Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Endosc Ultrasound ; 5(2): 78-84, 2016.
Article in English | MEDLINE | ID: mdl-27080605

ABSTRACT

BACKGROUND AND OBJECTIVES: Recent reports have indicated that the time of day may impact the detection rate of abnormal cytology on gynecologic cytology samples. The aim of this study was to determine if procedure time or queue position affected the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosing solid pancreatic malignancies. PATIENTS AND METHODS: We conducted a retrospective study evaluating patients with solid pancreatic lesions in whom EUS-FNA was performed. Three timing variables were evaluated as surrogate markers for endoscopist fatigue: Procedure start times, morning versus afternoon procedures, and endoscopy queue position. Statistical analyses were performed to determine whether the timing variables predicted performance characteristics of EUS-FNA. RESULTS: We identified 609 patients (mean age: 65.8 years, 52.1% males) with solid pancreatic lesions who underwent EUS-FNA. The sensitivity of EUS-FNA was 100% for procedures that started at 7 AM while cases that started at 4 PM had a sensitivity of 81%. Using start time on a continuous scale, each elapsed hour was associated with a 1.9% decrease in EUS-FNA sensitivity (P = 0.003). Similarly, a 10% reduction in EUS-FNA sensitivity was detected between morning and afternoon procedures (92% vs. 82% respectively, P = 0.0006). A linear regression comparing the procedure start time and diagnostic accuracy revealed a decrease of approximately 1.7% in procedure accuracy for every hour later a procedure was started. A 16% reduction in EUS-FNA accuracy was detected between morning and afternoon procedures (100% vs. 84% respectively, P = 0.0009). When the queue position was assessed, a 2.4% reduction in accuracy was noted for each increase in the queue position (P = 0.013). CONCLUSION: Sensitivity and diagnostic accuracy of EUS-FNA for solid pancreatic lesions decline with progressively later EUS starting times and increasing numbers of procedures before a given EUS, potentially from endoscopist fatigue and cytotechnologist fatigue.

2.
Diagn Ther Endosc ; 2015: 793516, 2015.
Article in English | MEDLINE | ID: mdl-26681910

ABSTRACT

Background and Aim. Spiral enteroscopy (SE) is a new small bowel endoscopic technique. Our aim is to review the diagnostic and therapeutic yield, safety of SE, and the predictive role of prior capsule endoscopy (CE) at an academic center. Methods. A retrospective review of patients undergoing SE after prior CE between 2008 and 2013 was performed. Capsule location index (CLI) was defined as the fraction of total small bowel transit time when the lesion was seen on CE. Results. A total of 174 SEs were performed: antegrade (147) and retrograde (27). Abnormalities on SE were detected in 65% patients. The procedure was safe in patients with surgically altered bowel anatomy (n = 12). The diagnostic yield of antegrade SE decreased with increasing CLI range. The diagnostic yield of retrograde SE decreased on decreasing CLI range. A CLI cutoff of 0.6 was derived that determined the initial route of SE. Vascular ectasias seen on CE were detected in 83% cases on SE; p < 0.01. Conclusions. SE is safe with a high diagnostic and therapeutic yield. CLI is predictive of the success of SE and determines the best route of SE. The type of small bowel pathology targeted by SE may affect its utility and yield.

6.
J Interv Gastroenterol ; 2(4): 172-176, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23687604

ABSTRACT

BACKGROUND AND AIMS: The diagnosis of intra-abdominal lymphadenopathy of is difficult, especially when no primary lesion has been identified. We aimed to evaluate the diagnostic yield of EUS-FNA cytology in patients with enlarged intra-abdominal lymph nodes of unknown etiology. PATIENT AND METHODS: 147 patients with abdominal lymphadenopathy on imaging in whom EUS-FNA was performed with a 22-gauge needle. Performance characteristics of EUS-FNA including the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were compared between the 2 groups. RESULTS: AThe location of the enlarged lymph nodes was the celiac axis (8.2%), peri-gastric (34%), peri-pancreatic (25.2%), peri-portal (27.9%), and other intra-abdominal locations (4.8%). The median number of EUS-FNA passes was 5. The final diagnosis were lymphoma in (n=27), metastatic adenocarcinoma (n=44) patients, other miscellaneous malignancies (n=22) and benign disease (n=54). The sensitivity, specificity, and accuracy of EUS-FNA were 89.7, 98.3, and 93.5% respectively. A false positive FNA result was present in only 1 case (0.7%); false negative FNA results were present in eight cases (5.8%). Lymph node morphologic features of roundness, echogenicity, and homogeneity on EUS were not a predictor of lymph node malignancy. CONCLUSION: In a retrospective cohort trial, EUS-FNA was found to be highly accurate and safe in diagnosing patients with intra-abdominal lymphadenopathy of unknown etiology.

7.
Dig Dis Sci ; 56(11): 3370-5, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21688127

ABSTRACT

BACKGROUND: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. AIM: The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. METHODS: Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. RESULTS: We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size <1, 1-2, 2-3, 3-4, and >4 cm was 40, 75.9, 86.9, 93.2, and 91.6%, respectively; EUS-FNA sensitivity strongly correlate with tumor size (p < 0.001). Similarly, the accuracy of EUS-FNA increased as lesion size increased, ranging from 47% for tumors less than 1 cm to 88% for tumors greater than 4 cm (p < 0.05). Location of tumor and number of needle passes did not significantly influence EUS-FNA performance characteristics. CONCLUSIONS: The sensitivity and diagnostic accuracy of EUS-FNA for solid pancreatic lesions is strongly correlated with tumor size. Sensitivity and accuracy decrease significantly for tumors that are smaller than 1 cm.


Subject(s)
Pancreas/pathology , Pancreatic Neoplasms/pathology , Aged , Biopsy, Fine-Needle , Endoscopy, Digestive System , Female , Humans , Male , Middle Aged , Retrospective Studies , Ultrasonography, Interventional
8.
Biotechnol Healthc ; 3(1): 55-8, 2006 Feb.
Article in English | MEDLINE | ID: mdl-23424337

ABSTRACT

Biotechnology breakthroughs are coming from developing countries like China and India that are seeking a competitive edge in the world market. But will private investors step up to make it happen? Here are some reasons why they should.

SELECTION OF CITATIONS
SEARCH DETAIL
...