Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Ophthalmol ; 132(6): 903-9, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11730656

ABSTRACT

PURPOSE: To report a computerized method for determining visual acuity in children using the Amblyopia Treatment Study visual acuity testing protocol. METHODS: A computerized visual acuity tester was developed that uses a programmed handheld device that uses the Palm operating system (Palm, Inc, Santa Clara, California). The handheld device communicates with a personal computer running a Linux operating system and 17-inch monitor. At a test distance of 3 m, single letters can be displayed from 20/800 to 20/12. A C program on the handheld device runs the Amblyopia Treatment Study visual acuity testing protocol. Using this method, visual acuity was tested in both the right and left eyes, and then the testing was repeated in 156 children age 3 to 7 years at four clinical sites. RESULTS: Test-retest reliability was high (r =.92 and 0.95 for and right and left eyes, respectively), with 88% of right eye retests and 94% of left eye retests within 0.1 logarithm of minimal angle of resolution (logMAR) units of the initial test. The 95% confidence interval for an acuity score was calculated to be the score +/- 0.13 logMAR units. For a change between two acuity scores, the 95% confidence interval was the difference +/- 0.19 logMAR units. CONCLUSIONS: We have developed a computerized method for measurement of visual acuity. Automation of the Amblyopia Treatment Study visual acuity testing protocol is an effective method of testing visual acuity in children 3 to 7 years of age.


Subject(s)
Vision Tests/methods , Visual Acuity , Amblyopia/diagnosis , Amblyopia/therapy , Child , Child, Preschool , Clinical Protocols , Computers , Female , Humans , Male , Reproducibility of Results , Vision Tests/instrumentation
2.
Arch Ophthalmol ; 119(9): 1345-53, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11545641

ABSTRACT

OBJECTIVE: To evaluate the reliability of a new visual acuity testing protocol for children using isolated surrounded HOTV optotypes. METHODS: After initial pilot testing and modification, the protocol was evaluated using the Baylor-Video Acuity Tester (BVAT) to present isolated surrounded HOTV optotypes. At 6 sites, the protocol was evaluated for testability in 178 children aged 2 to 7 years and for reliability in a subset of 88 children. Twenty-eight percent of the 178 children were classified as having amblyopia. RESULTS: Using the modified protocol, testability ranged from 24% in 2-year-olds to 96% in 5- to 7-year-olds. Test-retest reliability was high (r = 0.82), with 93% of retest scores within 0.1 logMAR unit of the initial test score. The 95% confidence interval for an acuity score was calculated to be the score +/-0.125 logMAR unit. For a change between 2 acuity scores, the 95% confidence interval was the difference +/-0.18 logMAR unit. CONCLUSIONS: The visual acuity protocol had a high level of testability in 3- to 7-year-olds and excellent test-retest reliability. The protocol has been incorporated into the multicenter Amblyopia Treatment Study and has wide potential application for standardizing visual acuity testing in children.


Subject(s)
Amblyopia/therapy , Vision Tests/methods , Visual Acuity/physiology , Amblyopia/physiopathology , Atropine/therapeutic use , Child , Child, Preschool , Humans , Mydriatics/therapeutic use , Reproducibility of Results , Sensory Deprivation
3.
J AAPOS ; 5(4): 250-4, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11507585

ABSTRACT

OBJECTIVE: To develop a questionnaire to assess the acceptability of amblyopia treatment and its effect on the child and family. METHODS: A 20-item parental survey was developed and pilot tested on 64 subjects, aged 3 to 6 years, participating in the Amblyopia Treatment Study, a randomized trial comparing patching and atropine as treatments for moderate amblyopia. The survey was administered after 4 weeks of treatment. A descriptive item analysis and an internal consistency reliability analysis were performed. RESULTS: Nineteen of the 20 items demonstrated adequate variability as evidenced by the frequency distributions for item responses. Only 4 (<1%) of 1280 possible item responses were missing, one each by 4 different respondents. Factor analysis identified 3 treatment-related factors--"adverse effects," "compliance," and "social stigma"--among 11 of the 20 items. The internal-consistency reliability alpha for the 5-item adverse effects subscale was 0.82, the 4-item compliance subscale alpha was 0.81, and the 2-item social stigma subscale alpha was 0.84. CONCLUSIONS: The Amblyopia Treatment Index appears to be a useful instrument for assessing the impact of amblyopia treatment in 3- to 6-year-old children.


Subject(s)
Amblyopia/therapy , Atropine/therapeutic use , Health Status Indicators , Mydriatics/therapeutic use , Sensory Deprivation , Amblyopia/physiopathology , Child , Child, Preschool , Female , Humans , Male , Patient Compliance , Pilot Projects , Reproducibility of Results , Surveys and Questionnaires , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...