Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biocontrol Sci ; 25(1): 9-16, 2020.
Article in English | MEDLINE | ID: mdl-32173667

ABSTRACT

Healthcare workers should wear appropriate personal protective clothing (PPC) on assuming the risk of exposure to various pathogens. Therefore, it is important to understand PPC performance against pathogen penetration. Currently, standard methods to evaluate and classify the penetration resistance of PPC fabrics with pressure using synthetic blood or phi-X174 phage have been established by the International Organization for Standardization (ISO). However, the penetration of viral liquid drops (VLDrop) on the PPC without pressure is also a major exposure route and more realistic, necessitating further studies. Here, we evaluated the penetration resistance against VLDrop without pressure using phi-X174 phage on woven and nonwoven fabrics of commercially available PPC classified by the ISO, and analyzed in detail the penetration behaviors of VLDrop by quantifying the phage amounts in leak-through and migration into test fabrics. Our results showed that some nonwoven test fabrics had nearly the same penetration resistance against VLDrop, even if the ISO resistance class differed. Furthermore, the results revealed that the amount of leakage through the fabrics was correlated with the migration amount into the fabric, which was related to fluid-repellency of fabrics, suggesting the effectiveness for penetration resistance. Our study may facilitate more appropriate selection for PPC against pathogen penetration.


Subject(s)
Personal Protective Equipment/virology , Protective Clothing/virology , Textiles/virology , Viruses/pathogenicity , Bacteriophage phi X 174/pathogenicity , Materials Testing/methods
2.
Front Public Health ; 7: 121, 2019.
Article in English | MEDLINE | ID: mdl-31179258

ABSTRACT

Personal protective gowns and coveralls are classified based on barrier efficiency that validates protection from fluid penetration under certain pressures. Materials standardized in this system have been found suitable for emergency medical practices confronting highly contagious diseases. Nevertheless, adhesion of blood, and body fluids from virus-infected patients to the surface of protective clothing still imposes a risk of pathogen transmission in the process of doffing, or undressing. We performed a small-scale experiment to test the possibility of infectious virus carryover on the surface of different fabrics used in commercially available protective gowns. Application of a lentivirus vector that expresses green fluorescent protein allowed easy monitoring of infectious viral loads on fabrics. Results indicate that fabrics of level-3 surgical gowns serve better to reduce virus transmission compared to fabrics of chemical protective clothing with the same or higher barrier efficiency. Analysis of sliding angles provided indexes of fluid repellency, which were inversely related to virus carryover potentials. Droplets of infectious body fluids may easily roll off fabrics with water-repellent finishing. Thus, virus carryover is a measurable risk factor to be considered for better choice of personal protective clothing.

SELECTION OF CITATIONS
SEARCH DETAIL
...