Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
EJNMMI Res ; 14(1): 63, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38976101

ABSTRACT

BACKGROUND: Positron emission tomography (PET) is now an established diagnostic method for myocardial perfusion imaging (MPI) in coronary artery disease, which is the main cause of death globally. The available tracers show several limitations, therefore, the 18F-labelled tracer is in high demand nowadays. The preclinical studies on normal Wistar rats aimed to characterise two potential, novel radiotracers, [18F]SYN1 and [18F]SYN2, to evaluate which is a better candidate for PET MPI cardiotracer. RESULTS: The dynamic microPET images showed rapid myocardial uptake for both tracers. However, the uptake was higher and also stable for [18F]SYN2, with an average standardized uptake value of 3.8. The biodistribution studies confirmed that [18F]SYN2 uptake in the cardiac muscle was high and stable (3.02%ID/g at 15 min and 2.79%ID/g at 6 h) compared to [18F]SYN1 (1.84%ID/g at 15 min and 0.32%ID/g at 6 h). The critical organs determined in dosimetry studies were the small intestine and the kidneys. The estimated effective dose for humans was 0.00714 mSv/MBq for [18F]SYN1 and 0.0109 mSv/MBq for [18F]SYN2. The tested dose level of 2 mg/kg was considered to be the No Observed Adverse Effect Level (NOAEL) for both candidates. The better results were achieved for [18F]SYN2, therefore, further preclinical studies were conducted only for this tracer. Radioligand binding assays showed significant responses in 3 from 68 assays: muscarinic acetylcholine M1 and M2 receptors and potassium channel hERG. The compound was mostly metabolised via an oxidative N-dealkylation, while the fluor substituent was not separated from the molecule. CONCLUSION: [18F]SYN2 showed a favourable pharmacodynamic and pharmacokinetic profile, which enabled a clear visualization of the heart in microPET. The compound was well-tolerated in studies in normal rats with moderate radiation exposure. The results encourage further exploration of [18F]SYN2 in clinical studies.

2.
Appl Radiat Isot ; 109: 242-246, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26553157

ABSTRACT

Radionuclidic purity tests of (18)F radiopharmaceuticals (Na(18)F and fluorodeoxyglucose [(18)F]FDG) and radionuclide composition analysis of irradiated water [(18)O]H2O were performed. The measurements were conducted using a High-Purity Germanium (HPGe) detector and a liquid scintillation counter. Radionuclide identification and activity measurements were performed for samples from different stages of the production process. Most of the impurities were detected on QMA (quaternary methylammonium) anion exchange columns and in liquid wastes. Using liquid scintillation counting, the activity of (3)H resulting from the (18)O[p, (3)H](16)O reaction was determined. It was shown that all of the impurities were efficiently determined and eliminated in the radiopharmaceuticals synthesis process and that the final products meet the requirements set by relevant regulations.


Subject(s)
Drug Compounding/standards , Drug Contamination/prevention & control , Fluorine Radioisotopes/analysis , Fluorine Radioisotopes/standards , Radiometry/methods , Radiometry/standards , Materials Testing , Poland , Quality Control , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...