Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 168
Filter
1.
Water Res ; 242: 120228, 2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37348420

ABSTRACT

Micropollutants are regularly detected at the outlets of wastewater treatment plants (WWTPs). Across urban and industrial WWTPs, monitoring directives only require assessment for a handful of chemicals via sampling methods that fail to capture the temporal variability in micropollutant discharge. In this study, we develop a biotest for real-time on-line monitoring of micropollutant discharge dynamics in WWTPs effluents. The selected biomonitoring device ToxMate uses videotracking of invertebrate movement, which was used to deduce avoidance behaviour of the amphipod Gammarus fossarum. Organism conditioning was set up to induce a state of minimal locomotor activity in basal conditions to maximise avoidance signal sensitivity to micropollutant spikes. We showed that with a standardised protocol, it was possible to minimise both overall movement and sensitivity to physio-chemical variations typical to WWTP effluents, as well as capture the spikes of two micropollutants upon exposure (copper and methomyl). Spikes in avoidance behaviour were consistently seen for the two chemicals, as well as a strong correlation between avoidance intensity and spiked concentration. A two-year effluent monitoring case study also illustrates how this biomonitoring method is suitable for real-time on-site monitoring, and shows a promising non-targeted approach for characterising complex micropollutant discharge variability at WWTP effluents, which today remains poorly understood.


Subject(s)
Amphipoda , Water Pollutants, Chemical , Water Purification , Animals , Wastewater , Avoidance Learning , Water Pollutants, Chemical/chemistry , Environmental Monitoring , Waste Disposal, Fluid/methods
2.
Water Sci Technol ; 85(5): 1363-1371, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35290217

ABSTRACT

Historically, green infrastructure for stormwater management has been event-based designed. This study aims to realign the green infrastructure design strategies with principles for robust decision making, through the example of green roofs design with the variational method and exemplified using the Norwegian context of the 3-step approach (3SA) for stormwater management. The 3SA consists of planning solutions to handle day-to-day rain at site scale through infiltration (step 1) and detention (step 2), and extreme events with safe floodways (step 3). An innovative framework based on downscaling of rainfall timeseries is suggested as follows: (i) long duration continuous simulation for retention variation and day-to-day discharge, corresponding to step 1 in the 3SA; (ii) intensive sampling of local extreme events to estimate reliability and robustness of solutions, corresponding to steps 2 and 3 in the 3SA. Comparing the traditional variational method to Highly-Informed-Design-Evaluation-Strategy (HIDES), it was found that the variational method possibly leads to incorrect decisions while the suggested novel approach was found to give more informed and reliable results by suggesting a design based on both operating mode and failure mode. It allows to embed solutions within the urban water system by facilitating the link between the steps of the 3SA. Such a framework was found to be data-wise applicable in the Norwegian context.


Subject(s)
Rain , Water Movements , Reproducibility of Results , Time Factors , Water
3.
Sci Total Environ ; 651(Pt 2): 1810-1818, 2019 Feb 15.
Article in English | MEDLINE | ID: mdl-30316097

ABSTRACT

The assessment of micropollutants in urban wet weather discharges is essential to improve the knowledge of the impact of such discharges on receiving waters. This study assessed the quality of combined sewer overflows (CSOs) in Ecully (residential catchment) and stormwater runoff in Chassieu (industrial catchment) during rain events by providing data on occurrence and total event mean concentrations (EMCt) of 34 priority substances (PS) (9 metals, 13 pesticides, 6 PAHs, 4 alkylphenols and 2 chlorobenzenes) in dissolved and particulate fractions. Over 34 substances monitored, 23 were quantified in urban wet weather discharges of both catchments. For both catchments, 9 metals and 6 PAHs monitored were always quantified, reflecting their ubiquitous presence. For other organic pollutants, only 5 pesticides were quantified and only 2 alkyphenols were measured solely in dissolved fraction. A significant site-to-site difference was observed for metals, PAHs and alkylphenols. The highest concentrations were measured in stormwater runoff in Chassieu vs. Ecully. On the contrary, the diuron concentrations were highest in CSO discharges in Ecully. Distribution of the PS between particulate and dissolved fractions provides information for urban stormwater practitioners. Most PS in urban wet weather discharges were mainly linked to particles (PAHs, Pb, Ti for example). The comparison between daily flows of wastewater treatment plants during dry weather and CSOs daily flows in Ecully showed that stormwater was the most important source of contamination for fluoranthene, benzo(b)fluoranthene and benzo(k)fluoranthene and 7 metals (As, Cr, Co, Cu, Pb, Ti and Zn) in receiving water bodies, but not for pesticides and alkylphenols.

5.
Water Sci Technol ; 66(6): 1325-32, 2012.
Article in English | MEDLINE | ID: mdl-22828313

ABSTRACT

Open-channel junctions are common occurrences in sewer networks and flow rate measurement often occurs near these singularities. Local flow structures are 3D, impact on the representativeness of the local flow measurements and thus lead to deviations in the flow rate estimation. The present study aims (i) to measure and simulate the flow pattern in a junction flow, (ii) to analyse the impact of the junction on the velocity distribution according to the distance from the junction and thus (iii) to evaluate the typical error derived from the computation of the flow rate close to the junction.


Subject(s)
Models, Theoretical , Sanitary Engineering/methods , Water Movements , Computer Simulation , Time Factors
6.
Water Res ; 46(20): 6836-56, 2012 Dec 15.
Article in English | MEDLINE | ID: mdl-22221336

ABSTRACT

This paper presents one of the largest databases on the quality of urban wet weather discharges measured since the development of continuous in-sewer water quality sensors in the late 1990s. Five years of continuous turbidity measurements enabled the validation of 263 and 239 rainfall events, respectively on two experimental catchments in Lyon (France), Chassieu (185 ha separate sewer) and Ecully (245 ha combined sewer). Except for high rainfall events of summer and second half of winter, analysis of database representativeness showed that all seasons were relatively well represented. As a first analysis of the database, traditional tools used in the urban drainage field were applied to assess: i) statistics and analysis of distributions of TSS and COD events loads and event mean concentrations (EMCs) and ii) the correlations between these statistics and events characteristics and iii) M(V) curves describing the intra-event mass distribution. Results showed that: i) EMCs and loads were approximately log-normally distributed, with a clear impact from wastewater contribution in Ecully, ii) EMCs are not correlated with storm event characteristics, whereas loads have shown significant correlation with key storm event variables such as total event volume, rainfall depth, maximum rainfall intensity and discharge and iii) M(V) curves dynamic could be classified in three categories, however with no clear correlation with storm event characteristics. The visual analysis of continuous time series of TSS and COD pollutographs, derived from turbidity time series showed that event pollutographs were highly variable, due to complex interacting processes during and between events, and suggests that further progress in knowledge and modelling of urban wet weather pollutant loads and pollutographs should be based on more detailed analyses of continuous time series rather, than on the traditional single event approach.


Subject(s)
Cities , Environmental Monitoring/methods , Nephelometry and Turbidimetry/instrumentation , Nephelometry and Turbidimetry/methods , Rain , Water Pollutants, Chemical/chemistry , Time Factors , Water Movements
7.
Water Sci Technol ; 63(12): 2983-91, 2011.
Article in English | MEDLINE | ID: mdl-22049728

ABSTRACT

Continuous high resolution long term turbidity measurements along with continuous discharge measurements are now recognised as an appropriate technique for the estimation of in sewer total suspended solids (TSS) and Chemical Oxygen Demand (COD) loads during storm events. In the combined system of the Ecully urban catchment (Lyon, France), this technique is implemented since 2003, with more than 200 storm events monitored. This paper presents a method for the estimation of the dry weather (DW) contribution to measured total TSS and COD event loads with special attention devoted to uncertainties assessment. The method accounts for the dynamics of both discharge and turbidity time series at two minutes time step. The study is based on 180 DW days monitored in 2007-2008. Three distinct classes of DW days were evidenced. Variability analysis and quantification showed that no seasonal effect and no trend over the year were detectable. The law of propagation of uncertainties is applicable for uncertainties estimation. The method has then been applied to all measured storm events. This study confirms the interest of long term continuous discharge and turbidity time series in sewer systems, especially in the perspective of wet weather quality modelling.


Subject(s)
Droughts , Rain , Sewage/chemistry , Water Movements , Water Supply/analysis , Biological Oxygen Demand Analysis , France , Models, Theoretical , Suspensions , Urbanization , Water Supply/standards , Water Supply/statistics & numerical data
8.
Water Sci Technol ; 64(9): 1926-34, 2011.
Article in English | MEDLINE | ID: mdl-22020489

ABSTRACT

An empirical model for TSS event mean concentrations in storm weather discharges has been derived from the analysis of data sets collected in two experimental catchments (Chassieu, separate system and Ecully, combined system) in Lyon, France. Preliminary tests have shown that the values of TSS EMCs were linked to the variable X =TP ×ADWP (TP rainfall depth, ADWP antecedent dry weather period) with two distinct behaviours under and above a threshold value of X named λ: EMCs are increasing if X < λ and are decreasing if X > λ. An empirical equation is proposed for both behaviours. A specific calibration method is used to calibrate λ while the 4 other parameters of the model are calibrated by means of the Levenberg-Marquardt algorithm. The calibration results obtained with 8 events in both sites indicate that the model calibration is satisfactory: Nash Sutcliffe coefficients are all above 0.7. Monte Carlo simulations indicate a low variability of the model parameters for both sites. The model verification with 5 events in Chassieu shows maximum levels of uncertainty of approximately 20%, equivalent to levels of uncertainty observed in the calibration phase.


Subject(s)
Cyclonic Storms , Models, Chemical , Water Pollutants/analysis , Water/chemistry , Algorithms , Calibration , Computer Simulation , France , Probability , Rain
9.
Water Sci Technol ; 63(3): 369-76, 2011.
Article in English | MEDLINE | ID: mdl-21278456

ABSTRACT

With the increasing implementation of continuous monitoring of both discharge and water quality in sewer systems, large data bases are now available. In order to manage large amounts of data and calculate various variables and indicators of interest it is necessary to apply automated methods for data processing. This paper deals with the processing of short time step turbidity time series to estimate TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) event loads in sewer systems during storm events and their associated uncertainties. The following steps are described: (i) sensor calibration, (ii) estimation of data uncertainties, (iii) correction of raw data, (iv) data pre-validation tests, (v) final validation, and (vi) calculation of TSS and COD event loads and estimation of their uncertainties. These steps have been implemented in an integrated software tool. Examples of results are given for a set of 33 storm events monitored in a stormwater separate sewer system.


Subject(s)
Environmental Monitoring/methods , Rain/chemistry , Uncertainty , Water Pollutants, Chemical/analysis , Nephelometry and Turbidimetry , Reproducibility of Results , Time Factors , User-Computer Interface
10.
Water Sci Technol ; 62(4): 875-82, 2010.
Article in English | MEDLINE | ID: mdl-20729591

ABSTRACT

Regression models are among the most frequently used models to estimate pollutants event mean concentrations (EMC) in wet weather discharges in urban catchments. Two main questions dealing with the calibration of EMC regression models are investigated: i) the sensitivity of models to the size and the content of data sets used for their calibration, ii) the change of modelling results when models are re-calibrated when data sets grow and change with time when new experimental data are collected. Based on an experimental data set of 64 rain events monitored in a densely urbanised catchment, four TSS EMC regression models (two log-linear and two linear models) with two or three explanatory variables have been derived and analysed. Model calibration with the iterative re-weighted least squares method is less sensitive and leads to more robust results than the ordinary least squares method. Three calibration options have been investigated: two options accounting for the chronological order of the observations, one option using random samples of events from the whole available data set. Results obtained with the best performing non linear model clearly indicate that the model is highly sensitive to the size and the content of the data set used for its calibration.


Subject(s)
Calibration , Cyclonic Storms , Water/standards , Forecasting , France , Models, Theoretical , Random Allocation , Regression Analysis , Reproducibility of Results , Sewage/analysis , Water Movements
11.
Water Sci Technol ; 57(10): 1651-8, 2008.
Article in English | MEDLINE | ID: mdl-18520024

ABSTRACT

In situ spectrometers are comparable robust instruments and can be operated long term with relatively low maintenance demand. The decisive factor for their applicability is the development of a medium and installation location specific correlation model, which estimates the concentration of the requested target parameter from the measured absorption values. In some cases it might turn out, that the development of a single site specific correlation model is not sufficient, due to frequent and substantial variations of the (waste) water composition.In order to assess the total uncertainty of in situ spectrometry, a comprehensive lab test was carried out. It includes a detailed investigation of the uncertainty of CODreference methods (DIN and small tube tests), a precision analysis of the absorption spectra and the impact of those two factors on the total uncertainty of the COD(EQ) correlation model.


Subject(s)
Spectrophotometry, Ultraviolet/methods , Water Pollutants, Chemical/analysis , Environmental Monitoring/methods , Spectrophotometry, Ultraviolet/instrumentation , Uncertainty
12.
Water Sci Technol ; 57(10): 1667-73, 2008.
Article in English | MEDLINE | ID: mdl-18520026

ABSTRACT

Turbidity monitoring is a valuable tool for operating sewer systems, but it is often considered as a somewhat tricky parameter for assessing water quality, because measured values depend on the model of sensor, and even on the operator. This paper details the main components of the uncertainty in turbidity measurements with a special focus on reproducibility, and provides guidelines for improving the reproducibility of measurements in wastewater relying on proper calibration procedures. Calibration appears to be the main source of uncertainties, and proper procedures must account for uncertainties in standard solutions as well as non linearity of the calibration curve. With such procedures, uncertainty and reproducibility of field measurement can be kept lower than 5% or 25 FAU. On the other hand, reproducibility has no meaning if different measuring principles (attenuation vs. nephelometry) or very different wavelengths are used.


Subject(s)
Waste Disposal, Fluid/methods , Calibration , Environmental Monitoring/methods , Nephelometry and Turbidimetry , Reproducibility of Results , Uncertainty
13.
Water Sci Technol ; 57(9): 1389-96, 2008.
Article in English | MEDLINE | ID: mdl-18496004

ABSTRACT

Field experiments were carried out to contribute to the assessment of the VICAS protocol aiming to measure settling velocities of particles. Samples of deposited sediments have been taken in the Django Reinhardt stormwater detention and settling tank in Chassieu, France, using sediment traps located on the tank bottom. The first set of experiments was designed to assess the VICAS protocol in terms of mass balance and repeatability. A bias in the measurement of settling velocities distributions of deposited sediments (i.e. particles with high settling velocities) was suspected and confirmed by specific tests. Uncertainties in the final distribution curves have been evaluated by using Monte Carlo simulations and the law of propagation of uncertainties. All uncertainty calculations were implemented in a MatLab code named UVICAS used for each experiment. This code allows analysing the main sources of uncertainties and their evolution during experiments. Uncertainties in the final distribution curves decrease with increasing values of settling velocities and are lower than 1%.


Subject(s)
Environmental Monitoring/methods , Particulate Matter/chemistry , Water Movements , Water Pollutants/chemistry , Cities , Monte Carlo Method , Particle Size , Uncertainty
14.
Water Sci Technol ; 57(4): 581-8, 2008.
Article in English | MEDLINE | ID: mdl-18359999

ABSTRACT

Recent UV-visible spectrometers deliver on line and in situ absorbance spectra in wastewater or stormwater transported in urban drainage systems. After calibration with local data sets, spectra can be used to estimate pollutant concentrations. Calibration methods are usually based on PLS (Partial Least Squares) regression. Their most important difficulty lies in the identification of the number of both i) the latent vectors and ii) the independent variables. A method is proposed to identify these variables, based on an exhaustive tests procedure (Jackknife cross validation and matrix of prediction indicator). It was applied to estimate TSS (total suspended solids) or COD (chemical oxygen demand) concentrations at the inlet of a storage-settling tank in a stormwater separate sewer system, and compared to three other calibration methods used either for turbidity meters or UV-visible spectrometers. With the available calibration data set: i) the spectrometer gives results with better prediction quality than the turbidity meter, ii) for the spectrometer, local calibration gives better results than global calibration, iii) the proposed PLS method gives results with a similar order of magnitude in uncertainties as the manufacturer local calibration method, but is more open and transparent for the user. Similar results were obtained for a second data set.


Subject(s)
Drainage, Sanitary , Online Systems , Sewage/analysis , Water Pollutants/analysis , Calibration , Least-Squares Analysis , Nephelometry and Turbidimetry , Oxygen , Spectrophotometry, Ultraviolet
15.
Mol Pharmacol ; 73(3): 977-86, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18089837

ABSTRACT

KCNQ2 (Kv7.2) and KCNQ3 (Kv7.3) are voltage-gated K(+) channel subunits that underlie the neuronal M current. In humans, mutations in these genes lead to a rare form of neonatal epilepsy (Biervert et al., 1998; Singh et al., 1998), suggesting that KCNQ2/Q3 channels may be attractive targets for novel antiepileptic drugs. In the present study, we have identified the compound N-(6-chloro-pyridin-3-yl)-3,4-difluoro-benzamide (ICA-27243) as a selective activator of the neuronal M current and KCNQ2/Q3 channels. In SH-SY5Y human neuroblastoma cells, ICA-27243 produced membrane potential hyperpolarization that could be prevented by coadministration with the M-current inhibitors 10,10-bis(4-pyridinylmethyl)-9(10H)-anthracenone dihydrochloride (XE-991) and linopirdine. ICA-27243 enhanced both (86)Rb(+) efflux (EC(50) = 0.2 microM) and whole-cell currents in Chinese hamster ovary cells stably expressing heteromultimeric KCNQ2/Q3 channels (EC(50) = 0.4 microM). Activation of KCNQ2/Q3 channels was associated with a hyperpolarizing shift of the voltage dependence of channel activation (V((1/2)) shift of -19 mV at 10 microM). In contrast, ICA-27243 was less effective at activating KCNQ4 and KCNQ3/Q5 and was selective over a wide range of neurotransmitter receptors and ion channels such as voltage-dependent sodium channels and GABA-gated chloride channels. ICA-27243 (1-10 microM) was found to reversibly suppress seizure-like activity in an ex vivo hippocampal slice model of epilepsy and demonstrated in vivo anticonvulsant activity (ED(50) = 8.4 mg/kg) in the mouse maximal electroshock epilepsy model. In conclusion, ICA-27243 represents the first member of a novel chemical class of selective KCNQ2/Q3 activators with anticonvulsant-like activity in experimental models of epilepsy.


Subject(s)
Benzamides/pharmacology , KCNQ2 Potassium Channel/drug effects , KCNQ3 Potassium Channel/drug effects , Pyridines/pharmacology , Animals , CHO Cells , Cell Culture Techniques , Cell Line , Cell Line, Tumor , Cricetinae , Cricetulus , Dose-Response Relationship, Drug , Electrophysiology , Hippocampus/metabolism , Humans , Inhibitory Concentration 50 , Kidney/cytology , Male , Membrane Potentials/drug effects , Microelectrodes , Neuroblastoma/pathology , Patch-Clamp Techniques , Plasmids , RNA, Messenger/analysis , Rats , Rats, Sprague-Dawley , Sensitivity and Specificity
16.
Water Sci Technol ; 56(11): 17-25, 2007.
Article in English | MEDLINE | ID: mdl-18057637

ABSTRACT

A comprehensive investigation of the uncertainty of different COD analysis methods (DIN, small tube tests (STT) and UV-visible spectrometry methods) has been carried out on potassium hydrogen phthalate standard solutions and raw sewage samples from a large wastewater treatment plant. The UV-visible method allows estimating COD equivalent concentration from the measured absorption spectra by means of site specific regression and correlation functions. CODdin and CODstt methods showed equivalent global results but specific calibration relationships are necessary when high accuracy is required. The CODstt method is suitable for immediate COD analysis in the field. Sub-sampling is the main source of uncertainty. Spectrometry is able to estimate CODeq with an uncertainty of the same order of magnitude as the uncertainty in CODdin.


Subject(s)
Oxygen/chemistry , Sewage/analysis , Clinical Laboratory Techniques , Spectrophotometry, Ultraviolet , Uncertainty
17.
Cell Mol Life Sci ; 64(7-8): 989-98, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17372675

ABSTRACT

The suppression of hypoxia-induced erythropoietin (EPO) expression by inflammatory cytokines like interleukin-1 (IL-1) contributes to the development of the anemia of chronic disease (ACD). However, the precise mechanism of this suppression is unclear. The 3'-EPO enhancer mediates the transcriptional response to hypoxia by binding several transcription factors, including hypoxia-inducible factor, hepatocyte nuclear factor-4alpha (HNF-4alpha) and chicken ovalbumin upstream promoter transcription factor. We investigated whether IL-1beta inhibits the activity of the 3'-EPO enhancer via HNF-4alpha. IL-1beta inhibited HNF-4alpha mRNA expression and caused proteasome-dependent degradation of HNF-4alpha protein, which resulted in a strongly reduced DNA-binding activity of HNF-4alpha. Reporter gene assays revealed that IL-1beta caused a complete suppression of the hypoxic inducibility of the 3' enhancer via inhibition of HNF-4alpha. We conclude that IL-1beta, at least partially, reduces hypoxia-induced EPO expression by down-regulation of HNF-4alpha.


Subject(s)
Anemia/metabolism , Cell Hypoxia , Enhancer Elements, Genetic , Erythropoietin/genetics , Gene Expression Regulation/drug effects , Hepatocyte Nuclear Factor 4/metabolism , Interleukin-1beta/pharmacology , Anemia/genetics , Binding Sites , Cell Line, Tumor , DNA/metabolism , Hepatocyte Nuclear Factor 4/genetics , Humans , Hypoxia-Inducible Factor 1, alpha Subunit/metabolism , Leupeptins/pharmacology , Luminescent Proteins/genetics , Proteasome Endopeptidase Complex/metabolism , Proteasome Inhibitors , RNA, Messenger/metabolism , Recombinant Fusion Proteins/genetics
18.
Surg Endosc ; 21(6): 925-8, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17242988

ABSTRACT

BACKGROUND: Laparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described. METHODS: To assess the forces acting on a single tack, a mathematical model of the ventral hernia was created. The force was described in reference to the surface of the hernia orifice and the pressure in the abdominal cavity. The following different types of mesh were examined in vitro: Proceed (knitted mesh), Dual Mesh (expanded polytetrafluoroethylene [ePTFE] flat mesh), and Shelhigh (biologic flat mesh). The following different tacks also were examined: Protac, Anchor, and EMS. A pig model was used to measure the forces needed to destroy the connection between mesh and tissue and to describe the place of destruction (mesh, tissue, or tack) and the force needed. RESULTS: The force acting on a single tack proportionally depends on the surface of the hernia orifice and the pressure in the abdominal cavity. The force needed to disconnect the tissue and mesh reached 8.97 +/- 0.11 N for ProTac, 2.67 +/- 0.22 N for Anchor, and 6.67 +/- 1.32 N for EMS. These values do not allow the mesh to be held in the right position when the orifice exceeds 10 cm for Protac and EMS. The disconnection of the EMS and Protac junction damages the tissue. Anchor tacks are insufficient to hold the mesh and stay in the tissue CONCLUSIONS: In the case of small hernias (diameter<10 cm) EMS or ProTac used alone are not enough to hold the mesh. Anchor is not recommended alone in any hernia.


Subject(s)
Hernia, Ventral/surgery , Laparoscopy , Surgical Mesh , Sutures , Animals , Biomechanical Phenomena , Models, Animal , Models, Biological , Swine
19.
Water Sci Technol ; 54(6-7): 109-17, 2006.
Article in English | MEDLINE | ID: mdl-17120640

ABSTRACT

This paper presents continuous field experiments carried out during 4 years in a man-entry egg-shaped combined sewer in Lyon, France in order to contribute to the knowledge and the modelling of sediment accumulation and sediment removal by means of a Hydrass flushing gate. The 250 microm sediments are mainly mineral, and their physical and chemical characteristics appear as rather stable in time and space. Long-term sediment monitoring reveals: (i) a regular asymptotic increase of both the sediment mass and the slope of its longitudinal profile, (ii) a clear correlation between local sediment profile irregularities and sewer ancillaries but without significant influence on the global and long term accumulation. Simple sediment accumulation modelling shows: (i) a good suitability of a three parameters conceptual model to reproduce asymptotic sediment volume accumulation, and (ii) a good suitability of the Velikanov model to reproduce sediment profiles. Both models reproduce observations with an acceptable margin of uncertainty for operational management purposes but are very sensitive to input data and parameter values. The Hydrass flushing gate is efficient and it appeared that the mass of sediments moves downstream linearly with the number of flushes.


Subject(s)
Drainage, Sanitary , Sewage , Waste Disposal, Fluid/instrumentation , Facility Design and Construction , Models, Theoretical , Research Design , Waste Disposal, Fluid/methods , Water Movements
20.
Water Sci Technol ; 54(6-7): 231-8, 2006.
Article in English | MEDLINE | ID: mdl-17120654

ABSTRACT

Stormwater quality simulation models are useful tools for the design and management of sewer systems. Modelling results are highly sensitive to experimental data used for calibration. This sensitivity is examined for three modelling approaches of various complexities (site mean concentration approach, event mean concentration approach and build-up, washoff and transport modelling approach) applied to a typical case study (design of a dry detention tank), accounting for the variability of calibration data and their effect on simulation results. Calibrated models with different calibration data sets were used to simulate 3 years of rainfall with different retention tank specific volumes. Annual pollutant load interception efficiencies were determined. Simulations results revealed (i) that there is no advantage in using the EMC model compared to the SMC model and (ii) that the BWT model resulted in higher design ratios than those given by the SMC/hydraulic approach. For both EMC and BWT models, using an increasing number n of events for calibration leads to narrower confidence intervals for the design ratios. It is crucial for design ratios to account for successive storm events in chronological order and to account for the maximum allowable flow to be transferred to the downstream WWTP.


Subject(s)
Models, Theoretical , Rain , Sewage , Waste Disposal, Fluid/instrumentation , Computer Simulation
SELECTION OF CITATIONS
SEARCH DETAIL
...