Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Plant Sci ; 12(1): e11567, 2024.
Article in English | MEDLINE | ID: mdl-38369982

ABSTRACT

Premise: Most studies of the movement of orchid fruits and roots during plant development have focused on morphological observations; however, further genetic analysis is required to understand the molecular mechanisms underlying this phenomenon. A precise tool is required to observe these movements and harvest tissue at the correct position and time for transcriptomics research. Methods: We utilized three-dimensional (3D) micro-computed tomography (CT) scans to capture the movement of fast-growing Erycina pusilla roots, and built an integrated bioinformatics pipeline to process 3D images into 3D time-lapse videos. To record the movement of slowly developing E. pusilla and Phalaenopsis equestris fruits, two-dimensional (2D) photographs were used. Results: The E. pusilla roots twisted and resupinated multiple times from early development. The first period occurred in the early developmental stage (77-84 days after germination [DAG]) and the subsequent period occurred later in development (140-154 DAG). While E. pusilla fruits twisted 45° from 56-63 days after pollination (DAP), the fruits of P. equestris only began to resupinate a week before dehiscence (133 DAP) and ended a week after dehiscence (161 DAP). Discussion: Our methods revealed that each orchid root and fruit had an independent direction and degree of torsion from the initial to the final position. Our innovative approaches produced detailed spatial and temporal information on the resupination of roots and fruits during orchid development.

2.
Sci Rep ; 11(1): 11024, 2021 05 26.
Article in English | MEDLINE | ID: mdl-34040035

ABSTRACT

Dendrochronology is an essential tool to determine the date and provenance of wood from historical art objects. As standard methods to access the tree rings are invasive, X-ray computed tomography (CT) has been proposed for non-invasive dendrochronological investigation. While traditional CT can provide clear images of the inner structure of wooden objects, it requires their full rotation, imposing strong limitations on the size of the object. These limitations have previously encouraged investigations into alternative acquisition trajectories, including trajectories with only linear movement. In this paper, we use such a line-trajectory (LT) X-ray tomography technique to retrieve tree-ring patterns from large wooden objects. We demonstrate that by moving a wooden artifact sideways between the static X-ray source and the detector during acquisition, sharp reconstruction images of the tree rings can be produced. We validate this technique using computer simulations and two wooden test planks, and demonstrate it on a large iconic chest from the Rijksmuseum collection (Amsterdam, The Netherlands). The LT scanning method can be easily implemented in standard X-ray imaging units available at museum research facilities. Therefore, this scanning technique represents a major step towards the standard implementation of non-invasive dendrochronology on large wooden cultural heritage objects.

3.
Opt Express ; 26(22): 28982-28995, 2018 Oct 29.
Article in English | MEDLINE | ID: mdl-30470067

ABSTRACT

We propose a combination of an experimental approach and a reconstruction technique that leads to reduction of artefacts in X-ray computer tomography of strongly attenuating objects. Through fully automatic data alignment, data generated in multiple experiments with varying object orientations are combined. Simulations and experiments show that the solutions computed using algebraic methods based on multiple acquisitions can achieve a dramatic improvement in the reconstruction quality, even when each acquisition generates a reduced number of projections. The approach does not require any advanced setup components making it ideal for laboratory-based X-ray tomography.

4.
Opt Express ; 21(10): 12185-96, 2013 May 20.
Article in English | MEDLINE | ID: mdl-23736439

ABSTRACT

The reconstruction problem in in-line X-ray Phase-Contrast Tomography is usually approached by solving two independent linearized sub-problems: phase retrieval and tomographic reconstruction. Both problems are often ill-posed and require the use of regularization techniques that lead to artifacts in the reconstructed image. We present a novel reconstruction approach that solves two coupled linear problems algebraically. Our approach is based on the assumption that the frequency space of the tomogram can be divided into bands that are accurately recovered and bands that are undefined by the observations. This results in an underdetermined linear system of equations. We investigate how this system can be solved using three different algebraic reconstruction algorithms based on Total Variation minimization. These algorithms are compared using both simulated and experimental data. Our results demonstrate that in many cases the proposed algebraic algorithms yield a significantly improved accuracy over the conventional L2-regularized closed-form solution. This work demonstrates that algebraic algorithms may become an important tool in applications where the acquisition time and the delivered radiation dose must be minimized.


Subject(s)
Algorithms , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Reproducibility of Results , Sensitivity and Specificity
5.
Opt Express ; 21(1): 710-23, 2013 Jan 14.
Article in English | MEDLINE | ID: mdl-23388964

ABSTRACT

State-of-the-art techniques for phase retrieval in propagation based X-ray phase-contrast imaging are aiming to solve an underdetermined linear system of equations. They commonly employ Tikhonov regularization - an L2-norm regularized deconvolution scheme - despite some of its limitations. We present a novel approach to phase retrieval based on Total Variation (TV) minimization. We incorporated TV minimization for deconvolution in phase retrieval using a variety of the most common linear phase-contrast models. The results of our TV minimization was compared with Tikhonov regularized deconvolution on simulated as well as experimental data. The presented method was shown to deliver improved accuracy in reconstructions based on a single distance as well as multiple distance phase-contrast images corrupted by noise and hampered by errors due to nonlinear imaging effects.

6.
Med Phys ; 38(9): 5136-45, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21978059

ABSTRACT

PURPOSE: The implementation of in-line x-ray phase contrast imaging (PCI) for soft-tissue patient imaging is hampered by the lack of a bright and spatially coherent x-ray source that fits into the hospital environment. This article provides a quantitative characterization of the phase-contrast enhancement of a PCI system based on the miniature synchrotron technology MIRRORCLE-6X. METHODS: The phase-contrast effect was measured using an edge response of a plexiglass plate as a function of the incident angle of radiation. We have developed a comprehensive x-ray propagation model based on the system's components, properties, and geometry in order to interpret the measurement data. Monte-Carlo simulations are used to estimate the system's spectral properties and resolution. RESULTS: The measured ratio of the detected phase-contrast to the absorption contrast is currently in the range 100% to 200%. Experiments show that with the current implementation of the MIRRORCLE-6X, a target smaller than 30-40 µm does not lead to a larger phase-contrast. The reason for this is that the fraction of x-rays produced by the material (carbon filament and glue) that is used for mounting the target in the electron beam is more than 25% of the total amount of x-rays produced. This increases the apparent source size. The measured phase-contrast is at maximum two times larger than the absorption contrast with the current set-up. CONCLUSIONS: Calculations based on our model of the present imaging system predict that the phase-contrast can be up to an order of magnitude larger than the absorption contrast in case the materials used for mounting the target in the electron beam do not (or hardly) produce x-rays. The methods described in this paper provide vital feedback for guiding future modifications to the design of the x-ray target of MIRRORCLE-type system and configuration of the in-line PCI systems in general.


Subject(s)
Miniaturization/instrumentation , Synchrotrons , Tomography, X-Ray Computed/instrumentation , Electrons , Image Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...