J Acoust Soc Am ; 109(6): 3055-64, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11425148

ABSTRACT

The effect of array geometry on the steering performance of ultrasound phased arrays is examined theoretically, in order to maximize array performance under the given anatomical constraints. This paper evaluates the performance of arrays with spherical and cylindrical geometry, determined by using computer simulations of the pressure fields produced at various extremes of steering. The spherical segment arrays were truncated for insertion into the rectum, and contained either annular or linear elements. The cylindrical arrays were either flat or had a variable curvature applied along their length. Fields were computed by dividing the array elements into many point sources. The effectiveness of an array configuration when steered to a particular focal location was assessed by defining a parameter, G, as the ratio of the intensity at the desired focus to the maximum intensity of any unwanted lobes. The performance of truncated spherical arrays with annular elements was evaluated for focal steering along the array axis (in depth, in the z direction). When steered 15 mm toward the source, these truncated spherical annular arrays exhibited excellent performance, with G>5.7 for arrays containing more than 10 elements. Similarly, the spherical arrays with linear elements performed well when steered along the array axis to the same degree, with G>7 (for element widths up to 3 lambda), though many more array elements were required. However, when these arrays were steered 15 mm laterally, along the length of the prostate (the y direction), the value for G fell below 1 for element widths greater than about 1.6 lambda. It was found that the cylindrical arrays performed much better for y-direction steering (G>4, for 60 mm arrays with an element width of 1.75 lambda), but their performance was poorer when steered in the z direction (G approximately 4 for an element width of 1.5 lambda). In order to find a compromise between these extremes, a curved cylindrical array was examined, which was a cylindrical array with additional curvature along its length. These curved cylindrical arrays yielded performance between that of spherical linear arrays and cylindrical arrays, with better steering along the y direction than the spherical arrays and better z-direction steering than the cylindrical arrays.


Subject(s)
Models, Biological , Prostatic Diseases/therapy , Prostatic Neoplasms/therapy , Ultrasonic Therapy/methods , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...