Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
J Cardiovasc Magn Reson ; 26(1): 101032, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38431079

ABSTRACT

BACKGROUND: Identification of increased pulmonary capillary wedge pressure (PCWP) by right heart catheterization (RHC) is the reference standard for the diagnosis of heart failure with preserved ejection fraction (HFpEF). Recently, cardiovascular magnetic resonance (CMR) imaging estimation of PCWP at rest was introduced as a non-invasive alternative. Since many patients are only identified during physiological exercise-stress, we hypothesized that novel exercise-stress CMR-derived PCWP emerges superior compared to its assessment at rest. METHODS: The HFpEF-Stress Trial prospectively recruited 75 patients with exertional dyspnea and diastolic dysfunction who then underwent rest and exercise-stress RHC and CMR. HFpEF was defined according to PCWP (overt HFpEF ≥15 mmHg at rest, masked HFpEF ≥25 mmHg during exercise-stress). CMR-derived PCWP was calculated based on previously published formula using left ventricular mass and either biplane left atrial volume (LAV) or monoplane left atrial area (LAA). RESULTS: LAV (rest/stress: r = 0.50/r = 0.55, p < 0.001) and LAA PCWP (rest/stress: r = 0.50/r = 0.48, p < 0.001) correlated significantly with RHC-derived PCWP while numerically overestimating PCWP at rest and underestimating PCWP during exercise-stress. LAV and LAA PCWP showed good diagnostic accuracy to detect HFpEF (area under the receiver operating characteristic curve (AUC) LAV rest 0.73, stress 0.81; LAA rest 0.72, stress 0.77) with incremental diagnostic value for the detection of masked HFpEF using exercise-stress (AUC LAV rest 0.54 vs stress 0.67, p = 0.019, LAA rest 0.52 vs stress 0.66, p = 0.012). LAV but not LAA PCWP during exercise-stress was a predictor for 24 months hospitalization independent of a medical history for atrial fibrillation (hazard ratio (HR) 1.26, 95% confidence interval 1.02-1.55, p = 0.032). CONCLUSION: Non-invasive PCWP correlates well with the invasive reference at rest and during exercise stress. There is overall good diagnostic accuracy for HFpEF assessment using CMR-derived estimated PCWP despite deviations in absolute agreement. Non-invasive exercise derived PCWP may particularly facilitate detection of masked HFpEF in the future.

2.
Int J Cardiol ; 404: 131949, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38471649

ABSTRACT

BACKGROUND: With emerging therapies, early diagnosis of heart failure with preserved ejection fraction (HFpEF) comes to the fore. Whilst the reference standard of exercise-stress right heart catheterisation is well established, the clinical routine struggles between feasibility of exercise-stress and diagnostic accuracy of available tests. METHODS: The HFpEF Stress Trial (DZHK-17) prospectively enrolled 75 patients with exertional dyspnoea and echocardiographic signs of diastolic dysfunction (E/e' > 8) who underwent simultaneous rest and exercise-stress echocardiography and right heart catheterisation (RHC). HFpEF was defined according to pulmonary capillary wedge pressure (HFpEF: PCWP rest: ≥15 mmHg stress: ≥25 mmHg). Patients were classified as non-cardiac dyspnoea (NCD) in the absence of HFpEF and cardiovascular disease. LA compliance was defined as reservoir strain (Es)/(E/e'). Follow-up was conducted after 4 years to evaluate cardiovascular hospitalisation (CVH). RESULTS: The final study population included 68 patients (HFpEF n = 34 and NCD n = 34) of which 23 reached the clinical endpoint, 1 patient was lost to follow-up. Patients with HFpEF according to the HFA-PEFF score (≥5 points) had significantly lower LA compliance at rest (p < 0.001) compared to patients with a score ≤ 4. LA compliance at rest outperformed E/e' (AUC 0.78 vs 0.87, p = 0.024) and showed a statistical trend to outperform Es (AUC 0.79 vs 0.87, p = 0.090) for the diagnosis of HFpEF. LA compliance at rest predicted CVH (HR 2.83, 95% CI 1.70-4.74, p < 0.001) irrespective of concomitant atrial fibrillation. CONCLUSIONS: LA compliance at rest can be obtained from clinical routine imaging and bears strong diagnostic and prognostic accuracy. Addition of LA compliance can improve the role of echocardiography as the primary test and gatekeeper.


Subject(s)
Heart Failure , Noncommunicable Diseases , Humans , Heart Failure/diagnostic imaging , Heart Failure/drug therapy , Stroke Volume , Prognosis , Heart Atria , Dyspnea , Ventricular Function, Left
3.
ESC Heart Fail ; 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38480481

ABSTRACT

AIMS: This study aimed to identify the impact of increased epicardial adipose tissue (EAT) and its regional distribution on cardiac function in patients with diastolic dysfunction. METHODS AND RESULTS: Sixty-eight patients with exertional dyspnoea (New York Heart Association ≥II), preserved ejection fraction (≥50%), and diastolic dysfunction (E/e' ≥ 8) underwent rest and stress right heart catheterization, transthoracic echocardiography, and cardiovascular magnetic resonance (CMR). EAT volumes were depicted from CMR short-axis stacks. First, the impact of increased EAT above the median was investigated. Second, the association of ventricular and atrial EAT with myocardial deformation at rest and during exercise stress was analysed in a multivariable regression analysis. Patients with high EAT had higher HFA-PEFF and H2FPEFF scores as well as N-terminal prohormone of brain natriuretic peptide levels (all P < 0.048). They were diagnosed with manifest heart failure with preserved ejection fraction (HFpEF) more frequently (low EAT: 37% vs. high EAT: 64%; P = 0.029) and had signs of adverse remodelling indicated by higher T1 times (P < 0.001). No differences in biventricular volumetry and left ventricular mass (all P > 0.074) were observed. Patients with high EAT had impaired atrial strain at rest and during exercise stress, and impaired ventricular strain during exercise stress. Regionally increased EAT was independently associated with functional impairment of the adjacent chambers. CONCLUSIONS: Patients with diastolic dysfunction and increased EAT show more pronounced signs of diastolic functional failure and adverse structural remodelling. Despite similar morphological characteristics, patients with high EAT show significant cardiac functional impairment, in particular in the atria. Our results indicate that regionally increased EAT directly induces atrial functional failure, which represents a distinct pathophysiological feature in HFpEF.

4.
Clin Res Cardiol ; 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38324040

ABSTRACT

BACKGROUND: Accurate risk stratification is important to improve patient selection and outcome of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). As epicardial adipose tissue (EAT) is discussed to be involved in cardiovascular disease, it could be useful as a marker of poor prognosis in patients with severe AS undergoing TAVR. METHODS: A total of 416 patients diagnosed with severe AS by transthoracic echocardiography were assigned for TAVR and enrolled for systematic assessment. Patients underwent clinical surveys and 5-year long-term follow-up, with all-cause mortality as the primary endpoint. EAT volume was quantified on pre-TAVR planning CTs. Patients were retrospectively dichotomized at the median of 74 cm3 of EAT into groups with low EAT and high EAT volumes. Mortality rates were compared using Kaplan-Meyer plots and uni- and multivariable cox regression analyses. RESULTS: A total number of 341 of 416 patients (median age 80.9 years, 45% female) were included in the final analysis. Patients with high EAT volumes had similar short-term outcome (p = 0.794) but significantly worse long-term prognosis (p = 0.023) compared to patients with low EAT volumes. Increased EAT volumes were associated with worse long-term outcome (HR1.59; p = 0.031) independently from concomitant cardiovascular risk factors, general type of AS, and functional echocardiography parameters of AS severity (HR1.69; p = 0.013). CONCLUSION: Increased EAT volume is an independent predictor of all-cause mortality in patients with severe AS undergoing TAVR. It can be easily obtained from pre-TAVR planning CTs and may thus qualify as a novel marker to improve prognostication and management of patient with severe AS. TRIAL REGISTRATION: DRKS, DRKS00024479.

5.
Int J Cardiovasc Imaging ; 40(4): 853-862, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38236362

ABSTRACT

This methodological study aimed to validate the cardiac output (CO) measured by exercise-stress real-time phase-contrast cardiovascular magnetic resonance imaging (CMR) in patients with heart failure and preserved ejection fraction (HFpEF). 68 patients with dyspnea on exertion (NYHA ≥ II) and echocardiographic signs of diastolic dysfunction underwent rest and exercise stress right heart catheterization (RHC) and CMR within 24 h. Patients were diagnosed as overt HFpEF (pulmonary capillary wedge pressure (PCWP) ≥ 15mmHg at rest), masked HFpEF (PCWP ≥ 25mmHg during exercise stress but < 15mmHg at rest) and non-cardiac dyspnea. CO was calculated using RHC as the reference standard, and in CMR by the volumetric stroke volume, conventional phase-contrast and rest and stress real-time phase-contrast imaging. At rest, the CMR based CO showed good agreement with RHC with an ICC of 0.772 for conventional phase-contrast, and 0.872 for real-time phase-contrast measurements. During exercise stress, the agreement of real-time CMR and RHC was good with an ICC of 0.805. Real-time measurements underestimated the CO at rest (Bias:0.71 L/min) and during exercise stress (Bias:1.4 L/min). Patients with overt HFpEF had a significantly lower cardiac index compared to patients with masked HFpEF and with non-cardiac dyspnea during exercise stress, but not at rest. Real-time phase-contrast CO can be assessed with good agreement with the invasive reference standard at rest and during exercise stress. While moderate underestimation of the CO needs to be considered with non-invasive testing, the CO using real-time CMR provides useful clinical information and could help to avoid unnecessary invasive procedures in HFpEF patients.


Subject(s)
Cardiac Output , Exercise Test , Heart Failure , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left , Humans , Female , Male , Heart Failure/physiopathology , Heart Failure/diagnostic imaging , Aged , Middle Aged , Reproducibility of Results , Cardiac Catheterization , Magnetic Resonance Imaging, Cine , Time Factors , Dyspnea/physiopathology , Dyspnea/etiology , Dyspnea/diagnostic imaging , Ventricular Function, Right
6.
Sci Rep ; 14(1): 634, 2024 01 05.
Article in English | MEDLINE | ID: mdl-38182625

ABSTRACT

Cardiovascular magnetic resonance (CMR)-derived hemodynamic force (HDF) analyses have been introduced recently enabling more in-depth cardiac function evaluation. Inter-study reproducibility is important for a widespread clinical use but has not been quantified for this novel CMR post-processing tool yet. Serial CMR imaging was performed in 11 healthy participants in a median interval of 63 days (range 49-87). HDF assessment included left ventricular (LV) longitudinal, systolic peak and impulse, systolic/diastolic transition, diastolic deceleration as well as atrial thrust acceleration forces. Inter-study reproducibility and study sample sizes required to demonstrate 10%, 15% or 20% relative changes of HDF measurements were calculated. In addition, intra- and inter-observer analyses were performed. Intra- and inter-observer reproducibility was excellent for all HDF parameters according to intraclass correlation coefficient (ICC) values (> 0.80 for all). Inter-study reproducibility of all HDF parameters was excellent (ICC ≥ 0.80 for all) with systolic parameters showing lower coeffients of variation (CoV) than diastolic measurements (CoV 15.2% for systolic impulse vs. CoV 30.9% for atrial thrust). Calculated sample sizes to detect relative changes ranged from n = 12 for the detection of a 20% relative change in systolic impulse to n = 200 for the detection of 10% relative change in atrial thrust. Overall inter-study reproducibility of CMR-derived HDF assessments was sufficient with systolic HDF measurements showing lower inter-study variation than diastolic HDF analyses.


Subject(s)
Hemodynamics , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Heart Atria , Magnetic Resonance Spectroscopy
7.
Int J Cardiol ; 396: 131563, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37926379

ABSTRACT

BACKGROUND: Myocardial deformation assessment by cardiovascular magnetic resonance-feature tracking (CMR-FT) has incremental prognostic value over volumetric analyses. Recently, atrial functional analyses have come to the fore. However, to date recommendations for optimal resolution parameters for accurate atrial functional analyses are still lacking. METHODS: CMR-FT was performed in 12 healthy volunteers and 9 ischemic heart failure (HF) patients. Cine sequences were acquired using different temporal (20, 30, 40 and 50 frames/cardiac cycle) and spatial resolution parameters (high 1.5 × 1.5 mm in plane and 5 mm slice thickness, standard 1.8 × 1.8 × 8 mm and low 3.0 × 3.0 × 10 mm). Inter- and intra-observer reproducibility were calculated. RESULTS: Increasing temporal resolution is associated with higher absolute strain and strain rate (SR) values. Significant changes in strain assessment for left atrial (LA) total strain occurred between 20 and 30 frames/cycle amounting to 2,5-4,4% in absolute changes depending on spatial resolution settings. From 30 frames/cycle onward, absolute strain values remained unchanged. Significant changes of LA strain rate assessment were observed up to the highest temporal resolution of 50 frames/cycle. Effects of spatial resolution on strain assessment were smaller. For LA total strain a general trend emerged for a mild decrease in strain values obtained comparing the lowest to the highest spatial resolution at temporal resolutions of 20, 40 and 50 frames/cycle (p = 0.006-0.046) but not at 30 frames/cycle (p = 0.140). CONCLUSION: Temporal and to a smaller extent spatial resolution affect atrial functional assessment. Consistent strain assessment requires a standard spatial resolution and a temporal resolution of 30 frames/cycle, whilst SR assessment requires even higher settings of at least 50 frames/cycle.


Subject(s)
Atrial Function, Left , Magnetic Resonance Imaging, Cine , Humans , Reproducibility of Results , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging , Heart Atria/diagnostic imaging , Ventricular Function, Left , Predictive Value of Tests
8.
Front Cardiovasc Med ; 10: 1199936, 2023.
Article in English | MEDLINE | ID: mdl-37636296

ABSTRACT

Background: Strain analyses derived from cardiovascular magnetic resonance-feature tracking (CMR-FT) provide incremental prognostic benefit in patients sufferring from acute myocardial infarction (AMI). This study aims to evaluate and revalidate previously reported prognostic implications of comprehensive strain analyses in a large independent cohort of patients with ST-elevation myocardial infarction (STEMI). Methods: Overall, 566 STEMI patients enrolled in the CONDITIONING-LIPSIA trial including pre- and/or postconditioning treatment in addition to conventional percutaneous coronary intervention underwent CMR imaging in median 3 days after primary percutaneous coronary intervention. CMR-based left atrial (LA) reservoir (Es), conduit (Ee), and boosterpump (Ea) strain analyses, as well as left ventricular (LV) global longitudinal strain (GLS), circumferential strain (GCS), and radial strain (GRS) analyses were carried out. Previously identified cutoff values were revalidated for risk stratification. Major adverse cardiac events (MACE) comprising death, reinfarction, and new congestive heart failure were assessed within 12 months after the occurrence of the index event. Results: Both atrial and ventricular strain values were significantly reduced in patients with MACE (p < 0.01 for all). Predetermined LA and LV strain cutoffs enabled accurate risk assessment. All LA and LV strain values were associated with MACE on univariable regression modeling (p < 0.001 for all), with LA Es emerging as an independent predictor of MACE on multivariable regression modeling (HR 0.92, p = 0.033). Furthermore, LA Es provided an incremental prognostic value above LVEF (a c-index increase from 0.7 to 0.74, p = 0.03). Conclusion: External validation of CMR-FT-derived LA and LV strain evaluations confirmed the prognostic value of cardiac deformation assessment in STEMI patients. In the present study, LA strain parameters especially enabled further risk stratification and prognostic assessment over and above clinically established risk parameters. Clinical Trial Registration: ClinicalTrials.gov, identifier NCT02158468.

9.
J Cardiovasc Magn Reson ; 25(1): 24, 2023 04 13.
Article in English | MEDLINE | ID: mdl-37046343

ABSTRACT

BACKGROUND: Recently, a novel left atrioventricular coupling index (LACI) has been introduced providing prognostic value to predict cardiovascular events beyond common risk factors in patients without cardiovascular disease. Since data on cardiovascular magnetic resonance (CMR)-derived LACI in patients following acute myocardial infarction (AMI) are scarce, we aimed to assess the diagnostic and prognostic implications of LACI in a large AMI patient cohort. METHODS: In total, 1046 patients following AMI were included. After primary percutaneous coronary intervention CMR imaging and subsequent functional analyses were performed. LACI was defined by the ratio of the left atrial end-diastolic volume divided by the left ventricular (LV) end-diastolic volume. Major adverse cardiac events (MACE) including death, reinfarction or heart failure within 12 months after the index event were defined as primary clinical endpoint. RESULTS: LACI was significantly higher in patients with MACE compared to those without MACE (p < 0.001). Youden Index identified an optimal LACI cut-off at 34.7% to classify patients at high-risk (p < 0.001 on log-rank testing). Greater LACI was associated with MACE on univariate regression modeling (HR 8.1, 95% CI 3.4-14.9, p < 0.001) and after adjusting for baseline confounders and LV ejection fraction (LVEF) on multivariate regression analyses (HR 3.1 95% CI 1.0-9, p = 0.049). Furthermore, LACI assessment enabled further risk stratification in high-risk patients with impaired LV systolic function (LVEF ≤ 35%; p < 0.001 on log-rank testing). CONCLUSION: Atrial-ventricular interaction using CMR-derived LACI is a superior measure of outcome beyond LVEF especially in high-risk patients following AMI. Trial registration ClinicalTrials.gov, NCT00712101 and NCT01612312.


Subject(s)
Atrial Fibrillation , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Atrial Fibrillation/etiology , Heart Atria , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prognosis , Stroke Volume , Ventricular Function, Left
10.
ESC Heart Fail ; 10(4): 2307-2318, 2023 08.
Article in English | MEDLINE | ID: mdl-37060191

ABSTRACT

AIMS: There is evidence to suggest that the subtype of aortic stenosis (AS), the degree of myocardial fibrosis (MF), and level of aortic valve calcification (AVC) are associated with adverse cardiac outcome in AS. Because little is known about their respective contribution, we sought to investigate their relative importance and interplay as well as their association with adverse cardiac events following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: One hundred consecutive patients with severe AS and indication for TAVR were prospectively enrolled between January 2017 and October 2018. Patients underwent transthoracic echocardiography, multidetector computed tomography, and left ventricular endomyocardial biopsies at the time of TAVR. The final study cohort consisted of 92 patients with a completed study protocol, 39 (42.4%) of whom showed a normal ejection fraction (EF) high-gradient (NEFHG) AS, 13 (14.1%) a low EF high-gradient (LEFHG) AS, 25 (27.2%) a low EF low-gradient (LEFLG) AS, and 15 (16.3%) a paradoxical low-flow, low-gradient (PLFLG) AS. The high-gradient phenotypes (NEFHG and LEFHG) showed the largest amount of AVC (807 ± 421 and 813 ± 281 mm3 , respectively) as compared with the low-gradient phenotypes (LEFLG and PLFLG; 503 ± 326 and 555 ± 594 mm3 , respectively, P < 0.05). Conversely, MF was most prevalent in low-output phenotypes (LEFLG > LEFHG > PLFLG > NEFHG, P < 0.05). This was paralleled by a greater cardiovascular (CV) mortality within 600 days after TAVR (LEFLG 28% > PLFLG 26.7% > LEFHG 15.4% > NEFHG 2.5%; P = 0.023). In patients with a high MF burden, a higher AVC was associated with a lower mortality following TAVR (P = 0.045, hazard ratio 0.261, 95% confidence interval 0.07-0.97). CONCLUSIONS: MF is associated with adverse CV outcome following TAVR, which is most prevalent in low EF situations. In the presence of large MF burden, patients with large AVC have better outcome following TAVR. Conversely, worse outcome in large MF and relatively little AVC may be explained by a relative prominence of an underlying cardiomyopathy. The better survival rates in large AVC patients following TAVR indicate TAVR induced relief of severe AS-associated pressure overload with subsequently improved outcome.


Subject(s)
Aortic Valve Stenosis , Cardiomyopathies , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Treatment Outcome , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Fibrosis
11.
Eur J Heart Fail ; 25(3): 322-331, 2023 03.
Article in English | MEDLINE | ID: mdl-36691723

ABSTRACT

AIMS: The REDUCE-LAP II trial demonstrated adverse outcomes after interatrial shunt device (IASD) placement in heart failure with preserved ejection fraction (HFpEF) attributed to latent pulmonary vascular disease (PVD). We hypothesized that exercise stress cardiovascular magnetic resonance (CMR) imaging could provide non-invasive characterization of cardiac and pulmonary physiology for improved patient selection. METHODS AND RESULTS: The HFpEF-Stress trial prospectively enrolled 75 patients with exertional dyspnoea and diastolic dysfunction. Patients underwent rest and exercise stress right heart catheterization, echocardiography and CMR imaging. Pulmonary artery and capillary wedge pressures, cardiac index (CI) and pulmonary vascular resistance (PVR) were calculated. Latent PVD was defined as increased PVR ≥ 1.74 Wood units during exercise stress. CMR assessed long-axis strains (LAS) and filling volumes of all cardiac chambers. Right ventricular (RV) function was further quantified by stroke and peak flow volumes. Patients with latent PVD (n = 24) showed lower RV function (rest tricuspid annular plane systolic excursion, p = 0.010; stress RV LAS, p < 0.001) compared to patients without (n = 43). During exercise stress, RV stroke and peak flow volumes (p < 0.001) were reduced and led to impaired left atrial filling (p = 0.040) with a strong statistical trend to impaired ventricular (LV) filling (p = 0.098). This subsequently resulted in reduced LV-CI (p < 0.001) despite preserved LV systolic function (LV LAS p ≥ 0.255). The degree of RV dysfunction during exercise stress best predicted latent PVD (RV peak flow, area under the curve at rest 0.73 vs. stress 0.89, p = 0.004). CONCLUSIONS: Latent PVD is a feature of HFpEF and is associated with impaired RV functional reserve, global diastolic filling and LV-CI. This can be quantified by CMR and used to identify patients likely to benefit from IASD implantation.


Subject(s)
Heart Failure , Stroke , Humans , Heart Failure/complications , Heart Ventricles , Pulmonary Wedge Pressure , Stroke Volume/physiology , Ventricular Function, Left
12.
Sci Rep ; 12(1): 21430, 2022 12 12.
Article in English | MEDLINE | ID: mdl-36509862

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has become the standard treatment for aortic stenosis in older patients. It increasingly relies on accurate pre-procedural planning using multidetector computed tomography (MDCT). Since little is known about the required competence levels for MDCT analyses, we comprehensively assessed MDCT TAVR planning reproducibility and accuracy with regard to valve selection in various healthcare workers. 20 randomly selected MDCT of TAVR patients were analyzed using dedicated software by healthcare professionals with varying backgrounds and experience (two structural interventionalists, one imaging specialist, one cardiac surgeon, one general physician, and one medical student). Following the analysis, the most appropriate Edwards SAPIEN 3™ and Medtronic CoreValve valve size was selected. Intra- and inter-observer variability were assessed. The first structural interventionalist was considered as reference standard for inter-observer comparison. Excellent intra- and inter-observer variability was found for the entire group in regard to the MDCT measurements. The best intra-observer agreement and reproducibility were found for the structural interventionalist, while the medical student had the lowest reproducibility. The highest inter-observer agreement was between both structural interventionalists, followed by the imaging specialist. As to valve size selection, the structural interventionalist showed the highest intra-observer reproducibility, independent of the brand of valve used. Compared to the reference structural interventionalist, the second structural interventionalist showed the highest inter-observer agreement for valve size selection [ICC 0.984, 95% CI 0.969-0.991] followed by the cardiac surgeon [ICC 0.947, 95%CI 0.900-0.972]. The lowest inter-observer agreement was found for the medical student [ICC 0.507, 95%CI 0.067-0.739]. While current state-of-the-art MDCT analysis software provides excellent reproducibility for anatomical measurements, the highest levels of confidence in terms of valve size selection were achieved by the performing interventional physicians. This was most likely attributable to observer experience.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aged , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Multidetector Computed Tomography/methods , Reproducibility of Results , Prosthesis Design , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Observer Variation , Retrospective Studies , Predictive Value of Tests
13.
Radiologie (Heidelb) ; 62(11): 912-919, 2022 Nov.
Article in German | MEDLINE | ID: mdl-36227368

ABSTRACT

BACKGROUND: Myocardial infarction with nonobstructive coronary arteries (MINOCA) accounts for 5-10% of all presentations of acute myocardial infarction. OBJECTIVES: To outline the role of cardiovascular magnetic resonance (CMR) in patients with suspected MINOCA. MATERIALS AND METHODS: Current guidelines for the use of CMR in suspected MINOCA are summarized. Clinical cases with typical CMR findings are presented. RESULTS: In 2019, the American Heart Association published a revised definition of the term MINOCA, which was recently adopted in the European Society of Cardiology 2020 guidelines on acute coronary syndromes without persistent ST-segment elevation (NSTE-ACS). The guidelines indicate that a CMR is recommended (class 1B) in all MINOCA cases with no obvious cause. CONCLUSION: The major strength of CMR imaging is to differentiate nonischemic from ischemic etiologies of myocardial injury. This makes CMR the most important noninvasive diagnostic tool for the differential diagnosis of patients with suspected MINOCA.


Subject(s)
MINOCA , Myocardial Infarction , United States , Humans , Coronary Angiography/adverse effects , Risk Factors , Coronary Vessels/diagnostic imaging , Myocardial Infarction/diagnosis
14.
Eur Heart J Open ; 2(5): oeac053, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36268539

ABSTRACT

Aims: Deformation imaging enables optimized risk prediction following acute myocardial infarction (AMI). However, costly and time-consuming post processing has hindered widespread clinical implementation. Since manual left-ventricular long-axis strain (LV LAS) has been successfully proposed as a simple alternative for LV deformation imaging, we aimed at the validation of left-atrial (LA) LAS. Methods and results: The AIDA STEMI and TATORT-NSTEMI trials recruited 795 patients with ST-elevation myocardial infarction and 440 with non-ST-elevation myocardial infarction. LA LAS was assessed as the systolic distance change between the middle of a line connecting the origins of the mitral leaflets and either a perpendicular line towards the posterior atrial wall (LAS90) or a line connecting to the LA posterior portion of the greatest distance irrespective of a predefined angle (LAS). Primary endpoint was major adverse cardiac event (MACE) occurrence within 12 months. There were no significant differences between LA LAS and LAS90, both with excellent reproducibility. LA LAS correlated significantly with LA reservoir function (Es, r = 0.60, P < 0.001). Impaired LA LAS resulted in higher MACE occurrence [hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.82-0.88, P < 0.001]. LA LAS (HR 0.90, 95% CI 0.83-0.97, P = 0.005) and LV global longitudinal strain (GLS, P = 0.025) were the only independent predictors for MACE in multivariate analyses. C-statistics demonstrated incremental value of LA LAS in addition to GLS (P = 0.016) and non-inferiority compared with FT Es (area under the receiver operating characteristic curve 0.74 vs. 0.69, P = 0.256). Conclusion: Left-atrial LAS provides fast and software-independent approximations of quantitative LA function with similar value for risk prediction compared with dedicated deformation imaging. Clinical trial registration: ClinicalTrials.gov: NCT00712101 and NCT01612312.

15.
Front Cardiovasc Med ; 9: 965512, 2022.
Article in English | MEDLINE | ID: mdl-36082124

ABSTRACT

Background: The risk of myocarditis after mRNA vaccination against COVID-19 has emerged recently. Current evidence suggests that young male patients are predominantly affected. In the majority of the cases, only mild symptoms were observed. However, little is known about cardiac magnetic resonance (CMR) imaging patterns in mRNA-related myocarditis and their differences when compared to classical viral myocarditis in the acute phase of inflammation. Methods and results: In total, 10 mRNA vaccination-associated patients with myocarditis were retrospectively enrolled in this study and compared to 10 patients suffering from viral myocarditis, who were matched for age, sex, comorbidities, and laboratory markers. All patients (n = 20) were hospitalized and underwent a standardized clinical examination, as well as an echocardiography and a CMR. Both, clinical and imaging findings and, in particular, functional and volumetric CMR assessments, as well as detailed tissue characterization using late gadolinium enhancement and T1 + T2-weighted sequences, were compared between both groups. The median age of the overall cohort was 26 years (group 1: 25.5; group 2: 27.5; p = 0.57). All patients described chest pain as the leading reason for their initial presentation. CMR volumetric and functional parameters did not differ significantly between both groups. In all cases, the lateral left ventricular wall showed late gadolinium enhancement without significant differences in terms of the localization or in-depth tissue characterization (late gadolinium enhancement [LGE] enlargement: group 1: 5.4%; group 2: 6.5%; p = 0.14; T2 global/maximum value: group 1: 38.9/52 ms; group 2: 37.8/54.5 ms; p = 0.79 and p = 0.80). Conclusion: This study yielded the first evidence that COVID-19 mRNA vaccine-associated myocarditis does not show specific CMR patterns during the very acute stage in the most affected patient group of young male patients. The observed imaging markers were closely related to regular viral myocarditis in our cohort. Additionally, we could not find any markers implying adverse outcomes in this relatively little number of patients; however, this has to be confirmed by future studies that will include larger sample sizes.

16.
Sci Rep ; 12(1): 12220, 2022 07 18.
Article in English | MEDLINE | ID: mdl-35851282

ABSTRACT

Feasibility of automated volume-derived cardiac functional evaluation has successfully been demonstrated using cardiovascular magnetic resonance (CMR) imaging. Notwithstanding, strain assessment has proven incremental value for cardiovascular risk stratification. Since introduction of deformation imaging to clinical practice has been complicated by time-consuming post-processing, we sought to investigate automation respectively. CMR data (n = 1095 patients) from two prospectively recruited acute myocardial infarction (AMI) populations with ST-elevation (STEMI) (AIDA STEMI n = 759) and non-STEMI (TATORT-NSTEMI n = 336) were analysed fully automated and manually on conventional cine sequences. LV function assessment included global longitudinal, circumferential, and radial strains (GLS/GCS/GRS). Agreements were assessed between automated and manual strain assessments. The former were assessed for major adverse cardiac event (MACE) prediction within 12 months following AMI. Manually and automated derived GLS showed the best and excellent agreement with an intraclass correlation coefficient (ICC) of 0.81. Agreement was good for GCS and poor for GRS. Amongst automated analyses, GLS (HR 1.12, 95% CI 1.08-1.16, p < 0.001) and GCS (HR 1.07, 95% CI 1.05-1.10, p < 0.001) best predicted MACE with similar diagnostic accuracy compared to manual analyses; area under the curve (AUC) for GLS (auto 0.691 vs. manual 0.693, p = 0.801) and GCS (auto 0.668 vs. manual 0.686, p = 0.425). Amongst automated functional analyses, GLS was the only independent predictor of MACE in multivariate analyses (HR 1.10, 95% CI 1.04-1.15, p < 0.001). Considering high agreement of automated GLS and equally high accuracy for risk prediction compared to the reference standard of manual analyses, automation may improve efficiency and aid in clinical routine implementation.Trial registration: ClinicalTrials.gov, NCT00712101 and NCT01612312.


Subject(s)
Artificial Intelligence , Magnetic Resonance Imaging, Cine , Myocardial Infarction , Humans , Magnetic Resonance Imaging, Cine/methods , Myocardial Infarction/diagnostic imaging , Reproducibility of Results , Risk Assessment/methods , ST Elevation Myocardial Infarction/diagnostic imaging
17.
J Cardiovasc Magn Reson ; 24(1): 45, 2022 07 28.
Article in English | MEDLINE | ID: mdl-35897100

ABSTRACT

BACKGROUND: Since cardiovascular magnetic resonance (CMR) imaging allows comprehensive quantification of both myocardial function and structure we aimed to assess myocardial remodeling processes in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: CMR imaging was performed in 40 patients with severe AS before and 1 year after TAVR. Image analyses comprised assessments of myocardial volumes, CMR-feature-tracking based atrial and ventricular strain, myocardial T1 mapping, extracellular volume fraction-based calculation of left ventricular (LV) cellular and matrix volumes, as well as ischemic and non-ischemic late gadolinium enhancement analyses. Moreover, biomarkers including NT-proBNP as well as functional and clinical status were documented. RESULTS: Myocardial function improved 1 year after TAVR: LV ejection fraction (57.9 ± 16.9% to 65.4 ± 14.5%, p = 0.002); LV global longitudinal (- 21.4 ± 8.0% to -25.0 ± 6.4%, p < 0.001) and circumferential strain (- 36.9 ± 14.3% to - 42.6 ± 11.8%, p = 0.001); left atrial reservoir (13.3 ± 6.3% to 17.8 ± 6.7%, p = 0.001), conduit (5.5 ± 3.2% to 8.4 ± 4.6%, p = 0.001) and boosterpump strain (8.2 ± 4.6% to 9.9 ± 4.2%, p = 0.027). This was paralleled by regression of total myocardial volume (90.3 ± 21.0 ml/m2 to 73.5 ± 17.0 ml/m2, p < 0.001) including cellular (55.2 ± 13.2 ml/m2 to 45.3 ± 11.1 ml/m2, p < 0.001) and matrix volumes (20.7 ± 6.1 ml/m2 to 18.8 ± 5.3 ml/m2, p = 0.036). These changes were paralleled by recovery from heart failure (decrease of NYHA class: p < 0.001; declining NT-proBNP levels: 2456 ± 3002 ng/L to 988 ± 1222 ng/L, p = 0.001). CONCLUSION: CMR imaging enables comprehensive detection of myocardial remodeling in patients undergoing TAVR. Regression of LV matrix volume as a surrogate for reversible diffuse myocardial fibrosis is accompanied by increase of myocardial function and recovery from heart failure. Further data are required to define the value of these parameters as therapeutic targets for optimized management of TAVR patients. Trial registration DRKS, DRKS00024479. Registered 10 December 2021-Retrospectively registered, https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00024479.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/surgery , Contrast Media , Gadolinium , Humans , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Prospective Studies , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left , Ventricular Remodeling
18.
Children (Basel) ; 9(6)2022 Jun 12.
Article in English | MEDLINE | ID: mdl-35740815

ABSTRACT

(1) Background: Thermal ablation has been demonstrated to affect the bone growth of osteoid osteoma in adolescents. Growth modulation due to thermal heat in children is conceivable, but has not yet been established. We used lamb extremities as a preclinical model to examine the effect of thermal ablation on growth plates in order to evaluate its potential for axial or longitudinal growth modulation in pediatric patients. (2) Methods: Thermal ablation was performed by electrocautery on eight different growth plates of the legs and distal radii of a stillborn lamb. After treatment, target hits and the physical extent of the growth plate lesions were monitored using micro-computed tomography (micro-CT) and histology. (3) Results: Lesions and their physical extent could be quantified in 75% of the treated extremities. The histological analysis revealed that the disruption of tissue was confined to a small area and the applied heat did not cause the entire growth plate to be disrupted or obviously damaged. (4) Conclusions: Thermal ablation by electrocautery is minimally invasive and can be used for targeted disruption of small areas in growth plates in the animal model. The results suggest that thermal ablation can be developed into a suitable method to influence epiphyseal growth in children.

19.
J Interv Cardiol ; 2022: 1368878, 2022.
Article in English | MEDLINE | ID: mdl-35539443

ABSTRACT

Background: Cardiovascular magnetic resonance imaging is considered the reference standard for assessing cardiac morphology and function and has demonstrated prognostic utility in patients undergoing transcatheter aortic valve replacement (TAVR). Novel fully automated analyses may facilitate data analyses but have not yet been compared against conventional manual data acquisition in patients with severe aortic stenosis (AS). Methods: Fully automated and manual biventricular assessments were performed in 139 AS patients scheduled for TAVR using commercially available software (suiteHEART®, Neosoft; QMass®, Medis Medical Imaging Systems). Volumetric assessment included left ventricular (LV) mass, LV/right ventricular (RV) end-diastolic/end-systolic volume, LV/RV stroke volume, and LV/RV ejection fraction (EF). Results of fully automated and manual analyses were compared. Regression analyses and receiver operator characteristics including area under the curve (AUC) calculation for prediction of the primary study endpoint cardiovascular (CV) death were performed. Results: Fully automated and manual assessment of LVEF revealed similar prediction of CV mortality in univariable (manual: hazard ratio (HR) 0.970 (95% CI 0.943-0.997) p=0.032; automated: HR 0.967 (95% CI 0.939-0.995) p=0.022) and multivariable analyses (model 1: (including significant univariable parameters) manual: HR 0.968 (95% CI 0.938-0.999) p=0.043; automated: HR 0.963 [95% CI 0.933-0.995] p=0.024; model 2: (including CV risk factors) manual: HR 0.962 (95% CI 0.920-0.996) p=0.027; automated: HR 0.954 (95% CI 0.920-0.989) p=0.011). There were no differences in AUC (LVEF fully automated: 0.686; manual: 0.661; p=0.21). Absolute values of LV volumes differed significantly between automated and manual approaches (p < 0.001 for all). Fully automated quantification resulted in a time saving of 10 minutes per patient. Conclusion: Fully automated biventricular volumetric assessments enable efficient and equal risk prediction compared to conventional manual approaches. In addition to significant time saving, this may provide the tools for optimized clinical management and stratification of patients with severe AS undergoing TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Artificial Intelligence , Humans , Risk Assessment , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Ventricular Function, Left
20.
J Clin Med ; 10(17)2021 Sep 02.
Article in English | MEDLINE | ID: mdl-34501418

ABSTRACT

Aortic valve calcification (AVC) in aortic stenosis patients has diagnostic and prognostic implications. Little is known about the interchangeability of AVC obtained from different multidetector computed tomography (MDCT) software solutions. Contrast-enhanced MDCT data sets of 50 randomly selected aortic stenosis patients were analysed using three different software vendors (3Mensio, CVI42, Syngo.Via). A subset of 10 patients were analysed twice for the estimation of intra-observer variability. Intra- and inter-observer variability were determined using the ICC reliability method, Bland-Altman analysis and coefficients of variation. No differences were revealed between the software solutions in the AVC calculations (3Mensio 941 ± 623, Syngo.Via 948 mm3 ± 655, CVI42 941 ± 637; p = 0.455). The best inter-vendor agreement was found between the CVI42 and the Syngo.Via (ICC 0.997 (CI 0.995-0.998)), followed by the 3Mensio and the CVI42 (ICC 0.996 (CI 0.922-0.998)), and the 3Mensio and the Syngo.Via (ICC 0.992 (CI 0.986-0.995)). There was excellent intra- (3Mensio: ICC 0.999 (0.995-1.000); CVI42: ICC 1.000 (0.999-1.000); Syngo.Via: ICC 0.998 (0.993-1.000)) and inter-observer variability (3Mensio: ICC 1.000 (0.999-1.000); CVI42: ICC 1.000 (1.000-1.000); Syngo.Via: ICC 0.996 (0.985-0.999)) for all software types. Contrast-enhanced MDCT-derived AVC scores are interchangeable between and reproducible within different commercially available software solutions. This is important since sufficient reproducibility, interchangeability and valid results represent prerequisites for accurate TAVR planning and its widespread clinical use.

SELECTION OF CITATIONS
SEARCH DETAIL
...