Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 30(1): 112-124, 2022 Jan 03.
Article in English | MEDLINE | ID: mdl-35201185

ABSTRACT

Optical scanners are widely used in high-resolution scientific, medical, and industrial devices. The accuracy and precision of these instruments are often limited by angular speed fluctuations due to rotational inertia and by poor synchronization between scanning and light detection, respectively. Here we demonstrate that both problems can be mitigated by recording scanner orientation in synchrony with light detection, followed by data resampling. This approach is illustrated with synthetic and experimental data from a point-scanning microscope with a resonant scanner and a non-resonant scanner. Fitting of the resonant scanner orientation data to a cosine model was used to correct image warping and sampling jitter, as well as to precisely interleave image lines collected during the clockwise and counterclockwise resonant scanner portions of the rotation cycle. Vertical scanner orientation data interpolation was used to correct image distortion due to angular speed fluctuations following abrupt control signal changes.

2.
Materials (Basel) ; 15(1)2022 Jan 05.
Article in English | MEDLINE | ID: mdl-35009523

ABSTRACT

This paper presents the results of the experimental research of 3D structures developed with an SLA additive technique using Durable Resin V2. The aim of this paper is to evaluate and compare the compression curves, deformation process and energy-absorption parameters of the topologies with different characteristics. The structures were subjected to a quasi-static axial compression test. Five different topologies of lattice structures were studied and compared. In the initial stage of the research, the geometric accuracy of the printed structures was analysed through measurement of the diameter of the beam elements at several selected locations. Compression curves and the stress history at the minimum cross-section of each topology were determined. Energy absorption parameters, including absorbed energy (AE) and specific absorbed energy (SAE), were calculated from the compression curves. Based on the analysis of the photographic material, the failure mode was analysed, and the efficiency of the topologies was compared.

3.
Biomed Opt Express ; 12(10): 6496-6513, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34745752

ABSTRACT

An off-axis monocular pupil tracker designed for eventual integration in ophthalmoscopes for eye movement stabilization is described and demonstrated. The instrument consists of light-emitting diodes, a camera, a field-programmable gate array (FPGA) and a central processing unit (CPU). The raw camera image undergoes background subtraction, field-flattening, 1-dimensional low-pass filtering, thresholding and robust pupil edge detection on an FPGA pixel stream, followed by least-squares fitting of the pupil edge pixel coordinates to an ellipse in the CPU. Experimental data suggest that the proposed algorithms require raw images with a minimum of ∼32 gray levels to achieve sub-pixel pupil center accuracy. Tests with two different cameras operating at 575, 1250 and 5400 frames per second trained on a model pupil achieved 0.5-1.5 µm pupil center estimation precision with 0.6-2.1 ms combined image download, FPGA and CPU processing latency. Pupil tracking data from a fixating human subject show that the tracker operation only requires the adjustment of a single parameter, namely an image intensity threshold. The latency of the proposed pupil tracker is limited by camera download time (latency) and sensitivity (precision).

4.
Biomed Opt Express ; 12(2): 737-755, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33680539

ABSTRACT

Quadrant reflectance confocal and non-confocal scanning light ophthalmoscope images of the photoreceptor mosaic were recorded in a subject with congenital achromatopsia (ACHM) and a normal control. These images, captured with various circular and annular apertures, were used to calculate split-detection images, revealing two cone photoreceptor contrast mechanisms. The first contrast mechanism, maximal in the non-confocal 5.5-10 Airy disk diameter annular region, is unrelated to the cone reflectivity in confocal or flood illumination imaging. The second mechanism, maximal for confocal split-detection, is related to the cone reflectivity in confocal or flood illumination imaging that originates from the ellipsoid zone and/or inner-outer segment junction. Seeking to maximize image contrast, split-detection images were generated using various quadrant detector combinations, with opposite (diagonal) quadrant detectors producing the highest contrast. Split-detection generated with the addition of adjacent quadrant detector pairs, shows lower contrast, while azimuthal split-detection images, calculated from adjacent quadrant detectors, showed the lowest contrast. Finally, the integration of image pairs with orthogonal split directions was used to produce images in which the photoreceptor contrast does not change with direction.

5.
Appl Opt ; 60(36): 11189-11195, 2021 Dec 20.
Article in English | MEDLINE | ID: mdl-35201107

ABSTRACT

Dynamic mirror deformation can substantially degrade the performance of optical instruments using resonant scanners. Here, we evaluate two scanners with resonant frequencies >12kHz with low dynamic distortion. First, we tested an existing galvanometric motor with a novel, to the best of our knowledge, mirror substrate material, silicon carbide, which resonates at 13.8 kHz. This material is stiffer than conventional optical glasses and has lower manufacturing toxicity than beryllium, the stiffest material currently used for this application. Then, we tested a biaxial microelectromechanical (MEMS) scanner with the resonant axis operating at 29.4 kHz. Dynamic deformation measurements show that wavefront aberrations in the galvanometric scanner are dominated by linear oblique astigmatism (90%), while wavefront aberrations in the MEMS scanner are dominated by horizontal coma (30%) and oblique trefoil (27%). In both scanners, distortion amplitude increases linearly with deflection angle, yielding diffraction-limited performance over half of the maximum possible deflection for wavelengths longer than 450 nm and over the full deflection range for wavelengths above 850 nm. Diffraction-limited performance for shorter wavelengths or over larger fractions of the deflection range can be achieved by reducing the beam diameter at the mirror surface. The small dynamic distortion of the MEMS scanner offers a promising alternative to galvanometric resonant scanners with desirable but currently unattainably high resonant frequencies.

6.
Optica ; 7(11): 1506-1513, 2020 Nov.
Article in English | MEDLINE | ID: mdl-34368405

ABSTRACT

High-speed optical systems are revolutionizing biomedical imaging in microscopy, DNA sequencing, and flow cytometry, as well as numerous other applications, including data storage, display technologies, printing, and autonomous vehicles. These systems often achieve the necessary imaging or sensing speed through the use of resonant galvanometric optical scanners. Here, we show that the optical performance of these devices suffers due to the dynamic mirror distortion that arises from the variation in torque with angular displacement. In one of two scanners tested, these distortions result in a variation of signal-to-noise (Strehl) ratio by an order of magnitude across the field of view, degrading transverse resolution by more than a factor of 2. This mirror distortion could be mitigated through the use of stiffer materials, such as beryllium or silicon carbide, at the expense of surface roughness, as these cannot be polished to the same degree of smoothness as common optical glasses. The repeatability of the dynamic distortion indicates that computational and optical corrective methods are also possible.

SELECTION OF CITATIONS
SEARCH DETAIL
...