Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Brachial Plex Peripher Nerve Inj ; 16(1): e31-e36, 2021 Jan.
Article in English | MEDLINE | ID: mdl-34335868

ABSTRACT

Background The suprascapular notch (SN) represents the point along the route of the suprascapular nerve (SSN) with the greatest potential risk for injury and compression. Thus, factors reducing the area of the notch have been postulated for suprascapular neuropathy development. Methods Thirty-one fresh-frozen shoulders were dissected. The contents of the SN were described according to four types as classified by Polguj et al and the middle-transverse diameter of the notch was measured. Also, the presence of an ossified superior transverse scapular ligament (STSL) was identified. Results The ligament was partially ossified in 8 specimens (25.8%), fully ossified in 6 (19.35%), and not ossified in the remaining 17 (54.85%). The mean middle-transverse diameter of the SN was 9.06 mm (standard deviation [SD] = 3.45). The corresponding for type-I notches was 8.64 mm (SD = 3.34), 8.86 mm (SD = 3.12) was for type-II, and 14.5 mm (SD = 1.02) was for type III. Middle-transverse diameter was shorter when an ossified ligament was present (mean = 5.10 mm, SD = 0.88 mm), comparing with a partially ossified ligament (mean =7.67 mm, SD = 2.24 mm) and a nonossified one (mean = 11.12 mm, SD = 2.92 mm). No statistically significant evidence was found that the middle-transverse diameter depends on the number of the elements, passing below the STSL. Conclusion Our results suggest that SSN compression could be more likely to occur when both suprascapular vessels pass through the notch. Compression of the nerve may also occur when an ossified transverse scapular ligament is present, resulting to significant reduction of the notch's area.

2.
Expert Rev Med Devices ; 5(5): 567-72, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18803467

ABSTRACT

The AO Hook plate has been used for stabilization of acromioclavicular joint dislocations. We present our experience of this newly introduced device in a general hospital, since there are not many papers in the literature reporting on this. A total of 16 patients were treated with the AO Hook plate between November 2001 and November 2003 at Princess Alexandra Hospital in Harlow, UK. For functional assessment 6 months after removal of the plate, the constant score and the pain visual analogue score were used. The pain visual analogue score ranged from 0 to 6 (mean: 0.87) and the constant score ranged from 78 to 100 (mean: 96.4). In one instance, a patient developed instability after removal of the plate. The use of this device results in excellent functional outcome for the treatment of acromioclavicular joint dislocations.


Subject(s)
Acromioclavicular Joint/surgery , Bone Plates , Joint Dislocations/surgery , Acromioclavicular Joint/diagnostic imaging , Adult , Bone Plates/adverse effects , Humans , Joint Dislocations/diagnostic imaging , Male , Middle Aged , Postoperative Complications , Radiography
3.
Clin Orthop Relat Res ; 442: 115-20, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16394749

ABSTRACT

UNLABELLED: Proximal humeral fractures, especially in elderly patients, remain a challenging problem for the surgeon because the complication rate for these fractures still remains high. The internal locked system (PHILOS) plate is a new device used for proximal humerus fracture fixation is designed to decrease the high complication rate. We prospectively evaluated our early experience using this system. Twenty patients with fractures of the proximal humerus were treated with a PHILOS plate from September 2001 to January 2004 at Princess Alexandra Hospital in Harlow, UK. Functional assessment was done using the Constant shoulder score. Two patients who had brachial plexus injury were evaluated only with the visual analogue score because we thought that the Constant objective assessment would be unreliable. Complications were monitored. The mean Constant score was found to be 76.1% (range, 30-100%). The preliminary results seem to be satisfactory. According to our experience, the plate design provides stable fixation with a good functional outcome and eliminates most hardware problems such as failure and impingement syndrome. The PHILOS plate is suitable for the majority of fractures providing that the correct surgical technique is used. LEVEL OF EVIDENCE: Therapeutic study, level IV (case series). See the Guidelines for Authors for a complete description of levels of evidence.


Subject(s)
Bone Plates , Fracture Fixation, Internal/methods , Shoulder Fractures/surgery , Adult , Aged , Aged, 80 and over , Bone Screws , Female , Humans , Male , Middle Aged , Prospective Studies , Radiography , Range of Motion, Articular , Shoulder Dislocation/diagnostic imaging , Shoulder Dislocation/surgery , Shoulder Fractures/diagnostic imaging , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...