Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Foot Ankle Surg ; 28(3): 324-330, 2022 Apr.
Article in English | MEDLINE | ID: mdl-33858758

ABSTRACT

BACKGROUND: To measure the motion of polyethylene insert and implant components of mobile-bearing total ankle replacement (TAR) by cone-beam CT scanning. METHODS: 10 TAR patients with high amount of clinical motion after the CCI implant (Ceramic Coated Implant; Wright Medical Technology, Arlington, TN, USA) with average age at operation 64,3 years (range 47-84) and average clinical total range of motion 42 degrees (range 35-55) were included. RESULTS: The average total range of motion between the insert and the tibial component was 0.8mm (range 0-2) in the coronal plane, and 2.9mm (range 1-6) in the sagittal plane. There was wide variation in the axial rotation measurements between the components. CONCLUSION: We found measurable motion between the mobile-bearing insert and the tibial component in all planes. The relevance of this motion to the function and long-term survival of the TAR remains to be determined.


Subject(s)
Arthroplasty, Replacement, Ankle , Joint Prosthesis , Aged , Aged, 80 and over , Ankle Joint/diagnostic imaging , Ankle Joint/surgery , Cone-Beam Computed Tomography , Humans , Middle Aged , Prosthesis Design , Range of Motion, Articular
2.
Foot Ankle Int ; 42(11): 1431-1438, 2021 11.
Article in English | MEDLINE | ID: mdl-34142574

ABSTRACT

BACKGROUND: Peri-implant osteolysis is one of the major complications related to total ankle replacement. The aim of this study was to investigate the short- to midterm incidence of peri-implant osteolysis using computed tomography (CT) as imaging method for the Trabecular Metal Total Ankle (TMTA) implant representing a novel total ankle replacement (TAR) implant design regarding material and surgical technique. METHODS: In total, 104 consecutive patients who had a primary TMTA replacement between March 2013 and October 2017 were included in the study. The radiographic evaluation included weightbearing anteroposterior and lateral views at baseline and after 3, 6, and every 12 months postoperatively. A helical CT was undertaken preoperatively and of the 80 patients available to follow up at least 12 months postoperatively, with average time interval between the TAR operation and the latest CT of 39 (range, 12-85) months. RESULTS: Eight of 80 patients had altogether 11 osteolytic lesions around the components on CT images. Seven lesions were found in tibia, 3 in talus, and 1 in distal fibula. Four of the tibial lesions were situated in the medial malleolus and were not in contact with the prosthesis component. The sizes of the osteolytic lesions ranged between 7 and 20 mm, and the average volume of the lesions was 689 mm3. CONCLUSION: We conclude that the risk of peri-implant osteolysis with the TMTA implant is minimal in short to midterm. The anatomic configuration, unique material, and surgical technique may all contribute to the TMTA implant having a low rate of peri-implant osteolysis. LEVEL OF EVIDENCE: Level IV, case series.


Subject(s)
Arthroplasty, Replacement, Ankle , Joint Prosthesis , Osteolysis , Ankle Joint/diagnostic imaging , Ankle Joint/surgery , Arthroplasty, Replacement, Ankle/adverse effects , Follow-Up Studies , Humans , Osteolysis/diagnostic imaging , Osteolysis/etiology , Prosthesis Design , Retrospective Studies
3.
Foot Ankle Int ; 41(4): 411-418, 2020 04.
Article in English | MEDLINE | ID: mdl-31868017

ABSTRACT

BACKGROUND: Total ankle arthroplasty is an alternative for arthrodesis. The objective of this study was to investigate the safety of trabecular-metal ankle prosthetic system with transfibular approach and external frame and its association with changes in clinical and functional scores. METHODS: Between May 2013 and June 2017, a total of 104 consecutive patients underwent primary total ankle arthroplasty with a trabecular metal implant. The prospective clinical and radiographic data were collected. The mean follow-up time was 43.6 (14.6) months. RESULTS: Of 104 patients, 88 (89%) reported improved functioning and 65 (66%) were very satisfied with the surgery. Of the patients, 51 (50%) did not report any pain at the end of follow-up at all. The average Kofoed score was 37.6 (SD 17.4) points at baseline and 74.8 (SD 20.6) points at the end of follow-up. There were 37 additional procedures, and the complication rate was nearly 20%. CONCLUSION: Trabecular-metal total ankle prosthesis showed promising clinical results concerning pain and function. At 5-year follow-up, osteolysis and component loosening were rare. LEVEL OF EVIDENCE: Level IV, case series.


Subject(s)
Arthroplasty, Replacement, Ankle/methods , Joint Prosthesis , Prosthesis Design , Aged , Arthroplasty, Replacement, Ankle/instrumentation , Female , Fibula , Humans , Male , Middle Aged , Pain Measurement , Postoperative Complications , Prospective Studies , Surveys and Questionnaires , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...