1.
Ann Vasc Surg ; 84: 336-343, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35257909

ABSTRACT

BACKGROUND: A chronic exposure to low dose radiation, as encountered in endovascular procedures, may impact the health of surgeons and radiologists over a timespan of several months to a lifetime. This study evaluates the feasibility and efficacy of a radiation absorbing sterile drape (RADPAD) to reduce operator exposure during the endovascular treatment of obstructive peripheral artery disease (PAD). METHODS: Between February 2016 and September 2017, patients with PAD who received percutaneous transluminal angioplasty, stent placement, remote endarterectomy, or a combination thereof were included in this nonrandomized study. Patients were equally divided over a study cohort (with RADPAD) and a control cohort (without RADPAD). The unshielded body dose (E) of the staff was measured via electronic dosimeters placed at a chest height of the first operator (FO), second operator (SO), and sterile nurse (SN). A virtual maximum operator (MO) dose was constructed, yielding the highest dose per fluoroscopy run for either of the operators. Simultaneously, the dose area product (DAP) and C-arm settings for each fluoroscopy run were extracted. Staff exposures of the study cohort and control cohort were compared in terms of relative exposure (E/DAP). A secondary analysis involved an analysis of the individual fluoroscopy runs using a multivariate generalized linear mixed effect model. RESULTS: In total, 49 patients were included in this study. The use of RADPAD was technically feasible. Significant reductions of relative exposure were observed when comparing the study cohort with the control cohort. The relative exposure of the FO was reduced with 66.5% (1.82 vs. 0.61 µSv/Gycm2, P < 0.001), the relative exposure of the SO with 68.3% (0.55 vs. 0.17 µSv/Gycm2, P = 0.02), and the relative exposure of the MO with 65.8% (2.06 vs. 0.71 µSv/Gycm2, P < 0.001). Dose levels of SN were too low to draw conclusions under the current sample size. The multivariate generalized linear mixed effect model showed a significant correlation between absolute exposure of the MO and the use of the RADPAD (odds: 0.51, P < 0.001). CONCLUSIONS: Usage of a radiation absorbing drape (RADPAD) during endovascular treatment of PAD results in statistically significant reduction in a relative operator dose while presenting no drawbacks. The use of these drapes is advised in future peripheral endovascular procedures.


Subject(s)
Endovascular Procedures , Occupational Exposure , Occupational Injuries , Peripheral Arterial Disease , Radiation Exposure , Radiation Injuries , Radiation Protection , Endovascular Procedures/adverse effects , Fluoroscopy , Humans , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Occupational Injuries/etiology , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/etiology , Peripheral Arterial Disease/therapy , Radiation Dosage , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Radiography, Interventional/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...