Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
Heliyon ; 10(2): e24307, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38304773

ABSTRACT

Purpose: Unicompartmental knee arthroplasty (UKA) is an established option for treating isolated unicompartmental knee osteoarthritis (OA), but controversies still exist about patient selection, indications, perioperative management and alignment goals. This survey was designed to understand the current trends of experienced arthroplasty knee surgeons performing UKA. Methods: An online questionnaire was created with SurveyMonkey® to assess global tendencies in the utilization of UKA. A link to the survey was shared with all ESSKA (European Society for Sports Traumatology, Knee Surgery and Arthroscopy) members. The questionnaire consisted of free and multiple-choice questions and was divided into four sections: demographic information, the surgical activity of the respondents, indications for surgery and postoperative alignment goals. Results: A total of 138 ESSKA members from 34 different countries completed the survey. A total of 81 % of the responders performed fewer than 50 UKAs per year; 53 % of UKAs represented less than 20 % of their knee replacements; 71 % used mainly or only fixed-bearing implants; 81 % performed UKA in a shorter time compared to TKA; and 61 % and 72 % were interested in custom-made UKA and robotics, respectively. Thirty-six percent considered a minimum postoperative alignment of 0° for medial UKA, and 32 % considered 10° as the maximum valgus deformity for lateral UKA. Fifty-five percent had no minimum age cut-off, 47 % had no BMI cut-off, and 57 % believed TKA was better than UKA in knees with concomitant high-grade patellofemoral OA. Approximately 50 % of the surgeons desired a coronal alignment that was the same as the predegeneration alignment. Conclusion: A high level of agreement was reached regarding the following: preference for fixed-bearing UKAs, lower surgical time for UKA compared to TKA, interest in custom-made and robotic UKAs, no age and weight cut-off, TKA preferred in the presence of patellofemoral OA, and a final alignment goal of the predegenerative state both for medial and lateral. There was no agreement regarding length of stay, rehabilitation protocol, preoperative varus and valgus cut-off values, and treatment in cases of absence of anterior cruciate ligament or previous osteotomy.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1230-1246, 2023 Apr.
Article in English | MEDLINE | ID: mdl-34432095

ABSTRACT

PURPOSE: The purpose of this systematic review and meta-analysis was to collect, synthesise and critically appraise findings of clinical studies that report outcomes of custom total knee arthroplasty (TKA). The hypothesis was that, compared to off-the-shelf (OTS) TKA, custom TKA would yield better surgical, clinical and radiographic outcomes. METHODS: This systematic review and meta-analysis was performed in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). On 8 February 2021, two authors independently searched and screened articles using MEDLINE®, Embase® and the Cochrane Library without restriction on date of publication. Findings from eligible articles were narratively synthesised and tabulated, and when ≥ 3 comparative studies reported the same outcome, results were pooled and summarised in forest plots. Quality assessments of the studies were done according to the guidelines of the Joanna Briggs Institute (JBI) Checklists. RESULTS: A total of 15 articles were eligible for data extraction, of which 9 were case-control studies reporting on 929 custom versus 998 OTS TKA, 5 were case series reporting on results of 587 custom TKA, and 1 was a cross-sectional study reporting on results of 44 custom versus 132 OTS TKA. Five studies that compared early revision rates found the overall effect in favour of OTS TKA (odds ratio (OR), 0.4; p = n.s.) but the result did not reach statistical significance. Four studies found no statistically significant difference in KSS knee (standardised mean difference (SMD), - 0.10; p = n.s.) and function (SMD, 0.03; p = n.s.), and five studies found no statistically significant difference in range of motion (SMD, 0.02; p = n.s.). One study that compared bone-implant fit between custom and three OTS tibial components found no overhang but revealed under-coverage of up to 18% in knees with custom tibial baseplates. CONCLUSION: Custom TKA demonstrated no significant benefits compared to OTS TKA in terms of pooled clinical outcomes, but had considerably higher early revision rates. The findings of the present systematic review and meta-analysis suggest the need for studies with better comparable groups and standardisation of reporting outcomes amongst studies, that could increase the quality of evidence and enable pooling of results in future meta-analyses. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Cross-Sectional Studies , Knee Joint/surgery , Tibia/surgery , Range of Motion, Articular , Osteoarthritis, Knee/surgery , Treatment Outcome
3.
World J Orthop ; 13(3): 307-328, 2022 Mar 18.
Article in English | MEDLINE | ID: mdl-35317256

ABSTRACT

BACKGROUND: Over the past decades, clinical pathways (CPs) for hip and knee arthroplasty have been strongly and continuously evolved based on scientific evidence and innovation. AIM: The present systematic review, including meta-analysis, aimed to compare the safety and efficacy of enhanced recovery pathways (ERP) with regular pathways for patients with hip and/or knee arthroplasty. METHODS: A literature search in healthcare databases (Embase, PubMed, Cochrane Library, CINAHL, and Web of Science) was conducted from inception up to June 2018. Relevant randomized controlled trials as well as observational studies comparing ERP, based on novel evidence, with regular or standard pathways, prescribing care as usual for hip and/or knee arthroplasty, were included. The effect of both CPs was assessed for (serious) adverse events [(S)AEs], readmission rate, length of hospital stay (LoS), clinician-derived clinical outcomes, patient reported outcome measures (PROMs), and financial benefits. If possible, a meta-analysis was performed. In case of considerable heterogeneity among studies, a qualitative analysis was performed. RESULTS: Forty studies were eligible for data extraction, 34 in meta-analysis and 40 in qualitative analysis. The total sample size consisted of more than 2 million patients undergoing hip or knee arthroplasty, with a mean age of 66 years and with 60% of females. The methodological quality of the included studies ranged from average to good. The ERP had lower (S)AEs [relative risk (RR): 0.9, 95% confidence interval (CI): 0.8-1] and readmission rates (RR: 0.8, 95%CI: 0.7-1), and reduced LoS [median days 6.5 (0.3-9.5)], and showed similar or improved outcomes for functional recovery and PROMs compared to regular pathways. The analyses for readmission presented a statistically significant difference in the enhanced recovery pathway in favor of knee arthroplasties (P = 0.01). ERP were reported to be cost effective, and the cost reduction varied largely between studies (€109 and $20573). The overall outcomes of all studies reported using Grading of Recommendation, Assessment, Development and Evaluation, presented moderate or high quality of evidence. CONCLUSION: This study showed that implementation of ERP resulted in improved clinical and patient related outcomes compared to regular pathways in hip and knee arthroplasty, with a potential reduction of costs.

4.
J Clin Med ; 11(2)2022 Jan 13.
Article in English | MEDLINE | ID: mdl-35054075

ABSTRACT

Periprosthetic joint infection (PJI) is a devastating complication in total hip and knee replacement. Its prevention is key to decrease the incidence and avoid some consequences that seriously impact patients and health systems. In view of the variety of recommendations and guidelines, we decided to conduct an expert, peer-reviewed European consensus analysis about the pre-, intra-, and postoperative prevention of PJI. A multinational group of practicing orthopedic experts developed a series of 47 consensus statements in 6 main groups of intervention, and a 2-stage Delphi approach was launched with a threshold for agreement at 75% and for very high agreement at more than 90%. A total of 306 orthopedic surgeon responses were gathered from 9 countries. Consensus was reached for 42/47 statements, 31/47 of which achieved a very high consensus. Many preoperative actions gathered strong consensus, although areas like the use of alcoholic chlorhexidine or the timing of hair removal did not attain strong consensus, despite available evidence. Intra- and postoperative actions showed more variability regarding incise drapes, skin suturing techniques, and wound follow-up. This study confirms an important consensus among orthopedic surgeons across Europe in many areas well known to contribute to the prevention of PJI; however, there are still grounds for improvement.

5.
Knee Surg Sports Traumatol Arthrosc ; 30(3): 918-927, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33570699

ABSTRACT

PURPOSE: The aim of this two-centre RCT was to compare pre- and post-operative radiological, clinical and functional outcomes between patient-specific instrumentation (PSI) and conventional instrumented (CI) unicompartmental knee arthroplasty (UKA). It was hypothesised that both alignment methods would have comparable post-operative radiological, clinical and functional outcomes. METHODS: One hundred and twenty patients were included, and randomly allocated to the PSI or the CI group. Outcome measures were peri-operative outcomes (operation time, length of hospital stay and intra-operative changes of implant size) and post-operative radiological outcomes including the alignment of the tibial and femoral component in the sagittal and frontal plane and the hip-knee-ankle-axis (HKA-axis), rate of adverse events (AEs) and patient-reported outcome measures (PROMs) pre-operatively and at 3, 12 and 24 months post-operatively. RESULTS: There was a statistically significant difference (p < 0.05) in alignment of the femoral component in the frontal plane in favour of the CI method. No statistically significant differences were found for the peri-operative data or in the functional outcome at 2-year follow-up. In the PSI group, the approved implant size of the femoral component was correct in 98.2% of the cases and the tibial component was correct in 60.7% of the cases. There was a comparable rate of AEs: 5.1% in the CI and 5.4% in the PSI group. CONCLUSION: The PSI method did not show an advantage over CI in regard of positioning of the components, nor did it show an improvement in clinical or functional outcome. We conclude that the possible advantages of PSI do not outweigh the costs of the MRI scan and the manufacturing of the PSI. LEVEL OF EVIDENCE: Randomised controlled trial, level I.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Surgery, Computer-Assisted , Arthroplasty, Replacement, Knee/methods , Humans , Knee Joint/surgery , Osteoarthritis, Knee/etiology , Osteoarthritis, Knee/surgery , Prospective Studies
6.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2654-2665, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33646370

ABSTRACT

PURPOSE: To determine whether patient-specific instrumentation (PSI), computer-assisted surgery (CAS) or robot-assisted surgery (RAS) enable more accurate rotational alignment of the tibial baseplate in primary total knee arthroplasty (TKA) compared to conventional instrumentation, in terms of deviation from the planned target and the proportion of outliers from the target zone. METHODS: The authors independently conducted three structured electronic literature searches using the PubMed, Embase®, and Cochrane Central Register of Controlled Trials databases from 2007 to 2020. Studies were included if they compared rotational alignment of the tibial baseplate during TKA using conventional instrumentation versus PSI, CAS, and/or RAS, and reported deviation from preoperatively planned rotational alignment of the tibial baseplate in terms of absolute angles and/or number of outliers. Methodological quality of eligible studies was assessed by two researchers according to the Downs and Black Quality Checklist for Health Care Intervention Studies. RESULTS: Fifteen studies, that reported on 2925 knees, were eligible for this systematic review, of which 6 studies used PSI, and 9 used CAS. No studies were found for RAS. Of the studies that reported on angular deviation from preoperatively planned rotational alignment, most found smaller deviations using PSI (0.5° to 1.4°) compared to conventional instrumentation (1.0° to 1.6°). All studies that reported on proportions of outliers from a target zone (± 3°), found lower rates of outliers using PSI (0 to 22%) compared to conventional instrumentation (5 to 96%). Most studies reported smaller angular deviation from preoperatively planned rotational alignment using CAS (0.1° to 6.9°) compared to conventional instrumentation (1.1° to 7.8°). Of the studies that reported on proportions of outliers from a target zone (± 3°), most found fewer outliers using CAS (10 to 61%) compared to conventional instrumentation (17 to 78%). CONCLUSION: This systematic review and meta-analysis revealed that both CAS and PSI can improve the accuracy of rotational alignment of the tibial baseplate by decreasing angular deviation from the preoperatively planned target and reducing the proportion of outliers from the target zone. The clinical relevance is that PSI and CAS can improve alignment, though the thresholds necessary to grant better outcomes and survival remain unclear. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Surgery, Computer-Assisted , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Rotation , Tibia/surgery
7.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2639-2653, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33666686

ABSTRACT

PURPOSE: The purpose of this systematic overview was to identify, synthesise and critically appraise findings of meta-analyses on robot-assisted versus conventional unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The hypothesis was that robotic assistance would reduce complications and revision rates, yield better clinical scores, and improve component positioning and alignment. METHODS: Two researchers independently conducted a literature search using Embase®, MEDLINE®, Web of Science, Allied and Complementary Medicine™ and Cochrane Database of Systematic Reviews on 2 November 2020 for meta-analyses (Level I-IV) on robotic assistance in UKA and/or TKA. Outcomes were tabulated and reported as weighted mean difference (WMD), risk ratio (RR) or weighted odds ratio (WOR), and were considered statistically significant when p < 0.05. RESULTS: A total of ten meta-analyses were identified; four on robot-assisted UKA (n, 1880 robot-assisted vs. 2352 conventional UKA; follow-up, 0 to 60 months), seven on robot-assisted TKA (n, 4567 robot-assisted vs. 5966 conventional TKA; follow-up, 0 to 132 months). Of the meta-analyses on UKA, one found that robotic assistance reduced complication rates (relative risk (RR), 0.62), one found that it improved clinical scores (weighted mean difference (WMD), 19.67), three found that it extended operation times (WMD, 15.7 to 17.1 min), and three found that it improved component positioning and alignment (WMD, - 1.30 to - 3.02 degrees). Of the meta-analyses on TKA, two found that robotic assistance improved clinical scores (WMD, 1.62-1.71), two found that that it extended surgery times (WMD, 21.5-24.26 min), and five found that it improved component positioning and alignment (WMD, - 0.50 to - 10.07 degrees). None of the meta-analyses reported differences in survivorship between robot-assisted versus conventional knee arthroplasty. CONCLUSION: Robot-assisted knee arthroplasty enabled more accurate component positioning and placement within target zones, but extended operation time considerably. Although robotic assistance improved component positioning, its benefits regarding clinical scores, patient satisfaction and implant survivorship remains to be confirmed. Finally, this overview revealed that six of the ten meta-analyses were of 'critically low quality', calling for caution when interpreting results. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Robotic Surgical Procedures , Arthroplasty, Replacement, Knee/methods , Humans , Knee Joint/surgery , Meta-Analysis as Topic , Osteoarthritis, Knee/surgery , Reoperation , Robotic Surgical Procedures/methods , Treatment Outcome
8.
Knee Surg Sports Traumatol Arthrosc ; 30(12): 3968-3982, 2022 Dec.
Article in English | MEDLINE | ID: mdl-34792611

ABSTRACT

PURPOSE: The purpose of this systematic review was to synthesise the available literature and critically appraise current evidence on the functional and radiographic outcomes as well as reoperation and revision rates of custom partial knee arthroplasty, i.e., unicompartmental knee arthroplasty (UKA), bicompartmental knee arthroplasty (BKA), and patellofemoral arthroplasty (PFA). MATERIAL AND METHODS: This systematic review was performed in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), and a protocol was registered with Prospero. On 25 May 2021, two authors independently searched and screened Level I-IV studies that reported on outcomes of custom partial knee arthroplasty using the databases of MEDLINE®, EMBASE®, and the Cochrane Library without restriction on date of publication. Findings from eligible articles were synthesised and tabulated, and quality assessments were done according to the guidelines of the Joanna Briggs Institute (JBI) Checklists. RESULTS: Fifteen articles were eligible for data extraction, of which two comparative and four case series were on custom UKA (follow-up, 0-9 months), one comparative and five case series on custom BKA (follow-up, 0.25-72 months), and three case series on custom PFA (follow-up, 2-119 months). Three studies on custom UKA reported mean Knee Society Score (KSS) Knee of 86-94 and mean KSS Function of 94-95, and two studies on custom BKA reported mean KSS Knee of 90-94 and KSS function of 81, whereas one study on custom PFA reported KSS Knee of 91 and KSS Function of 89. Custom implants tended to have less bone-implant mismatch compared to off the shelf (OTS) implants. Revision rates were 3-25% for custom UKA (at 0-109 months), 3-5% for custom BKA (at 12-72 months), and 0-14% for custom PFA (at 2-119 months). CONCLUSION: Due to the small number of comparative studies and lack of consistency in reported outcomes, it remains difficult to ascertain the benefits of custom partial knee arthroplasty. Anecdotal evidence suggests that, compared to OTS implants, custom implants result in less bone-implant mismatch and that 78-91% of patients are either satisfied or very satisfied after custom partial knee arthroplasty. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Treatment Outcome
9.
Knee Surg Sports Traumatol Arthrosc ; 29(10): 3159-3163, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33433635

ABSTRACT

PURPOSE: During the COVID-19 pandemic there has been a massive reduction of arthroplasty services due to reallocation of hospital resources. The unique challenge for clinicians has been to define which arthroplasty patients most urgently require surgery. The present study aimed to investigate priority arthroplasty procedures during the pandemic and in the reinstatement period from the surgeon's perspective. MATERIAL AND METHODS: An online survey was conducted among members of the European Hip Society (EHS), European Knee Associates (EKA) and other invited orthopaedic arthroplasty surgeons (experts) from across the world. The survey consisted of 17 different arthroplasty procedures/indications of which participants were asked to choose and rank the most important 10. RESULTS: Four hundred and thirty-nine arthroplasty surgeons from 44 countries responded. The EHS and EKA had a 43% response rate of members. In weighted average points, the majority of respondents (67.5 points) ranked 'acute fractures requiring arthroplasty (Periprosthetic fractures, THA/hemi-arthroplasty for femoral neck fractures)' as priority indication number one, followed by 'first-stage explantations for acute PJI (periprosthetic joint infection)' in second place and priority indication (45.9 points) three as 'one-stage revision for acute PJI' (39.7 points). CONCLUSIONS: There was agreement that femoral neck fractures, periprosthetic fractures, and acute infections should be prioritised and cannot be postponed in the setting of the COVID-19 pandemic. As arthroplasty procedures are being resumed in most countries now, there has also been a relaxation of lockdown rules in most countries, which might cause a so-called second wave of the pandemic. Therefore, the results of the current study present a proposal by experts as to which operations should be prioritised in the setting of a second wave of the pandemic.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , COVID-19 , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Communicable Disease Control , Humans , Pandemics , Reoperation , SARS-CoV-2 , Surveys and Questionnaires
10.
Knee Surg Sports Traumatol Arthrosc ; 29(3): 694-709, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33404817

ABSTRACT

PURPOSE: To elaborate recommendations for sports participation following TKA among the members of the European Knee Associates (EKA). METHODS: A prospective online survey was conducted among the members of the European Knee Associates (EKA). The European Knee Associates (EKA) are a section of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA). The survey investigated recommendations for 47 sports disciplines. Possible answers were: allowed, allowed if experienced, not allowed, no opinion. The survey was conducted separately for 4 specific time frames: within 6 weeks after TKA; 6-12 weeks after TKA; 3-6 months after TKA; and more than 6 months after TKA. Consensus among the respondents was then analyzed. RESULTS: EKA members (N = 120) participated in the survey. A high level of consensus was reached for a recommendation to allow 5 different sports in the first 6 weeks after TKA, 7 sports 6-12 weeks after surgery, 14 sports 3-6 months after TKA, and 21 out of 47 activities 6 months after surgery. In the first 6 weeks after TKA walking, stair climbing, swimming, aqua fitness, and static cycling were recommended. Six to twelve weeks after TKA, cycling on level ground and yoga were recommended in addition to the aforementioned activities. Further sports activities recommended beyond 12 weeks after TKA were: tennis doubles, golf, fitness/weight lifting, aerobics, hiking, Nordic walking and sailing. The sport for which the recommendation was "not allowed" following TKA was squash. CONCLUSION: The number of sports recommended by EKA surgeons increases stepwise over the postoperative time frames. The findings are regarded as clinically relevant as they may serve as a basis for answering patient questions on timing and giving recommendations for the resumption of sports activities following standard primary TKA and should be individualized by surgeons for their patients' expectations and goals. LEVEL OF EVIDENCE: V.


Subject(s)
Arthroplasty, Replacement, Knee/rehabilitation , Exercise , Return to Sport , Sports , Arthroplasty, Replacement, Knee/methods , Bicycling , Europe , Female , Golf , Humans , Knee Joint/surgery , Male , Postoperative Period , Prospective Studies , Societies, Medical , Surveys and Questionnaires , Swimming , Tennis , Walking , Yoga
11.
EFORT Open Rev ; 6(12): 1157-1165, 2021 Dec 10.
Article in English | MEDLINE | ID: mdl-35839094

ABSTRACT

Robot-assisted total hip arthroplasty (THA), in comparison to conventional THA, improves radiographic outcomes, but it remains unclear whether it alters complication rates, clinical and functional outcomes, and implant survival. The purpose of this systematic overview was to summarize the findings of the most recent meta-analyses that compare clinical and surgical outcomes of robot-assisted versus conventional THA. Two readers independently conducted an electronic literature search, screening and data extraction from five electronic databases. Inclusion criteria were: meta-analyses evaluating robot-assisted versus conventional THA in terms of radiographic outcomes, clinical and functional scores, and complications and revision rates. The literature search returned 67 records, of which 14 were duplicates and 49 were excluded, leaving three meta-analyses published within the past two years for data extraction and analysis. The present overview of meta-analyses suggests that, compared to conventional THA (n = 3011), robot-assisted THA (n = 1813) improves component placement and reduces intraoperative complications. The overview also affirms that robot-assisted THA could extend surgery by 20 minutes, and increases risks of postoperative heterotopic ossification, dislocation, and revision. None of the meta-analyses found significant differences in clinical or functional scores between robot-assisted and conventional THA. Future studies and reviews should make a clear distinction between active and semi-active robotic assistance, address technology matureness, and describe the experience of surgeons with robotic assistance.

12.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 573-578, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32232539

ABSTRACT

PURPOSE: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses individually designed disposable guides to determine intraoperative bone cuts. The manufacturer provides the surgeon with proposed planning which can be modified and should be approved by the surgeon before the guides are produced. This study aims to assess the intra- and inter-observer reliability among preoperative planning by orthopaedic surgeons using PSI. The authors hypothesize a high intra- and inter-observer reliability in planning TKA using PSI. METHODS: Four orthopaedic surgeons modified and approved 40 preoperative MRI-based PSI plannings three times. The surgeons were blinded to their own and each other's results. Intra- and inter-observer reliability was obtained for planned implant size, resection, and position of the implant. RESULTS: Intra-observer reliability Intraclass Correlation Coefficients (ICC) were excellent for femoral and tibial implant size with a range of 0.948-0.995 and 0.919-0.988, respectively. Inter-observer reliability for femoral and tibial implant size showed an ICC range of 0.953-0.982 and 0.839-0.951, respectively. Next to implant size, intra- and inter-observer reliability demonstrated good to an excellent agreement (ICC > 0.75) for 7 out of 12 remaining parameters and 6 out of 12 remaining parameters, respectively. CONCLUSION: Preoperative planning of TKA implant size using MRI-based PSI showed excellent intra- and inter-observer reliability. Further research on the comparison of predicted implant size preoperatively to intraoperative results is needed.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Observer Variation , Patient Care Planning , Prosthesis Design , Arthroplasty, Replacement, Knee/methods , Femur/surgery , Humans , Knee Joint/surgery , Magnetic Resonance Imaging , Orthopedic Surgeons , Tibia/surgery
13.
Global Spine J ; 11(7): 1032-1039, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32677523

ABSTRACT

STUDY DESIGN: Retrospective cohort study. OBJECTIVES: Total disc replacement (TDR) has been introduced in order to preserve segmental motion and thus reduce adjacent segment disease (ASD) as seen after spinal fusion. However, it is uncertain whether these presumed beneficial effects remain. The aim of this study was to evaluate the long-term incidence of ASD and residual-mobility in relation to clinical outcome. METHODS: A total of 210 patients treated with lumbar TDR for degenerative disc disease were invited for follow-up. ASD was reported in case of severe degeneration in an adjacent disc at latest follow-up, or if an increase in disc degeneration was observed in these adjacent segments as compared to direct postoperative radiographs. Residual-mobility of the TDR was defined as a minimal rotation of 4.6° on flexion-extension radiographs. Patient-reported outcome measures were obtained. RESULTS: Fifty-seven patients (27.1%) were lost to follow-up. In 32 patients (15.3%) a revision by spinal fusion had been performed. In 20 patients this revision had occurred ≥5 years after TDR and were included. Consequently, 141 patients were available for analysis (mean follow-up of 16.7 years). Residual-mobility was noted in 38.0%. No significant associations were observed between residual-mobility and the occurrence of ASD, or with clinical outcome. In addition, ASD and clinical outcome were not related either. CONCLUSIONS: It appears that long-term preservation of motion after TDR is met for only a third of patients. However, residual-mobility is not associated with the occurrence of ASD, and both residual-mobility and ASD do not appear to be related to long-term clinical outcome.

14.
Trop Med Infect Dis ; 5(4)2020 Dec 11.
Article in English | MEDLINE | ID: mdl-33322463

ABSTRACT

Background: Periprosthetic joint infection (PJI) represents 25% of failed total knee arthroplasties (TKA). The European Knee Associates (EKA) formed a transatlantic panel of experts to perform a literature review examining patient-related risk factors with the objective of producing perioperative recommendations in PJI high-risk patients. Methods: Multiple databases (Pubmed/MEDLINE, EMBASE, Scopus, Cochrane Library) and recommendations on TKA PJI prevention measures from the International Consensus Meetings on PJI from the AAOS and AAHKS were reviewed. This represents a Level IV study. Results: Strong evidence was found on poor glycemic control, obesity, malnutrition, and smoking being all associated with increased rates of PJI. In the preoperative period, patient optimization is key: BMI < 35, diet optimization, Hemoglobin A1c < 7.5, Fructosamine < 292 mmol/L, smoking cessation, and MRSA nasal screening all showed strong evidence on reducing PJI risk. Intraoperatively, a weight-based antibiotic prophylaxis, accurate fluid resuscitation, betadine and chlorhexidine dual skin preparation, diluted povidone iodine solution irrigation, tranexamic acid administration, and monofilament barbed triclosan-coated sutures for soft tissues closure all represented effective prevention measures. In the postoperative period, failure to reach normalization of ESR, CRP, D-dimer, and IL-6 six weeks postoperatively suggested early PJI. Conclusion: The current recommendations from this group of experts, based on published evidence, support risk stratification to identify high-risk patients requiring implementation of perioperative measures to reduce postoperative PJI.

15.
Knee Surg Sports Traumatol Arthrosc ; 28(9): 2747-2755, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32803277

ABSTRACT

PURPOSE: To plan for the continuance of elective hip and knee arthroplasty during a resurgence or new wave of COVID-19 infections. METHOD: A systematic review was conducted using the terms "COVID-19" or "SARS-Cov-2" and "second wave". No relevant citations were found to inform on recommendations the plan. Therefore, an expert panel of the European Hip Society and the European Knee Associates was formed to provide the recommendations. RESULTS: Overall, the recommendations consider three phases; review of the first wave, preparation for the next wave, and during the next wave. International and national policies will drive most of the management. The recommendations focus on the preparation phase and, in particular, the actions that the individual surgeon needs to undertake to continue with, and practice, elective arthroplasty during the next wave, as well as planning their personal and their family's lives. The recommendations expect rigorous data collection during the next wave, so that a cycle of continuous improvement is created to take account of any future waves. CONCLUSIONS: The recommendations for planning to continue elective hip and knee arthroplasty during a new phase of the SARS-Cov-2 pandemic provide a framework to reduce the risk of a complete shutdown of elective surgery. This involves engaging with hospital managers and other specialities in the planning process. Individuals have responsibilities to themselves, their colleagues, and their families, beyond the actual delivery of elective arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Coronavirus Infections/epidemiology , Elective Surgical Procedures/methods , Pneumonia, Viral/epidemiology , Betacoronavirus , COVID-19 , Europe , Humans , Orthopedics , Pandemics , SARS-CoV-2 , Societies, Medical , Surgeons
16.
Hip Int ; 30(5): 492-499, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32635761

ABSTRACT

Reinstating elective hip and knee arthroplasty services presents significant challenges. We need to be honest about the scale of the obstacles ahead and realise that the health challenges and economic consequences of the COVID-19 pandemic are potentially devastating.We must also prepare to make difficult ethical decisions about restarting elective hip and knee arthroplasty. These decisions should be based on the existing evidence-base, reliable data, the recommendations of experts, and regional circumstances.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Betacoronavirus , Coronavirus Infections/epidemiology , Delivery of Health Care , Pneumonia, Viral/epidemiology , COVID-19 , Coronavirus Infections/prevention & control , Coronavirus Infections/transmission , Elective Surgical Procedures , Humans , Pandemics/prevention & control , Patient Selection , Pneumonia, Viral/prevention & control , Pneumonia, Viral/transmission , SARS-CoV-2
17.
J Exp Orthop ; 7(1): 52, 2020 Jul 19.
Article in English | MEDLINE | ID: mdl-32686011

ABSTRACT

PURPOSE: To provide evidence-based recommendations for patients with severe knee osteoarthritis (OA), who had their knee surgery postponed due to the COVID-19 pandemic. METHODS: PubMed/Medline, Scopus and Cochrane Central databases were systematically reviewed for studies reporting outcomes of home-based treatments for knee OA. Due to between-study differences in treatment strategy and reporting methods the results were not pooled and findings of the current review were presented in a narrative manner. RESULTS: The comprehensive literature search yielded 33 eligible studies that were included in this review. Management is performed at home and consists of exercise, proper nutrition, physical therapy and use of corrective and assistive orthotics. Virtual education on self-management strategies should be part of coping with knee OA. Initiating an exercise programme involving gymnastics, stretching, home cycling and muscle strengthening is highly recommended. Obese patients are encouraged to set weight loss goals and adopt a healthy diet. Potential benefits but weak evidence has been shown for the use of knee braces, sleeves, foot orthotics or cushioned footwear. Walking aids may be prescribed, when considered necessary, along with the provision of instructions for their use. CONCLUSION: When bridging the time to rescheduled surgery, it is essential to use appropriate home-based tools for the management of knee OA if pain is to be reduced and need for analgesics or opioid use is to be diminished while maintaining or even improving the functioning and avoiding further limitation of range of motion and subsequent muscular atrophies. Finally, none of these treatments may completely substitute for the life-changing effect of a total knee arthroplasty in patients with severe knee OA. Hence, the subsequent goal is to gradually and safely reinstate elective surgery.

18.
Knee Surg Sports Traumatol Arthrosc ; 28(6): 1821-1826, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31270591

ABSTRACT

PURPOSE: Patient-specific instruments (PSI) are already widespread used in total knee arthroplasty (TKA). Either computed tomography (CT) scans or magnetic resonance imaging (MRI) scans are used pre-operatively to create jigs to guide resection during surgery. This study is a sequel of previous work that showed significantly more radiological outliers for posterior slope when CT-based guides were used. The aim of this study was to assess differences in revision rate and clinical outcome between the two groups at 2-year follow-up. METHODS: At the 2-year follow-up, 124 patients were analysed in this prospective, randomised single-blind study. A survival analysis with revision of the TKA as endpoint was performed. Patients fulfilled four patient-reported outcome measurements (PROMs). Scores on the questionnaires were compared between both groups at the different follow-up visits. RESULTS: At final follow-up, there was no significant difference in the survival rates of the CT- and MRI-based PSI surgery. Postoperatively, the PROMs significantly improved within each group compared with the pre-operative values. There were no significant differences for the PROMs between both groups at the 2-years follow-up. CONCLUSIONS: Although previous results showed more outliers regarding posterior slope for CT-based PSIs, no difference in revision rate or the outcome of PROMs was found at 2-year follow-up. Further research to determine what the influence is of radiological outliers on implant survival and clinical outcomes is necessary. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Equipment Failure Analysis , Knee Prosthesis , Magnetic Resonance Imaging , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed , Female , Follow-Up Studies , Humans , Knee Joint/surgery , Male , Osteoarthritis, Knee/surgery , Patient Reported Outcome Measures , Prospective Studies , Reoperation , Single-Blind Method
19.
Knee Surg Sports Traumatol Arthrosc ; 27(4): 1204-1212, 2019 Apr.
Article in English | MEDLINE | ID: mdl-29725749

ABSTRACT

PURPOSE: Despite multimodal pain management and advances in anesthetic techniques, total knee arthroplasty (TKA) remains painful during the early postoperative phase. This trial investigated whether computer-assisted cryotherapy (CAC) is effective in reduction of pain and consumption of opioids in patients operated for TKA following an outpatient surgery pathway. METHODS: Sixty patients scheduled for primary TKA were included in this prospective, double-blind, randomized controlled trial receiving CAC at 10-12 °C (Cold-group, n = 30) or at 21 °C (Warm-group, n = 30) during the first 7 days after TKA according to a fixed schedule. All patients received the same pre-, peri- and postoperative care with a multimodal pain protocol. Pain was assessed before and after every session of cryotherapy using the numerical rating scale for pain (NRS-pain). The consumption of opioids was strictly noted during the first 4 postoperative days. Secondary outcomes were knee swelling, visual hematoma and patient reported outcome measures (PROMs). These parameters were measured pre-, 1, 2 and 6 weeks postoperatively. RESULTS: In both study groups, a reduction in NRS-pain after every CAC session were seen during the postoperative period of 7 days. A mean reduction of 0.9 and 0.7 on the NRS-pain was seen for respectively the Cold- (P = 0.008) and Warm-group (n.s.). A significant (P = 0.001) lower number of opioids were used by the Cold-group during the acute postoperative phase of 4 days, 47 and 83 tablets for respectively the Cold and Warm-group. No difference could be observed for secondary outcomes and adverse effects between both study groups. CONCLUSIONS: Postoperative CAC can be in added value in patients following an outpatient surgery pathway for TKA, resulting in reduced experienced pain and consumption of opioids during the first postoperative days.


Subject(s)
Analgesics, Opioid/administration & dosage , Arthroplasty, Replacement, Knee/adverse effects , Cryotherapy/adverse effects , Pain, Postoperative/drug therapy , Patient Reported Outcome Measures , Surgery, Computer-Assisted/methods , Aged , Dose-Response Relationship, Drug , Double-Blind Method , Female , Humans , Male , Middle Aged , Pain Management , Pain Measurement , Pain, Postoperative/diagnosis , Pain, Postoperative/etiology , Prospective Studies , Range of Motion, Articular
20.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1656-1661, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28785788

ABSTRACT

PURPOSE: Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. METHODS: An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations >3.0° from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. RESULTS: The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1° (1.4°). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. CONCLUSIONS: This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. LEVEL OF EVIDENCE: Prospective cohort study, Level II.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Bone Malalignment/surgery , Femur/surgery , Joint Diseases/surgery , Reoperation/instrumentation , Aged , Biomechanical Phenomena , Bone Malalignment/etiology , Female , Femur/diagnostic imaging , Femur/physiopathology , Humans , Joint Diseases/physiopathology , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee Prosthesis , Male , Middle Aged , Patient-Specific Modeling , Prospective Studies , Reoperation/methods , Rotation , Surgery, Computer-Assisted , Tibia/diagnostic imaging , Tibia/physiopathology , Tibia/surgery , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...