Anal Chem ; 93(24): 8508-8516, 2021 06 22.
Article in English | MEDLINE | ID: mdl-34100587

ABSTRACT

We demonstrate microfluidic automation and parallelization of Limulus amebocyte lysate (LAL)-based bacterial endotoxin testing using centrifugal microfluidics. LAL is the standard reagent to test for endotoxin contaminations in injectable pharmaceuticals. The main features of the introduced system are more than 90% reduction of LAL consumption, from 100 µL/reaction to 9.6 µL/reaction, automated liquid handling to reduce opportunities for contamination and manual handling errors, and microfluidic parallelization by integrating 104 reactions into a single centrifugal microplate. In a single Eclipse microplate, 21 samples and their positive product controls are tested in duplicate. In addition, a standard curve with up to five points is generated, resulting in a total of 104 reactions. Test samples with a defined concentration of 0.5 endotoxin units per milliliter were tested, resulting in a coefficient of variation below 0.75%. A key feature for achieving a small coefficient of variation is ensuring the same path length along the microfluidic channels to the final reaction chambers for each sample and the reagent, so that any unspecific adsorption to the polymer surfaces does not affect the accuracy and precision. Analysis of a sample containing naturally occurring endotoxin with the developed microfluidic microplate yielded comparable results to the conventional testing method. A test with eight commercially available pharmaceuticals was found to pass all requirements for bacterial endotoxin testing as specified in the United States Pharmacopeia. The automated endotoxin testing system reveals specific advantages of centrifugal microfluidics for analytical biochemistry applications. Small liquid volumes are handled (metered, mixed, and aliquoted) in a very precise, highly integrated, and highly parallel manner within mass-fabricated microplates.


Subject(s)
Endotoxins , Limulus Test , Automation , Microfluidics , Miniaturization
2.
Lab Chip ; 16(7): 1161-70, 2016 Apr 07.
Article in English | MEDLINE | ID: mdl-26931639

ABSTRACT

We present a centrifugal microfluidic LabDisk for protein structure analysis via small-angle X-ray scattering (SAXS) on synchrotron beamlines. One LabDisk prepares 120 different measurement conditions, grouped into six dilution matrices. Each dilution matrix: (1) features automatic generation of 20 different measurement conditions from three input liquids and (2) requires only 2.5 µl of protein solution, which corresponds to a tenfold reduction in sample volume in comparison to the state of the art. Total hands on time for preparation of 120 different measurement conditions is less than 5 min. Read-out is performed on disk within the synchrotron beamline P12 at EMBL Hamburg (PETRA III, DESY). We demonstrate: (1) aliquoting of 40 nl aliquots for five different liquids typically used in SAXS and (2) confirm fluidic performance of aliquoting, merging, mixing and read-out from SAXS experiments (2.7-4.4% CV of protein concentration). We apply the LabDisk for SAXS for basic analysis methods, such as measurement of the radius of gyration, and advanced analysis methods, such as the ab initio calculation of 3D models. The suitability of the LabDisk for SAXS for protein structure analysis under different environmental conditions is demonstrated for glucose isomerase under varying protein and NaCl concentrations. We show that the apparent radius of gyration of the negatively charged glucose isomerase decreases with increasing protein concentration at low salt concentration. At high salt concentration the radius of gyration (Rg) does not change with protein concentrations. Such experiments can be performed by a non-expert, since the LabDisk for SAXS does not require attachment of tubings or pumps and can be filled with regular pipettes. The new platform has the potential to introduce routine high-throughput SAXS screening of protein structures with minimal input volumes to the regular operation of synchrotron beamlines.


Subject(s)
Microfluidic Analytical Techniques , Proteins/analysis , Proteins/chemistry , Scattering, Small Angle , X-Ray Diffraction/instrumentation , Centrifugation , Quantum Theory
3.
Biotechniques ; 57(3): 151-5, 2014.
Article in English | MEDLINE | ID: mdl-25209050

ABSTRACT

A method for conserving primers and differently labeled fluorogenic hydrolysis (i.e., TaqMan) probes at ambient conditions is presented. Primers and hydrolysis probes with four different fluorophore-quencher combinations (6- FAM-BHQ1, HEX-BHQ1, ROX-BHQ650, and Cy5-BHQ2) were mixed with trehalose and xanthan at final concentrations of 56 mM and 2.78 mM, respectively. Mixtures were air-dried at 23°C for 30 min on strips composed of cyclo olefin polymer (COP), a material widely used in the manufacturing of in vitro diagnostic (IVD) test carriers. After one year of storage, the functionality of the primers and fluorophore-quencher combinations was validated by real-time polymerase chain reaction (real-time PCR), confirming their stability when stored in the presence of stabilizers, with the best results achieved using trehalose. This approach could be of great benefit for manufacturing IVD systems, for example, for genotyping applications based on multiplexing using different fluorescent dyes.


Subject(s)
DNA Primers/chemistry , Excipients/chemistry , Polysaccharides, Bacterial/chemistry , Real-Time Polymerase Chain Reaction/methods , Trehalose/chemistry , Fluorescent Dyes , Hydrolysis , Reproducibility of Results
4.
Lab Chip ; 10(11): 1365-86, 2010 Jun 07.
Article in English | MEDLINE | ID: mdl-20369211

ABSTRACT

This critical review is motivated by an increasing interest of the microfluidics community in developing complete Lab-on-a-Chip solutions based on thin and flexible films (Lab-on-a-Foil). Those implementations benefit from a broad range of fabrication methods that are partly adopted from well-established macroscale processes or are completely new and promising. In addition, thin and flexible foils enable various features like low thermal resistance for efficient thermocycling or integration of easily deformable chambers paving the way for new means of on-chip reagent storage or fluid transport. From an economical perspective, Lab-on-a-Foil systems are characterised by low material consumption and often low-cost materials which are attractive for cost-effective high-volume fabrication of self-contained disposable chips. The first part of this review focuses on available materials, fabrication processes and approaches for integration of microfluidic functions including liquid control and transport as well as storage and release of reagents. In the second part, an analysis of the state of Lab-on-a-Foil applications is provided with a special focus on nucleic acid analysis, immunoassays, cell-based assays and home care testing. We conclude that the Lab-on-a-Foil approach is very versatile and significantly expands the toolbox for the development of Lab-on-a-Chip solutions.


Subject(s)
Biosensing Techniques/instrumentation , Biosensing Techniques/trends , Membranes, Artificial , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/trends , Equipment Design , Technology Assessment, Biomedical