Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 94(3): 1575-1584, 2022 01 25.
Article in English | MEDLINE | ID: mdl-35015512

ABSTRACT

Tissue cross-linking represents an important and often used technique to enhance the mechanical properties of biomaterials. For the first time, we investigated biochemical and structural properties of genipin (GE) cross-linked equine pericardium (EP) using optical imaging techniques in tandem with quantitative atomic force microscopy (AFM). EP was cross-linked with GE at 37 °C, and its biochemical and biomechanical properties were observed at various time points up to 24 h. GE cross-linked EP was monitored by the normalized ratio between its second-harmonic generation (SHG) and two-photon autofluorescence emissions and remained unchanged for untreated EP; however, a decreasing ratio due to depleted SHG and elevated autofluorescence and a fluorescence band at 625 nm were found for GE cross-linked EP. The mean autofluorescence lifetime of GE cross-linked EP also decreased. The biochemical signature of GE cross-linker and shift in collagen bands were detected and quantified using shifted excitation Raman difference spectroscopy as an innovative approach for tackling artifacts with high fluorescence backgrounds. AFM images indicated a higher and increasing Young's modulus correlated with cross-linking, as well as collagen structural changes in GE cross-linked EP, qualitatively explaining the observed decrease in the second-harmonic signal. In conclusion, we obtained detailed information about the biochemical, structural, and biomechanical effects of GE cross-linked EP using a unique combination of optical and force microscopy techniques in a nondestructive and label-free manner.


Subject(s)
Collagen , Iridoids , Animals , Collagen/chemistry , Elastic Modulus , Horses , Iridoids/analysis , Pericardium
2.
Analyst ; 146(22): 6760-6767, 2021 Nov 08.
Article in English | MEDLINE | ID: mdl-34704561

ABSTRACT

Shifted excitation Raman difference spectroscopy (SERDS) can be used as an instrumental baseline correction technique to retrieve Raman bands in highly fluorescent samples. Genipin (GE) cross-linked equine pericardium (EP) was used as a model system since a blue pigment is formed upon cross-linking, which results in a strong fluorescent background in the Raman spectra. EP was cross-linked with 0.25% GE solution for 0.5 h, 2 h, 4 h, 6 h, 12 h, and 24 h, and compared with corresponding untreated EP. Raman spectra were collected with three different excitation wavelengths. For the assessment of the SERDS technique, the preprocessed SERDS spectra of two excitation wavelengths (784 nm-786 nm) were compared with the mathematical baseline-corrected Raman spectra at 785 nm excitation using extended multiplicative signal correction, rubberband, the sensitive nonlinear iterative peak and polynomial fitting algorithms. Whereas each baseline correction gave poor quality spectra beyond 6 h GE crosslinking with wave-like artefacts, the SERDS technique resulted in difference spectra, that gave superior reconstructed spectra with clear collagen and resonance enhanced GE pigment bands with lower standard deviation. Key for this progress was an advanced difference optimization approach that is described here. Furthermore, the results of the SERDS technique were independent of the intensity calibration because the system transfer response was compensated by calculating the difference spectrum. We conclude that this SERDS strategy can be transferred to Raman studies on biological and non-biological samples with a strong fluorescence background at 785 nm and also shorter excitation wavelengths which benefit from more intense scattering intensities and higher quantum efficiencies of CCD detectors.


Subject(s)
Artifacts , Spectrum Analysis, Raman , Algorithms , Animals , Calibration , Coloring Agents , Horses
3.
Sensors (Basel) ; 20(23)2020 Nov 24.
Article in English | MEDLINE | ID: mdl-33255459

ABSTRACT

Wide field Raman imaging using the integral field spectroscopy approach was used as a fast, one shot imaging method for the simultaneous collection of all spectra composing a Raman image. For the suppression of autofluorescence and background signals such as room light, shifted excitation Raman difference spectroscopy (SERDS) was applied to remove background artifacts in Raman spectra. To reduce acquisition times in wide field SERDS imaging, we adapted the nod and shuffle technique from astrophysics and implemented it into a wide field SERDS imaging setup. In our adapted version, the nod corresponds to the change in excitation wavelength, whereas the shuffle corresponds to the shifting of charges up and down on a Charge-Coupled Device (CCD) chip synchronous to the change in excitation wavelength. We coupled this improved wide field SERDS imaging setup to diode lasers with 784.4/785.5 and 457.7/458.9 nm excitation and applied it to samples such as paracetamol and aspirin tablets, polystyrene and polymethyl methacrylate beads, as well as pork meat using multiple accumulations with acquisition times in the range of 50 to 200 ms. The results tackle two main challenges of SERDS imaging: gradual photobleaching changes the autofluorescence background, and multiple readouts of CCD detector prolong the acquisition time.

4.
Molecules ; 25(17)2020 Aug 25.
Article in English | MEDLINE | ID: mdl-32854230

ABSTRACT

Biomaterials used in tissue engineering and regenerative medicine applications benefit from longitudinal monitoring in a non-destructive manner. Label-free imaging based on fluorescence lifetime imaging (FLIm) and Raman spectroscopy were used to monitor the degree of genipin (GE) cross-linking of antigen-removed bovine pericardium (ARBP) at three incubation time points (0.5, 1.0, and 2.5 h). Fluorescence lifetime decreased and the emission spectrum redshifted compared to that of uncross-linked ARBP. The Raman signature of GE-ARBP was resonance-enhanced due to the GE cross-linker that generated new Raman bands at 1165, 1326, 1350, 1380, 1402, 1470, 1506, 1535, 1574, 1630, 1728, and 1741 cm-1. These were validated through density functional theory calculations as cross-linker-specific bands. A multivariate multiple regression model was developed to enhance the biochemical specificity of FLIm parameters fluorescence intensity ratio (R2 = 0.92) and lifetime (R2 = 0.94)) with Raman spectral results. FLIm and Raman spectroscopy detected biochemical changes occurring in the collagenous tissue during the cross-linking process that were characterized by the formation of a blue pigment which affected the tissue fluorescence and scattering properties. In conclusion, FLIm parameters and Raman spectroscopy were used to monitor the degree of cross-linking non-destructively.


Subject(s)
Cross-Linking Reagents/chemistry , Extracellular Matrix/chemistry , Iridoids/chemistry , Pericardium/chemistry , Animals , Cattle , Optical Imaging , Pericardium/diagnostic imaging , Spectrum Analysis, Raman
5.
Sensors (Basel) ; 17(8)2017 Jul 27.
Article in English | MEDLINE | ID: mdl-28749450

ABSTRACT

Raman spectroscopy provides label-free biochemical information from tissue samples without complicated sample preparation. The clinical capability of Raman spectroscopy has been demonstrated in a wide range of in vitro and in vivo applications. However, a challenge for in vivo applications is the simultaneous excitation of auto-fluorescence in the majority of tissues of interest, such as liver, bladder, brain, and others. Raman bands are then superimposed on a fluorescence background, which can be several orders of magnitude larger than the Raman signal. To eliminate the disturbing fluorescence background, several approaches are available. Among instrumentational methods shifted excitation Raman difference spectroscopy (SERDS) has been widely applied and studied. Similarly, computational techniques, for instance extended multiplicative scatter correction (EMSC), have also been employed to remove undesired background contributions. Here, we present a theoretical and experimental evaluation and comparison of fluorescence background removal approaches for Raman spectra based on SERDS and EMSC.


Subject(s)
Spectrum Analysis, Raman , Computers , Spectrometry, Fluorescence
SELECTION OF CITATIONS
SEARCH DETAIL
...