1.
Technol Cancer Res Treat ; 10(3): 231-42, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21517129

ABSTRACT

In order to apply highly conformal dose distributions, which are characterized by steep dose fall-offs, it is necessary to know the exact target location and extension. This study aims at evaluating the impact of using combined CT-MRI images in organ delineation compared to using CT images alone, on the clinical results. For 10 prostate cancer patients, the respective CT and MRI images at treatment position were acquired. The CTV was delineated using the CT and MRI images, separately, whereas bladder and rectum were delineated using the CT images alone. Based on the CT and MRI images, two CTVs were produced for each patient. The mutual information algorithm was used in the fusion of the two image sets. In this way, the structures drawn on the MRI images were transferred to the CT images in order to produce the treatment plans. For each set of structures of each patient, IMRT and 3D-CRT treatment plans were produced. The individual treatment plans were compared using the biologically effective uniform dose () and the complication-free tumor control probability (P(+)) concepts together with the DVHs of the targets and organs at risk and common dosimetric criteria. For the IMRT treatment, at the optimum dose level of the average CT and CT-MRI delineated CTV dose distributions, the P(+) values are 74.7% in both cases for a of 91.5 Gy and 92.1 Gy, respectively. The respective average total control probabilities, PB are 90.0% and 90.2%, whereas the corresponding average total complication probabilities, P(I) are 15.3% and 15.4%. Similarly, for the 3D-CRT treatment, the average P(+) values are 42.5% and 46.7%, respectively for a of 86.4 Gy and 86.7 Gy, respectively. The respective average P(B) values are 80.0% and 80.6%, whereas the corresponding average P(I) values are 37.4% and 33.8%, respectively. For both radiation modalities, the improvement mainly stems from the better sparing of rectum. According to these results, the expected clinical effectiveness of IMRT can be increased by a maximum ΔP(+) of around 0.9%, whereas of 3D-CRT by about 4.2% when combined CT-MRI delineation is performed instead of using CT images alone. It is apparent that in both IMRT and 3D-CRT radiation modalities, the better knowledge of the CTV extension improved the produced dose distribution. It is shown that the CTV is irradiated more effectively, while the complication probabilities of bladder and rectum, which is the principal organs at risk, are lower in the CT-MRI based treatment plans.


Subject(s)
Adenocarcinoma/diagnosis , Adenocarcinoma/radiotherapy , Magnetic Resonance Imaging , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Adenocarcinoma/diagnostic imaging , Dose-Response Relationship, Radiation , Humans , Male , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Radiometry , Radiotherapy Dosage , Radiotherapy, Conformal , Rectum/diagnostic imaging , Urinary Bladder/diagnostic imaging
2.
Med Phys ; 25(10): 1975-84, 1998 Oct.
Article in English | MEDLINE | ID: mdl-9800706

ABSTRACT

An analytical Monte Carlo simulation code has been used to perform dosimetry calculations around an 192Ir high dose-rate brachytherapy source utilized in the widely used microSelectron afterloaded system. Radial dose functions, dose rate constant and anisotropy functions, utilized in the AAPM Task Group 43 dose estimation formalism, have been calculated. In addition, measurements of anisotropy functions using LiF TLD-100 rods have been performed in a polystyrene phantom to support our Monte Carlo calculations. The energy dependence of LiF TLD response was investigated over the whole range of measurement distances and angles. TLD measurements and Monte Carlo calculations are in agreement to each other and agree with published data. The influence of phantom dimensions on calculations was also investigated. Radial dose functions were found to depend significantly on phantom dimensions at radial distances near phantom edges. Deviations of up to 25% are observed at these distances due to the lack of full scattering conditions, indicating that body dimensions should be taken into account in treatment planning when the absorbed dose is calculated near body edges. On the other hand, anisotropy functions do not demonstrate a strong dependence on phantom dimensions. However, these functions depend on radial distance at angles close to the longitudinal axis of the source, where deviations of up to 20% are observed.


Subject(s)
Brachytherapy/statistics & numerical data , Iridium Radioisotopes/therapeutic use , Monte Carlo Method , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Thermoluminescent Dosimetry/statistics & numerical data , Anisotropy , Biophysical Phenomena , Biophysics , Humans , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...