Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Investig Med ; 63(7): 856-61, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26230492

ABSTRACT

OBJECTIVE: The aim of this study was to determine if differences in coronary endothelial function are observed between asymptomatic women with type 2 diabetes mellitus (DM) and control subjects using coronary phase contrast flow velocity magnetic resonance imaging in response to cold pressor stress, an established endothelium-dependent vasodilatory stress. METHODS: Phase contrast flow velocity imaging of the right coronary artery was performed in 7 asymptomatic premenopausal women with DM and 8 healthy female participants in response to the cold pressor test at 3 T. RESULTS: There was no significant difference in percent increase in coronary flow velocity from rest to peak flow velocity between DM and control subjects (32% ± 22% vs 46% ± 17%; P = 0.11). However, percent increase in coronary flow velocity was lower in DM than in control subjects (-3% ± 14% vs 31% ± 30%; P = 0.01) during the second minute of cold pressor stress, when endothelial-mediated vasodilation should occur. CONCLUSIONS: Asymptomatic women with DM demonstrate reduced coronary flow velocity during the second minute of cold pressor stress, indicating coronary endothelial dysfunction.


Subject(s)
Coronary Vessels/physiopathology , Diabetes Mellitus, Type 2/physiopathology , Endothelium, Vascular/physiopathology , Magnetic Resonance Imaging/methods , Adult , Blood Flow Velocity , Coronary Circulation , Female , Humans
2.
J Magn Reson Imaging ; 39(6): 1477-85, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24123721

ABSTRACT

PURPOSE: To validate conventional phase-contrast MRI (PC-MRI) measurements of steady and pulsatile flows through stenotic phantoms with various degrees of narrowing at Reynolds numbers mimicking flows in the human iliac artery using stereoscopic particle image velocimetry (SPIV) as gold standard. MATERIALS AND METHODS: A series of detailed experiments are reported for validation of MR measurements of steady and pulsatile flows with SPIV and CFD on three different stenotic models with 50%, 74%, and 87% area occlusions at three sites: two diameters proximal to the stenosis, at the throat, and two diameters distal to the stenosis. RESULTS: Agreement between conventional spin-warp PC-MRI with Cartesian read-out and SPIV was demonstrated for both steady and pulsatile flows with mean Reynolds numbers of 130, 160, and 190 at the inlet by evaluating the linear regression between the two methods. The analysis revealed a correlation coefficient of > 0.99 and > 0.96 for steady and pulsatile flows, respectively. Additionally, it was found that the most accurate measures of flow by the sequence were at the throat of the stenosis (error < 5% for both steady and pulsatile mean flows). The flow rate error distal to the stenosis was primarily found to be a function of narrowing severity including dependence on proper Venc selection. CONCLUSION: SPIV and CFD provide excellent approaches to in vitro validation of new or existing PC-MRI flow measurement techniques.


Subject(s)
Hydrodynamics , Magnetic Resonance Imaging/methods , Pulsatile Flow , Rheology/methods , Blood Flow Velocity , Constriction, Pathologic , In Vitro Techniques , Magnetics , Phantoms, Imaging , Reproducibility of Results
3.
J Cardiovasc Magn Reson ; 15: 42, 2013 May 24.
Article in English | MEDLINE | ID: mdl-23706156

ABSTRACT

BACKGROUND: Dynamic contrast enhanced (DCE) cardiovascular magnetic resonance (CMR) is increasingly used to quantify microvessels and permeability in atherosclerosis. Accurate quantification depends on reliable sampling of both vessel wall (VW) uptake and contrast agent dynamic in the blood plasma (the so called arterial input function, AIF). This poses specific challenges in terms of spatial/temporal resolution and matched dynamic MR signal range, which are suboptimal in current vascular DCE-CMR protocols. In this study we describe a novel dual-imaging approach, which allows acquiring simultaneously AIF and VW images using different spatial/temporal resolution and optimizes imaging parameters for the two compartments. We refer to this new acquisition as SHILO, Simultaneous HI-/LOw-temporal (low-/hi-spatial) resolution DCE-imaging. METHODS: In SHILO, the acquisition of low spatial resolution single-shot AIF images is interleaved with segments of higher spatial resolution images of the VW. This allows sampling the AIF and VW with different spatial/temporal resolution and acquisition parameters, at independent spatial locations. We show the adequacy of this temporal sampling scheme by using numerical simulations. Following, we validate the MR signal of SHILO against a standard 2D spoiled gradient recalled echo (SPGR) acquisition with in vitro and in vivo experiments. Finally, we show feasibility of using SHILO imaging in subjects with carotid atherosclerosis. RESULTS: Our simulations confirmed the superiority of the SHILO temporal sampling scheme over conventional strategies that sample AIF and tissue curves at the same time resolution. Both the median relative errors and standard deviation of absolute parameter values were lower for the SHILO than for conventional sampling schemes. We showed equivalency of the SHILO signal and conventional 2D SPGR imaging, using both in vitro phantom experiments (R2 =0.99) and in vivo acquisitions (R2 =0.95). Finally, we showed feasibility of using the newly developed SHILO sequence to acquire DCE-CMR data in subjects with carotid atherosclerosis to calculate plaque perfusion indices. CONCLUSIONS: We successfully demonstrate the feasibility of using the newly developed SHILO dual-imaging technique for simultaneous AIF and VW imaging in DCE-CMR of atherosclerosis. Our initial results are promising and warrant further investigation of this technique in wider studies measuring kinetic parameters of plaque neovascularization with validation against gold standard techniques.


Subject(s)
Carotid Artery Diseases/diagnosis , Magnetic Resonance Angiography/methods , Neovascularization, Pathologic/diagnosis , Carotid Artery Diseases/pathology , Contrast Media , Feasibility Studies , Gadolinium DTPA , Humans , Least-Squares Analysis , Neovascularization, Pathologic/pathology , Phantoms, Imaging , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...