Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Mol Gen Mikrobiol Virusol ; (4): 32-7, 2013.
Article in Russian | MEDLINE | ID: mdl-24645276

ABSTRACT

The real time PCR assay targeting influenza A and B virus, 5 subtypes of influenza A virus (seasonal H1N1, pandemic H1N1 (2009), seasonal H3N2, pathogenic for human subtypes of avian influenza H5 and H7), respiratory syncytial virus, and adenovirus was developed. The analytical sensitivity of the developed assay was 1 x 10(3) genome equivalents per ml. The diagnostic sensitivity of the method was 1 x l0(3)-10(4) viral particles per ml. Experiments with human DNA/cDNA and viral cDNA showed a markedly high diagnostic specificity of the developed PCR assay. In the assay of the developed PCR test, 50 nasopharyngeal swab specimens were tested. The etiology was identified in 33 samples.


Subject(s)
Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza A Virus, H3N2 Subtype/isolation & purification , Influenza, Human/diagnosis , Real-Time Polymerase Chain Reaction/methods , Respiratory Tract Infections/diagnosis , Animals , Birds/virology , Humans , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H3N2 Subtype/genetics , Influenza A Virus, H5N1 Subtype/genetics , Influenza A Virus, H5N1 Subtype/isolation & purification , Influenza B virus/genetics , Influenza B virus/isolation & purification , Influenza in Birds/diagnosis , Influenza in Birds/virology , Influenza, Human/virology , Respiratory Tract Infections/genetics , Respiratory Tract Infections/virology
2.
Khirurgiia (Mosk) ; (6): 54-7, 2009.
Article in Russian | MEDLINE | ID: mdl-19668139

ABSTRACT

96 primary endoprosthetic hip replacements were performed in elderly patients with femoral neck fractures. The average age of the patients was 82,7 years. In cases of senile osteoporosis cement <> prosthesis was applied, when there were no signs of osteoporosis defined, non-cement <> construction was used. 53 (55,2%) patients were postoperatively followed-up during 1 to 7 years. Excellent result was achieved in 17 (32,1%) patients (>90 points on Harrison's scale), good result was registered in 21 (39,6%) patients (80-89 points), considered to be satisfactory (70-79 points) - in 15 (28,3%) patients.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femoral Neck Fractures/surgery , Hip Prosthesis , Aged , Aged, 80 and over , Female , Femoral Neck Fractures/diagnostic imaging , Follow-Up Studies , Humans , Male , Patient Satisfaction , Prosthesis Design , Radiography , Retrospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...