Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 93(4): 043102, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35489906

ABSTRACT

We report the development of a multipurpose differential x-ray calorimeter with a broad energy bandwidth. The absorber architecture is combined with a Bayesian unfolding algorithm to unfold high energy x-ray spectra generated in high-intensity laser-matter interactions. Particularly, we show how to extract absolute energy spectra and how our unfolding algorithm can reconstruct features not included in the initial guess. The performance of the calorimeter is evaluated via Monte Carlo generated data. The method accuracy to reconstruct electron temperatures from bremsstrahlung is shown to be 5% for electron temperatures from 1 to 50 MeV. We study bremsstrahlung generated in solid target interaction showing an electron temperature of 0.56 ± 0.04 MeV for a 700 µm Ti titanium target and 0.53 ± 0.03 MeV for a 50 µm target. We investigate bremsstrahlung from a target irradiated by laser-wakefield accelerated electrons showing an endpoint energy of 551 ± 5 MeV, inverse Compton generated x rays with a peak energy of 1.1 MeV, and calibrated radioactive sources. The total energy range covered by all these sources ranges from 10 keV to 551 MeV.

2.
Rev Sci Instrum ; 87(8): 083310, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27587116

ABSTRACT

In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

3.
Nat Commun ; 3: 874, 2012 Jun 06.
Article in English | MEDLINE | ID: mdl-22673901

ABSTRACT

High-intensity laser plasma-based ion accelerators provide unsurpassed field gradients in the megavolt-per-micrometer range. They represent promising candidates for next-generation applications such as ion beam cancer therapy in compact facilities. The weak scaling of maximum ion energies with the square-root of the laser intensity, established for large sub-picosecond class laser systems, motivates the search for more efficient acceleration processes. Here we demonstrate that for ultrashort (pulse duration ~30 fs) highly relativistic (intensity ~10(21) W cm(-2)) laser pulses, the intra-pulse phase of the proton acceleration process becomes relevant, yielding maximum energies of around 20 MeV. Prominent non-target-normal emission of energetic protons, reflecting an engineered asymmetry in the field distribution of promptly accelerated electrons, is used to identify this pre-thermal phase of the acceleration. The relevant timescale reveals the underlying physics leading to the near-linear intensity scaling observed for 100 TW class table-top laser systems.

4.
Rev Sci Instrum ; 83(12): 123301, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23277976

ABSTRACT

In recent years, a new generation of high repetition rate (~10 Hz), high power (~100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of ~1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

5.
Phys Med Biol ; 56(6): 1529-43, 2011 Mar 21.
Article in English | MEDLINE | ID: mdl-21325708

ABSTRACT

An integrated dosimetry and cell irradiation system (IDOCIS) with laser-accelerated proton beams was developed, characterized, calibrated and successfully used for systematic in vitro experiments. Due to the broad exponentially shaped energy spectrum, the low-energy range of the protons (<20 MeV) and the high pulse dose, the absolute dosimetry for this beam quality is challenging. Therefore, a dedicated Faraday cup is used as an energy and dose rate independent absolute dosimeter that has been calibrated consistently with three independent methods. A transmission ionization chamber providing online relative dose information is cross-calibrated against the Faraday cup. Providing both online and absolute dose information, the IDOCIS allows for quantitative dosimetric and radiobiological studies at current low-energy laser-accelerated proton beams. Finally, first dosimetric characterizations of a laser-accelerated proton beam with the IDOCIS are presented.


Subject(s)
Cells/radiation effects , Lasers , Radiometry/instrumentation , Radiotherapy, High-Energy/instrumentation , Calibration , Humans , Protons , Radiometry/methods , Radiotherapy Dosage , Radiotherapy, High-Energy/methods
6.
Phys Rev E Stat Nonlin Soft Matter Phys ; 82(1 Pt 2): 016405, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20866745

ABSTRACT

A new scheme to efficiently accelerate protons by a single linear polarized high-intensity ultrashort laser pulse using multiple ultrathin foils is proposed. The foils are stacked at a spacing comparable to their thickness and subsequently irradiated by the same laser pulse. The foil thicknesses are chosen such that the laser light pressure can displace all electrons out of the foil. The authors present a simple, yet precise dynamical model of the acceleration process from which both optimum foil thickness and spacing can be derived. Extensive two-dimensional (2D) particle-in-cell simulations verify the model predictions and suggest an enhancement of the maximum proton kinetic energy by 30% for the two-foil case compared to a single foil.

7.
Rev Sci Instrum ; 81(3): 033301, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20370164

ABSTRACT

We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm(2). The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm(2) was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

8.
Rev Sci Instrum ; 81(1): 013307, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20113093

ABSTRACT

The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source.


Subject(s)
Electrons , X-Ray Film , Calibration , Linear Models , Luminescence , Particle Accelerators , Time Factors , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...