Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Pacing Clin Electrophysiol ; 43(3): 269-277, 2020 03.
Article in English | MEDLINE | ID: mdl-31868241

ABSTRACT

BACKGROUND: Cryoballoon apposition is crucial for durable pulmonary vein isolation (PVI) in atrial fibrillation, yet the balloon is difficult to visualize by conventional mapping systems, and pulmonary venography may miss small or out-of-plane leaks. We report a novel imaging system that offers real-time 3D navigation of the cryoballoon within atrial anatomy that may circumvent these issues. METHODS AND RESULTS: A novel overlay guidance system (OGS) registers already-acquired segmented atrial cardiac tomography (CT) with fluoroscopy, enabling real-time visualization of the cryoballoon within tomographic left atrial imaging during PVI. Phantom experiments in a patient-specific 3D printed left atrium showed feasibility for confirming PV apposition and leaks. We applied OGS prospectively to 68 PVs during PVI in 17 patients. The cryoballoon was successfully reconstructed in all cases, and its apposition was compared to concurrent PV venography. The OGS uncovered leaks undetected by venography in nine veins (eight cases), which enabled repositioning, confirming apposition in remaining 68 veins. Concordance of OGS to venography was 83.8% (χ2 , P < .01) CONCLUSIONS: We report a new system for real-time imaging of cryoballoon catheters to ensure PV apposition within the tomography of the left atrium. While providing high concordance with other imaging modalities for confirming balloon apposition or leak, the system also identified leaks missed by venography. Future studies should determine if this tool can provide a new reference for cryoballoon positioning.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cryosurgery/methods , Imaging, Three-Dimensional , Pulmonary Veins/surgery , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods , Aged , Cryosurgery/instrumentation , Feasibility Studies , Female , Humans , Male , Phantoms, Imaging , Phlebography
2.
Circ Arrhythm Electrophysiol ; 11(6): e005846, 2018 06.
Article in English | MEDLINE | ID: mdl-29884620

ABSTRACT

BACKGROUND: Mechanisms for persistent atrial fibrillation (AF) are unclear. We hypothesized that putative AF drivers and disorganized zones may interact dynamically over short time scales. We studied this interaction over prolonged durations, focusing on regions where ablation terminates persistent AF using 2 mapping methods. METHODS: We recruited 55 patients with persistent AF in whom ablation terminated AF prior to pulmonary vein isolation from a multicenter registry. AF was mapped globally using electrograms for 360±45 cycles using (1) a published phase method and (2) a commercial activation/phase method. RESULTS: Patients were 62.2±9.7 years, 76% male. Sites of AF termination showed rotational/focal patterns by methods 1 and 2 (51/55 vs 55/55; P=0.13) in spatially conserved regions, yet fluctuated over time. Time points with no AF driver showed competing drivers elsewhere or disordered waves. Organized regions were detected for 61.6±23.9% and 70.6±20.6% of 1 minute per method (P=nonsignificant), confirmed by automatic phase tracking (P<0.05). To detect AF drivers with >90% sensitivity, 8 to 32 s of AF recordings were required depending on driver definition. CONCLUSIONS: Sites at which persistent AF terminated by ablation show organized activation that fluctuate over time, because of collision from concurrent organized zones or fibrillatory waves, yet recur in conserved spatial regions. Results were similar by 2 mapping methods. This network of competing mechanisms should be reconciled with existing disorganized or driver mechanisms for AF, to improve clinical mapping and ablation of persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02997254.


Subject(s)
Action Potentials , Atrial Fibrillation/surgery , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Conduction System/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Germany , Heart Conduction System/physiopathology , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Registries , Time Factors , Treatment Outcome , United States
3.
Circ Arrhythm Electrophysiol ; 11(5): e006119, 2018 05.
Article in English | MEDLINE | ID: mdl-29743170

ABSTRACT

BACKGROUND: The outcomes from pulmonary vein isolation (PVI) for atrial fibrillation (AF) are suboptimal, but the benefits of additional lesion sets remain unproven. Recent studies propose ablation of AF drivers improves outcomes over PVI, yet with conflicting reports in the literature. We undertook a systematic literature review and meta-analysis to determine outcomes from ablation of AF drivers in addition to PVI or as a stand-alone procedure. METHODS: Database search was done using the terms atrial fibrillation and ablation or catheter ablation and driver or rotor or focal impulse or FIRM (Focal Impulse and Rotor Modulation). We pooled data using random effects model and assessed heterogeneity with I2 statistic. RESULTS: Seventeen studies met inclusion criteria, in a cohort size of 3294 patients. Adding AF driver ablation to PVI reported freedom from AF of 72.5% (confidence interval [CI], 62.1%-81.8%; P<0.01) and from all arrhythmias of 57.8% (CI, 47.5%-67.7%; P<0.01). AF driver ablation when added to PVI or as stand-alone procedure compared with controls produced an odds ratio of 3.1 (CI, 1.3-7.7; P=0.02) for freedom from AF and an odds ratio of 1.8 (CI, 1.2-2.7; P<0.01) for freedom from all arrhythmias in 4 controlled studies. AF termination rate was 40.5% (CI, 30.6%-50.9%) and predicted favorable outcome from ablation(P<0.05). CONCLUSIONS: In controlled studies, the addition of AF driver ablation to PVI supports the possible benefit of a combined approach of AF driver ablation and PVI in improving single-procedure freedom from all arrhythmias. However, most studies are uncontrolled and are limited by substantial heterogeneity in outcomes. Large multicenter randomized trials are needed to precisely define the benefits of adding driver ablation to PVI.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/surgery , Action Potentials , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Female , Heart Rate , Humans , Male , Middle Aged , Progression-Free Survival , Pulmonary Veins/physiopathology , Recurrence , Risk Factors , Time Factors , Treatment Outcome
4.
Circ Arrhythm Electrophysiol ; 11(1): e005258, 2018 01.
Article in English | MEDLINE | ID: mdl-29330332

ABSTRACT

BACKGROUND: The mechanisms by which persistent atrial fibrillation (AF) terminates via localized ablation are not well understood. To address the hypothesis that sites where localized ablation terminates persistent AF have characteristics identifiable with activation mapping during AF, we systematically examined activation patterns acquired only in cases of unequivocal termination by ablation. METHODS AND RESULTS: We recruited 57 patients with persistent AF undergoing ablation, in whom localized ablation terminated AF to sinus rhythm or organized tachycardia. For each site, we performed an offline analysis of unprocessed unipolar electrograms collected during AF from multipolar basket catheters using the maximum -dV/dt assignment to construct isochronal activation maps for multiple cycles. Additional computational modeling and phase analysis were used to study mechanisms of map variability. At all sites of AF termination, localized repetitive activation patterns were observed. Partial rotational circuits were observed in 26 of 57 (46%) cases, focal patterns in 19 of 57 (33%), and complete rotational activity in 12 of 57 (21%) cases. In computer simulations, incomplete segments of partial rotations coincided with areas of slow conduction characterized by complex, multicomponent electrograms, and variations in assigning activation times at such sites substantially altered mapped mechanisms. CONCLUSIONS: Local activation mapping at sites of termination of persistent AF showed repetitive patterns of rotational or focal activity. In computer simulations, complete rotational activation sequence was observed but was sensitive to assignment of activation timing particularly in segments of slow conduction. The observed phenomena of repetitive localized activation and the mechanism by which local ablation terminates putative AF drivers require further investigation.


Subject(s)
Atrial Fibrillation/diagnosis , Body Surface Potential Mapping/methods , Catheter Ablation/methods , Heart Conduction System/physiopathology , Heart Rate/physiology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Time Factors , Treatment Outcome
5.
Rev Port Cardiol ; 36 Suppl 1: 9-17, 2017 Nov.
Article in English, Portuguese | MEDLINE | ID: mdl-29126896

ABSTRACT

Pulmonary vein isolation (PVI) is central to ablation approaches for atrial fibrillation (AF), yet many patients still have arrhythmia recurrence after one or more procedures despite the latest technology for PVI. Ablation of rotational or focal sources for AF, which lie outside the pulmonary veins in many patients, is a practical approach that has been shown to improve success by many groups. Localized sources lie in atrial regions shown mechanistically to sustain AF in optical mapping and clinical studies of human AF, as well as computational and animal studies. Because they arise in localized atrial regions, AF sources may explain central paradoxes in clinical practice - such as how limited ablation in patient specific sites can terminate persistent AF yet extensive anatomical ablation at stereotypical locations, which should extinguish disordered waves, does not improve success in clinical trials. Ongoing studies may help to resolve many controversies in the field of rotational sources for AF. Studies now verify rotational activation by multiple mapping approaches in the same patients, at sites where ablation terminates persistent AF. However, these studies also show that certain mapping methods are less effective for detecting AF sources than others. It is also recognized that the success of AF source ablation is technique dependent. This review article provides a mechanistic and clinical rationale to ablate localized sources (rotational and focal), and describes successful techniques for their ablation as well as pitfalls to avoid. We hope that this review will serve as a platform for future improvements in the patient-tailored ablation for complex arrhythmias.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cardiac Surgical Procedures/methods , Humans
6.
Europace ; 19(5): 769-774, 2017 May 01.
Article in English | MEDLINE | ID: mdl-28339546

ABSTRACT

AIMS: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). METHODS AND RESULTS: We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). CONCLUSIONS: Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation.


Subject(s)
Atrial Fibrillation/mortality , Atrial Fibrillation/surgery , Body Surface Potential Mapping/mortality , Catheter Ablation/mortality , Catheter Ablation/statistics & numerical data , Postoperative Complications/mortality , Surgery, Computer-Assisted/mortality , Atrial Fibrillation/diagnostic imaging , Body Surface Potential Mapping/methods , Body Surface Potential Mapping/statistics & numerical data , Catheter Ablation/methods , Cohort Studies , Female , Humans , Male , Middle Aged , Postoperative Complications/prevention & control , Prevalence , Risk Factors , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/statistics & numerical data , Survival Rate , Treatment Outcome , United States/epidemiology
7.
J Cardiovasc Electrophysiol ; 28(6): 615-622, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28185348

ABSTRACT

INTRODUCTION: The mechanisms for atrial fibrillation (AF) are unclear in part because diverse mapping techniques yield diverse maps, ranging from stable organized sources to highly disordered waves. We hypothesized that AF mechanisms may be clarified if mapping techniques were compared in the same patients, and referenced to a clinical endpoint. We compared two independent AF mapping techniques in patients in whom ablation terminated persistent AF before pulmonary vein isolation (PVI). METHODS AND RESULTS: We identified 12 patients with persistent AF (61.2 ± 10.8 years, four female) in whom mapping with 64 pole baskets and technique 1 (activation/phase mapping, FIRM) identified rotational activation patterns during at least 50% of the 4-second mapping interval and targeted ablation at these rotational sites terminated AF to sinus rhythm (n = 10) or atrial tachycardia. We analyzed the unipolar electrograms of these patients to determine phase maps of activation by an independent technique 2 (Kuklik, Schotten et al., IEEE Trans Biomed Eng 2015). Compared to technique 1, technique 2 revealed a source in 12 of 12 (100%) cases with spatial concordance in all cases (P <0.05) and similar rotational characteristics. CONCLUSION: At sites where ablation terminated persistent AF, two independent mapping techniques identified stable rotational activation for multiple cycles that drove peripheral disorder. Future comparative studies referenced to a clinical endpoint may help reconcile if discrepancies between AF mapping studies reports represent techniques, patient populations or models of AF, and improve mapping to better guide ablation.


Subject(s)
Action Potentials , Atrial Fibrillation/diagnosis , Electrophysiologic Techniques, Cardiac , Heart Atria/physiopathology , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Heart Atria/surgery , Humans , Male , Middle Aged , Predictive Value of Tests , Pulmonary Veins/physiopathology , Pulmonary Veins/surgery , Signal Processing, Computer-Assisted , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...