Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Adv ; 10(1): eadi9171, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38181074

ABSTRACT

Reducing the form factor while retaining the radiation hardness and performance matrix is the goal of avionics. While a compromise between a transistor's size and its radiation hardness has reached consensus in microelectronics, the size-performance balance for their optical counterparts has not been quested but eventually will limit the spaceborne photonic instruments' capacity to weight ratio. Here, we performed space experiments of photonic integrated circuits (PICs), revealing the critical roles of energetic charged particles. The year-long cosmic radiation exposure does not change carrier mobility but reduces free carrier lifetime, resulting in unchanged electro-optic modulation efficiency and well-expanded optoelectronic bandwidth. The diversity and statistics of the tested PIC modulator indicate the minimal requirement of shielding for PIC transmitters with small footprint modulators and complexed routing waveguides toward lightweight space terminals for terabits communications and intersatellite ranging.

2.
Biosens Bioelectron ; 141: 111396, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31195197

ABSTRACT

Mode volume overlap factor is one of the parameters determining the sensitivity of a sensor. In past decades, many approaches have been proposed to increase the mode volume overlap. As the increased mode volume overlap factor results in reduced mode confinement, the maximum value is ultimately determined by the micro- and nano-structure of the refractive index distribution of the sensing devices. Due to the asymmetric index profile along the vertical direction on silicon-on-insulator platform, further increasing the sensitivity of subwavelength grating metamaterial (SGM) waveguide based sensors is challenging. In this paper, we propose and demonstrate pedestaled SGM which reduces the asymmetricity and thus allows further increasing the interaction between optical field and analytes. The pedestal structure can be readily formed by a controlled undercut etching. Both theoretical analysis and experimental demonstration show a significant improvement of sensitivity. The bulk sensitivity and surface sensitivity are improved by 28.8% and 1000 times, respectively. The detection of streptavidin at a low concentration of 0.1 ng/mL (∼1.67 pM) is also demonstrated through real-time monitoring of the resonance shift. A ∼400 fM streptavidin limit of detection is expected with a 0.01nm resolution spectrum analyzer based on the real-time measurement of streptavidin detection results from two-site binding model fitting.


Subject(s)
Biosensing Techniques/instrumentation , Refractometry/instrumentation , Algorithms , Equipment Design , Silicon/chemistry , Streptavidin/analysis
3.
Opt Express ; 23(23): 30020-7, 2015 Nov 16.
Article in English | MEDLINE | ID: mdl-26698483

ABSTRACT

We describe a Fabry-Perot etalon spectrometer with a novel light recirculation scheme to generate simultaneous parallel wavelength channels with no moving parts. This design uses very simple optics to recirculate light reflected from near normal incidence from the etalon at successively higher angles of incidence. The spectrometer has the full resolution of a Fabry-Perot with significantly improved photon efficiency in a compact, simple design with no moving parts. We present results from a conceptual prototype and a corresponding model.

4.
Opt Express ; 21(2): 1865-71, 2013 Jan 28.
Article in English | MEDLINE | ID: mdl-23389171

ABSTRACT

Laser communication and ranging experiments were successfully conducted from the satellite laser ranging (SLR) station at NASA Goddard Space Flight Center (GSFC) to the Lunar Reconnaissance Orbiter (LRO) in lunar orbit. The experiments used 4096-ary pulse position modulation (PPM) for the laser pulses during one-way LRO Laser Ranging (LR) operations. Reed-Solomon forward error correction codes were used to correct the PPM symbol errors due to atmosphere turbulence and pointing jitter. The signal fading was measured and the results were compared to the model.


Subject(s)
Information Storage and Retrieval/methods , Lasers , Models, Theoretical , Signal Processing, Computer-Assisted/instrumentation , Spacecraft/instrumentation , Telecommunications/instrumentation , Computer Simulation , Equipment Design , Equipment Failure Analysis
5.
Appl Opt ; 50(7): 1047-56, 2011 Mar 01.
Article in English | MEDLINE | ID: mdl-21364729

ABSTRACT

We demonstrate a wavelength-locked laser source that rapidly steps through six wavelengths distributed across a 1572.335 nm carbon dioxide (CO(2)) absorption line to allow precise measurements of atmospheric CO(2) absorption. A distributed-feedback laser diode (DFB-LD) was frequency-locked to the CO(2) line center by using a frequency modulation technique, limiting its peak-to-peak frequency drift to 0.3 MHz at 0.8 s averaging time over 72 hours. Four online DFB-LDs were then offset locked to this laser using phase-locked loops, retaining virtually the same absolute frequency stability. These online and two offline DFB-LDs were subsequently amplitude switched and combined. This produced a precise wavelength-stepped laser pulse train, to be amplified for CO(2) measurements.

6.
Opt Express ; 18(22): 22781-8, 2010 Oct 25.
Article in English | MEDLINE | ID: mdl-21164616

ABSTRACT

A 1542-nm planar-waveguide external cavity laser (PW-ECL) is shown to have a sufficiently low level of noise to be suitable for precision measurement applications. Its frequency noise and intensity noise was comparable or better than the non-planar ring oscillator (NPRO) and fiber laser between 0.1 mHz to 100 kHz. Controllability of the PW-ECL was demonstrated by stabilizing its frequency to acetylene ((13)C(2)H(2)) at 10(-13) level of Allan deviation. The PW-ECL also has the advantage of the compactness of a standard butterfly package, low cost, and a simple design consisting of a semiconductor gain media coupled to a planar-waveguide Bragg reflector.

7.
Appl Opt ; 43(15): 3110-21, 2004 May 20.
Article in English | MEDLINE | ID: mdl-15176200

ABSTRACT

The design and preliminary tests of an automated differential absorption lidar (DIAL) that profiles water vapor in the lower troposphere are presented. The instrument, named CODI (for compact DIAL), has been developed to be eye safe, low cost, weatherproof, and portable. The lidar design and its unattended operation are described. Nighttime intercomparisons with in situ sensors and a radiosonde are shown. Desired improvements to the lidar, including a more powerful laser, are also discussed.