate curing and minimize the risk of monomer leaching.


Subject(s)
Composite Resins/radiation effects , Curing Lights, Dental/classification , Bisphenol A-Glycidyl Methacrylate/chemistry , Chromatography, High Pressure Liquid/methods , Composite Resins/chemistry , Equipment Design , Humans , Light-Curing of Dental Adhesives/instrumentation , Light-Curing of Dental Adhesives/methods , Materials Testing , Mechanical Phenomena , Methacrylates/chemistry , Microscopy, Electron, Scanning , Polymerization , Polyurethanes/chemistry , Spectrophotometry, Ultraviolet/methods , Spectroscopy, Fourier Transform Infrared/methods , Surface Properties , Tandem Mass Spectrometry/methods , Time Factors , Toothbrushing/instrumentation
9.
Eur J Oral Sci ; 118(1): 100-2, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20156272

ABSTRACT

Previous studies have shown that residual monomers, initiators, and additives are eluted from methacrylate-based dental composite materials. Recently, a composite material (Filtek Silorane), based on a new resin chemistry, was introduced. The purpose of this study was to investigate substances eluted from Filtek Silorane in water and ethanol. Polymerized specimen discs of the material were immersed in either distilled water or 75 vol% ethanol at 37 degrees C, and the solutions were analyzed using liquid chromatography-mass spectrometry after 1, 4, 24, and 72 h eluting time. No substances were found to leach from Filtek Silorane in water, whereas silorane monomers and an initiator component were eluted from the material into the ethanol solution.


Subject(s)
Composite Resins/chemistry , Ethylene Oxide/analysis , Light-Curing of Dental Adhesives , Materials Testing , Siloxanes/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...