Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int Orthop ; 33(4): 911-6, 2009 Aug.
Article in English | MEDLINE | ID: mdl-18509638

ABSTRACT

The purpose of this study was to evaluate the minimum five-year prospective results from the multicentre use of a porous tantalum monoblock acetabular component for primary total hip arthroplasty (THA). A multicentre study was performed in 253 consecutive primary THAs in three separate surgical centres. All patients underwent identical postoperative protocols including radiological and clinical evaluation. The average preoperative total HHS score was 44.0 +/- 13.8 and increased at one-year follow-up to 95.2 +/- 4.8 (p <0.05), remaining constant through the five-year follow-up at 97.0 +/- 6.2 (p < 0.05). There was no radiographic evidence of gross polyethylene wear, progressive radiolucencies, osteolytic lesions, acetabular fracture, or component subsidence. From these results, we can recommend the continued use of this material for acetabular components in primary THA and that further review of the current multicentre population is warranted to determine the long-term durability of the acetabular composite.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Tantalum , Acetabulum/diagnostic imaging , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Longitudinal Studies , Male , Middle Aged , Polyethylene , Prospective Studies , Prosthesis Design , Prosthesis Failure , Radiography
2.
J Bone Joint Surg Br ; 88(3): 304-9, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16498001

ABSTRACT

Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component and the acetabular host bed which ranged from 1 to 5 mm. All patients were followed up clinically and radiologically for a mean of 7.3 years (7 to 7.5). The 25 hips with the 1 to 5 mm gaps were studied for component migration at two years using the Einzel-Bild-Roentgen-Analyse (EBRA) digital measurement method. At 24 weeks all the post-operative gaps were filled with bone and no acetabular component had migrated. The radiographic outcome of all 86 components showed no radiolucent lines and no evidence of lysis. No acetabular implant was revised. There were no dislocations or other complications. The bridging of the interface gaps (up to 5 mm) by the trabecular metal monoblock acetabular component indicates the strong osteoconductive, and possibly osteoinductive, properties of trabecular metal.


Subject(s)
Acetabulum/diagnostic imaging , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Tantalum , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Biocompatible Materials , Equipment Design , Female , Hip Joint/diagnostic imaging , Humans , Male , Middle Aged , Osteoarthritis, Hip/surgery , Postoperative Period , Prosthesis Failure , Radiography , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...