Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biomedicines ; 11(2)2023 Jan 23.
Article in English | MEDLINE | ID: mdl-36830855

ABSTRACT

Accumulating evidence considers psoriasis a systemic inflammatory disorder that is associated with comorbidities such as psoriatic arthritis, cardiovascular disease, and metabolic syndrome. Although the precise pathogenetic links between psoriasis and atherosclerosis warrants further investigation, it is believed that chronic systemic inflammation along with the T helper (Th)-1 and Th17 polarization are associated with endothelial dysfunction and subsequent acceleration of atherosclerosis. Considering the above, several studies have evaluated if optimal control of the inflammation in psoriasis by inhibiting interleukins targeting the Interleukin (IL)-23/Th17 axis could subsequently reduce the atherosclerotic process during anti-psoriatic treatment by using a variety of surrogate markers of subclinical atherosclerosis. This systematic review summarizes current knowledge on the pathogenetic mechanisms and diagnostic evaluation of atherosclerosis in the context of psoriasis and provides a systematic review of the literature on the impact of treatment with biologics targeting the IL-23/Th17 axis on subclinical atherosclerosis in patients with plaque psoriasis and/or psoriatic arthritis.

3.
J Interv Card Electrophysiol ; 66(2): 471-481, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36063282

ABSTRACT

BACKGROUND: The strategy of cardiac implantable electronic device (CIED) implantations performed as day-case admissions has gained a wider acceptance overtime; however, data on safety are still limited. This study aims to investigate the safety of a same-day discharge protocol introduced in our hospital for the postprocedural management of patients undergoing CIED implantation. METHODS: Α prospective, non-interventional, non-randomised study performed in a single high-volume implanting centre for a 16-month period (March 2020 to June 2021). At total of 821 of 965 (85.1%) patients scheduled for elective CIED implantation were considered to be eligible for inclusion in the Short-stay Device Management Protocol. These patients were compared with a historical group of 932 patients, meeting the same inclusion criteria. RESULTS: Procedure was successful in 812 patients (98.9%), committed to same-day discharge versus 921 of 932 patients (98.8%) admitted for overnight stay (p = 0.87). Overall, 90-day complication rate was comparable in both groups (4.14% vs 4.07%, p = 0.95), as was major (1.46% vs. 1.82%, p = 0.55) and minor (2.67% vs. 2.25%, p = 0.64) complication rates. The composite early post-procedural complication rates and late post-procedural complication rates were comparable among groups (0.97 vs 1.18%, p = 0.70 and 0.73% vs 0.64%, p = 0.83, respectively). Six hundred sixty-seven patients (84%) preferred the same-day discharge strategy. Finally, a reduction of 792 bed-days was recorded, resulting in possible financial Health System benefits. CONCLUSIONS: Same-day discharge is feasible and safe in the majority of patients referred for CIED implantation. Additionally, same-day discharge is preferred by patients and may reduce procedure-related costs due to significant bed-day reductions.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Patient Discharge , Prospective Studies , Hospitalization , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...