1.
Sci Rep ; 14(1): 4098, 2024 02 19.
Article in English | MEDLINE | ID: mdl-38374368

ABSTRACT

We present a system for simultaneous recording of the electrocardiogram and the magnetocardiogram. The measurement system contained of printed carbon electrodes and SERF magnetometer. The use of this system confirms that the position of the end of the magnetic T wave extends further than the electric T wave, which is an important indicator for the diagnosis of cardiological patients and for drug arrhythmogenicity. We analyze this phenomenon in depth, and demonstrate, that it originates from the fundamental difference between electric and magnetic measurements. The measured value is always bipolar since the electric measurements require two electrodes. We demonstrate how the dual electric and magnetic measuring system adds a new information to the commonly used electrocardiographic diagnosis. The ECG should be interpreted as the spatial asymmetry of the electric cardiac potential, and not as the potential itself. The results seem to prove, that the relation between the magnetic and the electric imaging of neural activities may be broadly applied for the benefit of medical diagnosis in cardiology and many other fields, where the neural activity is measured. This is a pilot study which requires further confirmation at the clinical level.


Subject(s)
Magnetocardiography , Humans , Pilot Projects , Electrocardiography/methods , Heart , Arrhythmias, Cardiac , Electrodes
2.
J Magn Reson ; 343: 107288, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36209574

ABSTRACT

Interleaved Nuclear Quadrupole Resonance (NQR) detection was conducted on ammonium nitrate and potassium chlorate using two 87Rb magnetometers, where potassium chlorate is measured during the T1 limited recovery time of ammonium nitrate. The multi-pass magnetometers are rapidly matched to the NQR frequencies, 531 kHz and 423 kHz, with the use of a single tuning field. For ease of implementation, a double resonant tank circuit was used for excitation, but could be replaced by a broad-band transmitter. All work was done in an unshielded environment and compared to conventional coil detection. The two magnetometers were sensitive, base noise as low as 2 fT/Hz, and were shown to reduce ambient noise through signal subtraction. When an excitation pulse was introduced, however, residual ringing increased the noise floor; mitigation techniques are discussed. The two detection techniques resulted in comparable Signal-to-Noise Ratio (SNR). Interleaved detection using the atomic magnetometers took half the time of conventional detection and provided localization of the explosives.

3.
Nat Phys ; 17(12): 1396-1401, 2021.
Article in English | MEDLINE | ID: mdl-34966439

ABSTRACT

Ultralight bosons such as axion-like particles are viable candidates for dark matter. They can form stable, macroscopic field configurations in the form of topological defects that could concentrate the dark matter density into many distinct, compact spatial regions that are small compared with the Galaxy but much larger than the Earth. Here we report the results of the search for transient signals from the domain walls of axion-like particles by using the global network of optical magnetometers for exotic (GNOME) physics searches. We search the data, consisting of correlated measurements from optical atomic magnetometers located in laboratories all over the world, for patterns of signals propagating through the network consistent with domain walls. The analysis of these data from a continuous month-long operation of GNOME finds no statistically significant signals, thus placing experimental constraints on such dark matter scenarios.

4.
Sensors (Basel) ; 21(4)2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33572285

ABSTRACT

Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth (≥100 kHz) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about 600 fT/cm/Hz for a 2.3 cm baseline. The noise floor is flat up to 1 kHz and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about 1.37 µg of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of 100 µL.


Subject(s)
Magnetite Nanoparticles , Magnetic Fields , Magnetics , Software
5.
Sensors (Basel) ; 21(4)2021 Feb 05.
Article in English | MEDLINE | ID: mdl-33562551

ABSTRACT

This paper presents results from the integration of a compact quantum magnetometer system and an agile underwater glider for magnetic survey. A highly maneuverable underwater glider, ROUGHIE, was customized to carry an increased payload and reduce the vehicle's magnetic signature. A sensor suite composed of a vector and scalar magnetometer was mounted in an external boom at the rear of the vehicle. The combined system was deployed in a constrained pool environment to detect seeded magnetic targets and create a magnetic map of the test area. Presented is a systematic magnetic disturbance reduction process, test procedure for anomaly mapping, and results from constrained operation featuring underwater motion capture system for ground truth localization. Validation in the noisy and constrained pool environment creates a trajectory towards affordable littoral magnetic anomaly mapping infrastructure. Such a marine sensor technology will be capable of extended operation in challenging areas while providing high-resolution, timely magnetic data to operators for automated detection and classification of marine objects.