1.
Eur Radiol ; 25(2): 410-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25218763

ABSTRACT

PURPOSE: To demonstrate the use of a new 3D diagnostic imaging technology, termed Multimodal Ultrasonic Tomography (MUT), for the detection of solid breast lesions < 15 mm in maximum dimension. METHODS AND MATERIALS: 3D MUT imaging was performed on 71 volunteers presenting BIRADS-4 nodules, asymmetrical densities, and architectural distortions in X-ray mammograms, who subsequently underwent biopsy. MUT involved D tomographic imaging of the pendulant breast in a water bath using transmission ultrasound and constructed multimodal images corresponding to refractivity and frequency-dependent attenuation (calibrated relative to water). The multimodal images were fused into composite images and a composite index (CI) was calculated and used for diagnostic purposes. The composite images were evaluated against results of histopathology on biopsy specimens. RESULTS: Histopathology revealed 22 malignant and 49 benign lesions. The pixels of 22 malignant lesions exhibited high values in both refractivity and attenuation, resulting in CI values > 1. In contrast, 99.9% of benign lesions and normal tissue pixels exhibited lower values of at least one of the attributes measured, corresponding to CI values < 1. CONCLUSIONS: MUT imaging appears to differentiate small malignant solid breast lesions as exhibiting CI values >1, while benign lesions or normal breast tissues exhibit CI values <1. KEY POINTS: • MUT was able to detect all 22 biopsy-confirmed malignant lesions. • MUT was able to differentiate the malignant from the benign lesions. • Additional MUT detections outside the biopsy area must be evaluated prospectively.


Subject(s)
Breast Neoplasms/diagnostic imaging , Imaging, Three-Dimensional , Multimodal Imaging/methods , Neoplasm Staging/methods , Ultrasonography, Mammary/methods , Biopsy , Breast Neoplasms/pathology , Diagnosis, Differential , Female , Humans , Reproducibility of Results , Retrospective Studies
2.
Eur Radiol ; 23(3): 673-83, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22983317

ABSTRACT

OBJECTIVES: To introduce a new three-dimensional (3D) diagnostic imaging technology, termed "multimodal ultrasonic tomography" (MUT), for the detection of breast cancer without ionising radiation or compression. METHODS: MUT performs 3D tomography of the pendulant breast in a water-bath using transmission ultrasound in a fixed-coordinate system. Specialised electronic hardware and signal processing algorithms are used to construct multimodal images for each coronal slice, corresponding to measurements of refractivity and frequency-dependent attenuation and dispersion. In-plane pixel size is 0.25 mm × 0.25 mm and the inter-slice interval can vary from 1 to 4 mm, depending on clinical requirements. MUT imaging was performed on 25 patients ("off-label" use for research purposes only), presenting lesions with sizes >10 mm. Histopathology of biopsy samples, obtained from all patients, were used to evaluate the MUT outcomes. RESULTS: All lesions (21 malignant and four benign) were clearly identified on the MUT images and correctly classified into benign and malignant based on their respective multimodal information. Malignant lesions generally exhibited higher values of refractivity and frequency-dependent attenuation and dispersion. CONCLUSION: Initial clinical results confirmed the ability of MUT to detect and differentiate all suspicious lesions with sizes >10 mm discernible in mammograms of 25 female patients.


Subject(s)
Algorithms , Breast Neoplasms/diagnostic imaging , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Subtraction Technique , Ultrasonography, Mammary/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Reproducibility of Results , Sensitivity and Specificity
5.
Acta Radiol ; 49(3): 267-70, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18365811

ABSTRACT

BACKGROUND: A matter of substantial concern regarding all needle biopsy techniques is seeding along the biopsy needle tract. PURPOSE: To assess cell seeding along the needle tract of vacuum-assisted breast biopsy (VABB). MATERIAL AND METHODS: The study included 21 patients with ductal carcinoma in situ (DCIS) and 10 patients with invasive ductal carcinoma (IDC) diagnosed by VABB for nonpalpable mammographic lesions. VABB (11G, on a Fischer table) was performed, and the duration of the procedure was measured. After surgery, the whole needle tract was embedded in paraffin blocks, stained with hematoxylin-eosin, and examined by a pathologist. RESULTS: Cases with dissemination of cancer cells in the needle tract were not observed (one-sided 97.5% CI 0-10.0%). In 2/31 (6.5%) cases (95% CI 0.8-21.4%), benign epithelial cell displacement was observed, and the duration of VABB was significantly longer in these two cases (52.5+/-3.5 min vs. 42.0+/-4.4 min for cases without benign cell displacement; P = 0.018, Mann-Whitney-Wilcoxon test for independent samples). CONCLUSION: No displacement of malignant cells within the 11G needle tract was documented. Benign cell displacement was associated with longer VABB duration. The phenomenon of tumor cell dissemination along the needle tract is of questionable clinical significance when the treatment guidelines are followed.


Subject(s)
Biopsy, Needle/adverse effects , Breast Neoplasms/pathology , Breast/pathology , Carcinoma, Ductal, Breast/pathology , Carcinoma, Intraductal, Noninfiltrating/pathology , Neoplasm Seeding , Biopsy, Needle/instrumentation , Biopsy, Needle/methods , Breast/surgery , Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/radiotherapy , Carcinoma, Ductal, Breast/surgery , Carcinoma, Intraductal, Noninfiltrating/radiotherapy , Carcinoma, Intraductal, Noninfiltrating/surgery , Female , Guideline Adherence , Humans , Mastectomy , Time Factors , Vacuum
7.
Acta Radiol ; 49(7): 752-4, 2008 Sep.
Article in English | MEDLINE | ID: mdl-19143060

ABSTRACT

A 42-year-old woman underwent vacuum-assisted breast biopsy (VABB, 11G) due to a nonpalpable, BI-RADS 4A lesion without microcalcifications. During the procedure, an extraordinarily large amount of blood was lost. In an attempt to stop the hemorrhage and limit the imminent hematoma, a thin intravascular Fogarty catheter was inserted adjacent to the VABB probe (through the same incision). The catheter was maintained in its position for 2 days. At clinical examination 9 days after VABB, no hematoma was present. The use of a Fogarty catheter seems capable of limiting any severe bleeding after VABB and may also possibly prevent subsequent hematoma formation.


Subject(s)
Biopsy/methods , Breast Diseases/pathology , Catheterization/instrumentation , Hematoma/prevention & control , Hemorrhage/prevention & control , Adult , Biopsy/adverse effects , Diagnosis, Differential , Female , Hematoma/etiology , Hemorrhage/etiology , Humans , Vacuum
8.
Cardiovasc Intervent Radiol ; 19(3): 187-9, 1996.
Article in English | MEDLINE | ID: mdl-8661648

ABSTRACT

Two patients with cardiac involvement of hydatid disease are presented: one with hydatid cyst of the interventricular septum and pulmonary arteries and the other with multiple pulmonary cysts associated with intracardiac and pericardial cysts. The ability of magnetic resonance imaging (MRI) to provide a global view of cardiac anatomy in any plane with high contrast between flowing blood and soft tissue ensures it an important role in the diagnosis and preoperative assessment of hydatid disease of the heart.


Subject(s)
Cardiomyopathies/parasitology , Echinococcosis/diagnosis , Aged , Cardiomyopathies/diagnosis , Echinococcosis, Pulmonary/diagnosis , Female , Humans , Magnetic Resonance Imaging , Middle Aged , Myocardium/pathology , Tomography, X-Ray Computed