Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Arch Orthop Trauma Surg ; 144(3): 1297-1302, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38172435

ABSTRACT

INTRODUCTION: Osteochondrosis dissecans (OCD) at the capitellum is a common pathology in young patients. Although arthroscopic interventions are commonly used, there is a lack of information about the accessibility of the defects during elbow arthroscopy by using standard portals. MATERIALS AND METHODS: An elbow arthroscopy using the standard portals was performed in seven fresh frozen specimens. At the capitellum, the most posterior and anterior cartilage surface reachable was marked with K-wires. Using a newly described measuring method, we constructed a circular sector around the rotational center of the capitellum. The intersection of K-wire "A" and "B" with the circular sector was marked, and the angles between the K-wires and the Rogers line, alpha angle for K-Wire "A" and beta angle for K-wire "B", and the corridor not accessible during arthroscopy was digitally measured. RESULTS: On average, we found an alpha angle of 53° and a beta angle of 104°. Leaving a sector of 51° which was not accessible via the standard portals during elbow arthroscopy. CONCLUSION: Non-accessible capitellar lesions during elbow arthroscopy should be considered preoperatively, and the informed consent discussion should always include the possibility of open procedures or the use of flexible instruments.


Subject(s)
Elbow Joint , Osteochondritis Dissecans , Humans , Arthroscopy/methods , Elbow , Elbow Joint/surgery , Osteochondritis Dissecans/surgery , Bone Wires
2.
Unfallchirurgie (Heidelb) ; 125(9): 699-708, 2022 Sep.
Article in German | MEDLINE | ID: mdl-35833974

ABSTRACT

Good to very good clinical results can be achieved in older patients with the implantation of a total elbow prosthesis in cases of distal humeral fractures by taking the morphological features of the fractures, the bone quality as well as the individual patient requirements and variables into account. The most commonly used design is the cemented semiconstrained linked total elbow endoprosthesis. The unlinked prosthesis design and hemiarthroplasty require intact or adequately reconstructable musculoligamentous structures or condyles and a preserved or replaced radial head. The recommended weight limit after total elbow prosthesis as well as potential intraoperative and postoperative complications must be considered and discussed with the patients. A secondary total elbow arthroplasty is also possible after primary conservative treatment approaches, e.g., in the case of contraindicated surgery in the fracture situation, persistent pain and functional restrictions. This article provides an overview of the technique and the appropriate indications.


Subject(s)
Arthroplasty, Replacement, Elbow , Elbow Joint , Elbow Prosthesis , Humeral Fractures , Aged , Arthroplasty, Replacement, Elbow/methods , Elbow Joint/diagnostic imaging , Humans , Humeral Fractures/diagnostic imaging , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...