Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Catheter Cardiovasc Interv ; 101(4): 713-721, 2023 03.
Article in English | MEDLINE | ID: mdl-36841946

ABSTRACT

BACKGROUND: Target lumen enlargement (TLE) or "late lumen enlargement" is often encountered after percutaneous coronary intervention (PCI) with drug-coated balloons (DCB). To date, the prognosis of coronary arterial lesions with or without TLE has not been clearly elucidated. AIMS: This study aimed to assess the long-term prognosis of coronary arterial lesions with or without TLE observed within 1 year (early TLE) after DCB angioplasty using serial quantitative angiographic follow-up. METHODS: One hundred and ninety-three consecutive patients (de novo coronary arterial lesions, 251) who underwent follow-up angiography within 1 year after DCB angioplasty (early follow-up, median: 6 months) were retrospectively evaluated. Of these, 97 patients (125 lesions) also underwent angiography more than 1 year after DCB angioplasty (late follow-up, median: 37 months). TLE was defined as an increase in minimal lumen diameter (MLD) after PCI at each follow-up. RESULTS: Early TLE was detected in 142 lesions (56.6%). Of these, 76 lesions were also evaluated at late follow-up. TLE persisted even at late follow-up in 67 of the 76 lesions (88.2%). An increase in MLD in early TLE (+) lesions was observed in the period between post-PCI and early follow-up (1.84 ± 0.06 vs. 2.12 ± 0.07 mm, p < 0.001) but not between early and late follow-up (2.12 ± 0.07 vs. 2.16 ± 0.07 mm, p = 0.74). In contrast, 49 of 109 lesions without early TLE were evaluated at late follow-up, of which 28 lesions (57.1%) showed TLE at late follow-up. The MLD of early TLE (-) lesions (n = 49) significantly increased from early (1.63 ± 0.061 mm) to late follow-up (1.84 ± 0.06 mm) (p < 0.001). No aneurysms were found in any of these cases. CONCLUSION: Early TLE was observed in more than half of the lesions, with the majority remaining at late follow-up. Alternatively, half of the lesions without early TLE showed late TLE, occurring biphasically after DCB angioplasty.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Coronary Restenosis , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/surgery , Retrospective Studies , Coronary Angiography , Treatment Outcome , Coated Materials, Biocompatible
2.
Int J Cardiol ; 86(1): 71-6, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12243851

ABSTRACT

BACKGROUND: Reduced or impaired synthesis of nitric oxide promotes the proliferation of vascular smooth muscle cells, and thus may induce the neointimal formation leading to coronary in-stent restenosis. Recent reports have suggested that the Glu298Asp polymorphism in exon 7 of the endothelial nitric oxide synthase gene is associated with coronary spasm and acute myocardial infarction. In this study, we have examined the implication of this polymorphism with regard to coronary restenosis after Palmaz-Schatz stent deployment. METHODS: Eighty-nine lesions in 85 consecutive patients were treated with Palmaz-Schatz stents, and were prospectively followed up for 6 months. The lesions were classified into a restenosis group (% diameter stenosis=50%) and a non-restenosis group. Assessment was made using an automated quantitative angiographic system. We performed polymerase chain reaction-restriction fragment length polymorphism analysis to detect the missense Glu298Asp variant in exon 7 of the endothelial nitric oxide synthase gene. RESULTS: Coronary risk factors and angiographic findings of stenotic lesions did not differ between the groups. Univariate analyses showed that the missense Glu298Asp variant was the only statistically significant predictor of restenosis (odds ratio, 4.27; P=0.025). In addition, multiple logistic regression analysis revealed the missense Glu298Asp variant as the only independent predictor for in-stent restenosis (odds ratio, 3.90; P=0.036). CONCLUSIONS: The missense Glu298Asp variant may be an independent risk factor for in-stent restenosis.


Subject(s)
Coronary Restenosis/genetics , Endothelium, Vascular/enzymology , Nitric Oxide Synthase/genetics , Aged , Aged, 80 and over , Aspartic Acid/genetics , Female , Genotype , Glutamic Acid/genetics , Humans , Logistic Models , Male , Middle Aged , Mutation, Missense , Polymerase Chain Reaction , Polymorphism, Genetic , Polymorphism, Restriction Fragment Length , Stents/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...