Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
2.
Sensors (Basel) ; 24(5)2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38474964

ABSTRACT

Effective early fire detection is crucial for preventing damage to people and buildings, especially in fire-prone historic structures. However, due to the infrequent occurrence of fire events throughout a building's lifespan, real-world data for training models are often sparse. In this study, we applied feature representation transfer and instance transfer in the context of early fire detection using multi-sensor nodes. The goal was to investigate whether training data from a small-scale setup (source domain) can be used to identify various incipient fire scenarios in their early stages within a full-scale test room (target domain). In a first step, we employed Linear Discriminant Analysis (LDA) to create a new feature space solely based on the source domain data and predicted four different fire types (smoldering wood, smoldering cotton, smoldering cable and candle fire) in the target domain with a classification rate up to 69% and a Cohen's Kappa of 0.58. Notably, lower classification performance was observed for sensor node positions close to the wall in the full-scale test room. In a second experiment, we applied the TrAdaBoost algorithm as a common instance transfer technique to adapt the model to the target domain, assuming that sparse information from the target domain is available. Boosting the data from 1% to 30% was utilized for individual sensor node positions in the target domain to adapt the model to the target domain. We found that additional boosting improved the classification performance (average classification rate of 73% and an average Cohen's Kappa of 0.63). However, it was noted that excessively boosting the data could lead to overfitting to a specific sensor node position in the target domain, resulting in a reduction in the overall classification performance.

3.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 17.
Article in English | MEDLINE | ID: mdl-37998524

ABSTRACT

Background: Sex-specific differences in heart disease outcomes are influenced by the levels of the steroid hormones, estrogen and testosterone. While the roles of estrogen receptors in cardiac disease are well-studied in animals and humans, respective research on androgen receptors (AR) is limited. Here we investigate AR protein and mRNA expression in human myocardium of various cardiac diseases. Methods: AR expression was analyzed by western blotting in myocardium from human non-failing hearts (NF, n = 6) and patients with aortic stenosis (AS, n = 6), hypertrophic cardiomyopathy (HCM, n = 7), dilated cardiomyopathy (DCM, n = 7), and ischemic cardiomyopathy (ICM, n = 7). Using an AR45-specific antibody, a subsequent western blot assessed samples from male and female patients with HCM (n = 10) and DCM (n = 10). The same sample set was probed for full-length AR and AR45 mRNA expression. Immunohistochemistry (IHC) localized AR in myocardium from HCM and AS hearts. Results: Full-length AR was notably enriched in AS and HCM hearts compared to ICM, DCM, and NF. Similarly, AR45 was more abundant in HCM than in DCM. In contrast to the pattern observed for AR protein, full-length AR mRNA levels were lower in HCM compared to DCM, with no discernible difference for the AR45 isoform. Although gender differences in AR expression were not detected in western blots or qRT-PCR, IHC showed stronger nuclear AR signals in males than in females. Conclusions: Our findings indicate disease-specific regulation of AR mRNA and/or AR protein in cardiac hypertrophy, underscoring a potential role in this cardiac pathology.

4.
Europace ; 25(10)2023 10 05.
Article in English | MEDLINE | ID: mdl-37906433

ABSTRACT

AIMS: State-of-the-art pacemaker implantation technique in infants and small children consists of pace/sense electrodes attached to the epicardium and a pulse generator in the abdominal wall with a significant rate of dysfunction during growth, mostly attributable to lead failure. In order to overcome lead-related problems, feasibility of epicardial implantation of a leadless pacemaker at the left ventricular apex in a growing animal model was studied. METHODS AND RESULTS: Ten lambs (median body weight 26.8 kg) underwent epicardial implantation of a Micra transcatheter pacing system (TPS) pacemaker (Medtronic Inc., Minneapolis, USA). Using a subxyphoid access, the Micra was introduced through a short, thick-walled tube to increase tissue contact and to prevent tilting from the epicardial surface. The Micra's proprietary delivery system was firmly pressed against the heart, while the Micra was pushed forward out of the sheath allowing the tines to stick into the left ventricular apical epimyocardium. Pacemakers were programmed to VVI 30/min mode. Pacemaker function and integrity was followed for 4 months after implantation. After implantation, median intrinsic R-wave amplitude was 5 mV [interquartile range (IQR) 2.8-7.5], and median pacing impedance was 2235 Ω (IQR 1725-2500), while the median pacing threshold was 2.13 V (IQR 1.25-2.9) at 0.24 ms. During follow-up, 6/10 animals had a significant increase in pacing threshold with loss of capture at maximum output at 0.24 ms in 2/10 animals. After 4 months, median R-wave amplitude had dropped to 2.25 mV (IQR 1.2-3.6), median pacing impedance had decreased to 595 Ω (IQR 575-645), and median pacing threshold had increased to 3.3 V (IQR 1.8-4.5) at 0.24 ms. Explantation of one device revealed deep penetration of the Micra device into the myocardium. CONCLUSION: Short-term results after epicardial implantation of the Micra TPS at the left ventricular apex in lambs were satisfying. During mid-term follow-up, however, pacing thresholds increased, resulting in loss of capture in 2/10 animals. Penetration of one device into the myocardium was of concern. The concept of epicardial leadless pacing seems very attractive, and the current shape of the Micra TPS makes the device unsuitable for epicardial placement in growing organisms.


Subject(s)
Pacemaker, Artificial , Humans , Child , Animals , Sheep , Treatment Outcome , Equipment Design , Heart Ventricles , Myocardium , Cardiac Pacing, Artificial/methods
5.
Circulation ; 148(25): 2029-2037, 2023 12 19.
Article in English | MEDLINE | ID: mdl-37886885

ABSTRACT

BACKGROUND: In severely affected patients with catecholaminergic polymorphic ventricular tachycardia, beta-blockers are often insufficiently protective. The purpose of this study was to evaluate whether flecainide is associated with a lower incidence of arrhythmic events (AEs) when added to beta-blockers in a large cohort of patients with catecholaminergic polymorphic ventricular tachycardia. METHODS: From 2 international registries, this multicenter case cross-over study included patients with a clinical or genetic diagnosis of catecholaminergic polymorphic ventricular tachycardia in whom flecainide was added to beta-blocker therapy. The study period was defined as the period in which background therapy (ie, beta-blocker type [beta1-selective or nonselective]), left cardiac sympathetic denervation, and implantable cardioverter defibrillator treatment status, remained unchanged within individual patients and was divided into pre-flecainide and on-flecainide periods. The primary end point was AEs, defined as sudden cardiac death, sudden cardiac arrest, appropriate implantable cardioverter defibrillator shock, and arrhythmic syncope. The association of flecainide with AE rates was assessed using a generalized linear mixed model assuming negative binomial distribution and random effects for patients. RESULTS: A total of 247 patients (123 [50%] females; median age at start of flecainide, 18 years [interquartile range, 14-29]; median flecainide dose, 2.2 mg/kg per day [interquartile range, 1.7-3.1]) were included. At baseline, all patients used a beta-blocker, 70 (28%) had an implantable cardioverter defibrillator, and 21 (9%) had a left cardiac sympathetic denervation. During a median pre-flecainide follow-up of 2.1 years (interquartile range, 0.4-7.2), 41 patients (17%) experienced 58 AEs (annual event rate, 5.6%). During a median on-flecainide follow-up of 2.9 years (interquartile range, 1.0-6.0), 23 patients (9%) experienced 38 AEs (annual event rate, 4.0%). There were significantly fewer AEs after initiation of flecainide (incidence rate ratio, 0.55 [95% CI, 0.38-0.83]; P=0.007). Among patients who were symptomatic before diagnosis or during the pre-flecainide period (n=167), flecainide was associated with significantly fewer AEs (incidence rate ratio, 0.49 [95% CI, 0.31-0.77]; P=0.002). Among patients with ≥1 AE on beta-blocker therapy (n=41), adding flecainide was also associated with significantly fewer AEs (incidence rate ratio, 0.25 [95% CI, 0.14-0.45]; P<0.001). CONCLUSIONS: For patients with catecholaminergic polymorphic ventricular tachycardia, adding flecainide to beta-blocker therapy was associated with a lower incidence of AEs in the overall cohort, in symptomatic patients, and particularly in patients with breakthrough AEs while on beta-blocker therapy.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Female , Humans , Adolescent , Male , Flecainide/adverse effects , Incidence , Cross-Over Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/epidemiology , Adrenergic beta-Antagonists/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control
6.
Europace ; 25(8)2023 08 25.
Article in English | MEDLINE | ID: mdl-37622573

ABSTRACT

This review article reflects how publications in EP Europace have contributed to advancing the science of management of arrhythmic disease in children and adult patients with congenital heart disease within the last 25 years. A special focus is directed to congenital atrioventricular (AV) block, the use of pacemakers, cardiac resynchronization therapy devices, and implantable cardioverter defibrillators in the young with and without congenital heart disease, Wolff-Parkinson-White syndrome, mapping and ablation technology, and understanding of cardiac genomics to untangle arrhythmic sudden death in the young.


Subject(s)
Heart Defects, Congenital , Wolff-Parkinson-White Syndrome , Adult , Humans , Child , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Heart , Cardiac Resynchronization Therapy Devices , Death, Sudden
7.
RSC Adv ; 13(30): 20761-20779, 2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37435378

ABSTRACT

For a comprehensive safety assessment of stationary lithium-ion-battery applications, it is necessary to better understand the consequences of thermal runaway (TR). In this study, experimental tests comprising twelve TR experiments including four single-cell tests, two cell stack tests and six second-life module tests (2.65 kW h and 6.85 kW h) with an NMC-cathode under similar initial conditions were conducted. The temperature (direct at cells/modules and in near field), mass loss, cell/module voltage, and qualitative vent gas composition (Fourier transform infrared (FTIR) and diode laser spectroscopy (DLS) for HF) were measured. The results of the tests showed that the battery TR is accompanied by severe and in some cases violent chemical reactions. In most cases, TR was not accompanied by pre-gassing of the modules. Jet flames up to a length of 5 m and fragment throwing to distances to more than 30 m were detected. The TR of the tested modules was accompanied by significant mass loss of up to 82%. The maximum HF concentration measured was 76 ppm, whereby the measured HF concentrations in the module tests were not necessarily higher than that in the cell stack tests. Subsequently, an explosion of the released vent gas occurred in one of the tests, resulting in the intensification of the negative consequences. According to the evaluation of the gas measurements with regard to toxicity base on the "Acute Exposure Guideline Levels" (AEGL), there is some concern with regards to CO, which may be equally as important to consider as the release of HF.

8.
Pediatr Cardiol ; 44(8): 1746-1753, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37505269

ABSTRACT

Patients with dextro transposition of the great arteries (d-TGA) after atrial switch procedure are at risk to develop heart failure and arrhythmias during long-term follow-up. The present study aims to add knowledge on the fate of subjects after Mustard procedure during long-term follow-up into adulthood. A single center, retrospective chart review analysis was conducted. All subjects who had Mustard-type atrial switch procedure between 1969 and 1994 at our institution were included. A total of 92 subjects were included. Early postoperative death was reported in 2 subjects. Long-term follow-up was available in 49 survivors. Of those, 6 individuals died during further follow-up. Sudden cardiac death was the most prevalent cause for fatal outcome. Mortality during long-term follow-up was associated with the presence of additional cardiovascular malformations (complex d-TGA). Sinus node dysfunction was observed in 65% of the patients and atrial tachyarrhythmias were common in adult survivors (63%). Implantation of a pacemaker or a cardioverter defibrillator was required in 31% and 45% of those surviving into adulthood. Complications were frequently observed during follow-up after either pacemaker or cardioverter defibrillator implantation (43%) with lead failure being the most frequent complication. The aging population of patients after Mustard procedure is facing challenging problems mainly resulting from a failing systemic right ventricle, presence of associated cardiac malformations and the presence of atrial baffles associated with relevant atrial scars. Age, associated cardiac malformations, and atrial tachyarrhythmias seem to play a major role in determining the fate of patients with d-TGA after atrial switch procedures.


Subject(s)
Arterial Switch Operation , Atrial Fibrillation , Transposition of Great Vessels , Adult , Humans , Aged , Arterial Switch Operation/adverse effects , Transposition of Great Vessels/surgery , Retrospective Studies , Atrial Fibrillation/complications , Tachycardia/complications , Arteries , Follow-Up Studies
10.
Heart Rhythm ; 20(6): 891-899, 2023 06.
Article in English | MEDLINE | ID: mdl-36898470

ABSTRACT

BACKGROUND: Accessory atrioventricular pathways (APs) are the most common tachycardia substrate for supraventricular tachycardia (SVT) in the young. Endocardial catheter ablation of AP may be unsuccessful in up to 5% of patients because of a coronary sinus location. OBJECTIVE: The purpose of this study was to obtain data on ablation of accessory pathways within the coronary venous system (CVS) in the young. METHODS: Analysis of feasibility, outcome, and safety in patients ≤18 years with coronary sinus accessory pathways (CS-APs) and catheter ablation via CVS in a tertiary pediatric electrophysiological referral center (May 2003 to December 2021) was performed. The control group adjusted for age, weight, and pathway location was established from patients of the prospective European Multicenter Pediatric Ablation Registry who all had undergone endocardial AP ablation. RESULTS: Twenty-four individuals underwent mapping and intended AP ablation within the CVS (age 2.7-17.3 years; body weight 15.0-72.0 kg). Because of proximity to the coronary artery, ablation was withheld in 2 of the patients. Overall procedural success was achieved in 20 of 22 study patients (90.9%) and in 46 of 48 controls (95.8%). Coronary artery injury after radiofrequency ablation was noted in 2 of 22 study patients (9%) and in 1 of 48 controls (2%). In CVS patients, repeat SVT occurred in 5 of 22 patients (23%) during median follow-up of 8.5 years, and 4 of the 5 underwent reablation, resulting in 94.4% overall success. Controls were free from SVT during follow-up of 12 months as defined by the registry protocol. CONCLUSION: Success of CS-AP ablation in the young was comparable to that of endocardial AP ablation. Substantial risk of coronary artery injury should be considered when CS-AP ablation is performed in the young.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Coronary Sinus , Tachycardia, Supraventricular , Humans , Child , Child, Preschool , Adolescent , Accessory Atrioventricular Bundle/surgery , Coronary Sinus/surgery , Prospective Studies , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/surgery , Tachycardia, Supraventricular/etiology , Catheter Ablation/methods
11.
Eur Heart J Case Rep ; 7(2): ytad052, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36845833

ABSTRACT

Background: Dilated cardiomyopathy (DCM) is a leading cause of heart transplantation (HTx) in children. Surgical pulmonary artery banding (PAB) is used worldwide to achieve functional heart regeneration and remodelling. Case summary: We report for the first-time successful bilateral transcatheter implantation of bilateral pulmonary artery flow restrictors in a case series of three infants with severe DCM based on left-ventricular non-compaction morphology associated with Barth syndrome in one and a non-classified syndrome in another. Functional cardiac regeneration was observed in two patients after almost 6 months of endoluminal banding, and in the neonate with Barth syndrome already after 6 weeks. Accompanied by an improvement in functional class (Class IV to Class I), the left ventricular end-diastolic dimensions z-score normalized, as did the elevated serum brain natriuretic peptide levels. A listing for HTx could be avoided. Discussion: Percutaneous bilateral endoluminal PAB is a novel minimally invasive approach that enables functional cardiac regeneration in infants with severe DCM and preserved right ventricular function. Interruption of the ventriculo-ventricular interaction, the key mechanism for recovery, is avoided. Intensive care for these critically ill patients is reduced to a minimum. However, investing in 'heart regeneration to avoid transplantation' remains a challenge.

12.
Bioresour Technol ; 361: 127734, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35932945

ABSTRACT

Biomass gasification is recognized as a viable avenue to accelerate the sustainable production of hydrogen. In this work, a numerical simulation model of air gasification of rice husks is developed using the Aspen Plus to investigate the feasibility of producing hydrogen-rich syngas. The model is experimentally validated with rice husk gasification results and other published studies. The influence of temperature and equivalence ratio on the syngas composition, H2 yield, LHVSyngas, H2/CO ratio, CGE, and PCG was studied. Furthermore, the synchronized effects of temperature and ER are studied using RSM to determine the operational point of maximizing H2 yield and PCG. The RSM analysis results show optimum performance at temperatures between 820 °C and 1090 °C and ER in the range of 0.06-0.10. The findings show that optimal operating conditions of the gasification system can be achieved at a more refined precision through simulations coupled with advanced optimization techniques.


Subject(s)
Hydrogen , Oryza , Biomass , Temperature
13.
J Cardiovasc Electrophysiol ; 33(8): 1757-1766, 2022 08.
Article in English | MEDLINE | ID: mdl-35578015

ABSTRACT

INTRODUCTION: Catheter contact is a key determinant for lesion size in radiofrequency catheter ablation (RFA). Monitoring of contact force (CF) during RFA has been shown to improve efficacy of RFA in experimental settings as well as in adult patients. Coronary artery narrowing after RFA has been described in experimental settings as well as in children and adults and may be dependent from catheter contact. The value of CF monitoring concerning these issues has not been systematically studied yet. Value of high versus low CF during RFA in piglets was studied to assess lesion size and potential coronary artery involvement mimicking RFA in small children. METHODS: RFA with continuous CF monitoring was performed in 24 piglets (median weight 18.5 kg) using a 7 F TactiCath Quartz radiofrequency (RF) ablation catheter (Abbott). A total of 7 lesions were induced in each animal applying low (10-20 g) or high (40-60 g) CF. RF energy was delivered with a target temperature of 65°C at 30 W for 30 s. Coronary angiography was performed prior and immediately after RF application. Animals were assigned to repeat coronary angiography followed by heart removal after 48 h (n = 12) or 6 months (n = 12). Lesions with surrounding myocardium were excised, fixated, and stained. Lesion volumes were measured by microscopic planimetry. RESULTS: A total of 148 RF lesions were identified in the explanted hearts. Only in the subset of lesions at the AV annulus 6 month after ablation, lesion size and number of lesions exhibiting transmural extension were higher in the high CF group compared to low CF. In all other locations CF had no impact on lesion size and mural extension after 48 h as well as after 6 months. Additional parameters such as lesion size index and force time integral were also not related to lesion size. Coronary artery damage was present in two animals after 48 h and in one after 6 months and was not related to CF. CONCLUSION: In our experimental setting, lesion size in piglets was not related to catheter CF. Transmural extension of the RF lesions involving the layers of the coronary arteries was frequently noted irrespective of CF. Coronary artery narrowing was present in 3/24 animals and was not related to CF. In infants and toddlers, low CF (10-20 g) may be of adequate effect. Impact of CF monitoring during conventional RF ablation in children requires further investigation.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Animals , Catheter Ablation/adverse effects , Catheters , Heart , Humans , Myocardium/pathology
14.
J Interv Card Electrophysiol ; 65(2): 411-417, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35419671

ABSTRACT

BACKGROUND: Prevalence of atrial fibrillation (AF) is increasing in adult patients with congenital heart disease (CHD). Experience using the cryoballoon to achieve pulmonary vein isolation (PVI) in adult CHD patients is limited. The aim of the present study was to assess the value of PVI by cryoballoon in adult CHD patients and to evaluate the significance of additional radiofrequency (RF) ablation of atrial tachycardia (AT). PATIENTS AND METHODS: Prospective data analysis; all patients with CHD and AF and PVI using the cryoballoon from January 2017 through November 2021 were included. RESULTS: Nineteen patients with various types of CHD were included. Median age was 58 (IQR 47-63) years. A total of 12/19 (63%) patients had had RF ablation of right atrial AT before. Median procedure duration was 225 (IQR 196-261) min. Median fluoroscopy time was 12.3 (IQR 5.2-19.5) min and median freeze time was 32 (IQR 28-36.3) min. Procedural success was achieved in all patients. Additional RF catheter ablation of intraatrial reentrant tachycardia within the left atrium was performed in 3/19 (16%) subjects and within the right atrium in 6/19 (32%) patients. Median follow-up was 26 (IQR 9-49) months. Excluding a 90-day blanking period, recurrence of AF was observed in 6/19 subjects (32%). After one redo procedure deploying RF energy only, 84% of all patients remained free from recurrence. Phrenic nerve palsy was observed in 1 subject. CONCLUSION: Results after PVI using the cryoballoon plus additional RF ablation of AT were promising (84% success including one redo procedure). Success of AF ablation was unsatisfactory in all patients who had no additional AT ablation. Ablation of any AT in these patients should therefore be considered in addition to PVI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Heart Defects, Congenital , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Middle Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Cryosurgery/methods , Prospective Studies , Treatment Outcome , Catheter Ablation/methods , Pulmonary Veins/surgery , Tachycardia, Supraventricular/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Recurrence
16.
J Cardiovasc Electrophysiol ; 33(5): 943-952, 2022 05.
Article in English | MEDLINE | ID: mdl-35199408

ABSTRACT

INTRODUCTION: Atrial tachycardias (AT) in patients with congenital heart disease (CHD) are significantly contributing to morbidity and mortality. Aim of this study was to evaluate the long-term course of CHD patients requiring repeat ablation procedures (RAP) of AT. PATIENTS AND METHODS: All 144 patients with CHD who had undergone ablation of AT at our center between January 2003 and October 2018 were enrolled. Patients were classified according to the complexity of CHD: complex CHD (cCHD), moderate CHD (mCHD), and simple CHD (sCHD). RESULTS: A total of 101 RAP were performed in 64 patients. One RAP was performed in n = 40, two in n = 13, three in n = 10, and five in n = 1. Acute success rate was 82% (83/101) and was not associated with the complexity of CHD (p = 1.0). Number of procedures was lower in patients with sCHD than in patients with mCHD and cCHD (sCHD 1.3 ± 0.6, mCHD 1.8 ± 1.0, and cCHD 1.8 ± 1.1, p = .04). RAP were most frequent in patients after Fontan palliation or Atrial switch procedure (2.0 ± 1.1 [n = 41] vs. 1.6 ± 0.9 all others, p = .016) and in patients with multiple unstable AT's (2.5 ± 1.1 [n = 11] vs. 1.7 ± 1.0, p = .008). Major complications occurred in 4/101 procedures. Complete follow-up was available in 125 patients. Since last RAP 73% of the patients were in sinus/atrial rhythm and 34/125 patients (27%) with AT recurrence did not require re-ablation with mean follow-up of 52 ± 40 months. CONCLUSIONS: Recurrences after ablation of AT in CHD patients were frequent. After RAP promising long-term results could be achieved. Data encourage repetitive ablation procedures in this patient population.


Subject(s)
Ablation Techniques , Catheter Ablation , Fontan Procedure , Heart Defects, Congenital , Tachycardia, Supraventricular , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Defects, Congenital/complications , Heart Defects, Congenital/surgery , Humans , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/surgery , Treatment Outcome
18.
Herzschrittmacherther Elektrophysiol ; 32(2): 152-157, 2021 Jun.
Article in German | MEDLINE | ID: mdl-33825056

ABSTRACT

The normal fetal heart rate ranges between 110 und 180 beats per minute (bpm). Intrauterine arrhythmias are not an uncommon finding. Fetal echocardiography (ECG) allows for correct diagnosis of the arrhythmia, which is prerequisite for decision making and treatment. Most fetal rhythm disturbances are the result of premature atrial contractions and are of little clinical significance. Intrauterine bradycardias (heart rate < 110 bpm) result from sinus node dysfunction, complete AV block and nonconducted atrial bigeminy. Isolated complete heart block related to maternal anti-SSA/Ro or SSB/La auto-antibodies is irreversible in almost all fetuses. Anti-inflammatory therapy and chronotropic medication may improve outcome. Newborn babies often require pacemaker implantation to augment cardiac output. Intrauterine tachycardias (heart rate > 180 bpm) are most commonly related to supraventricular tachycardia and atrial flutter. Specific antiarrhythmic medication is available to stop the arrhythmia and to prevent hemodynamic deterioration.


Subject(s)
Fetal Diseases , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Bradycardia , Echocardiography , Electrocardiography , Female , Fetal Diseases/diagnosis , Humans , Infant, Newborn , Pregnancy
19.
Phys Rev Lett ; 126(3): 030603, 2021 Jan 22.
Article in English | MEDLINE | ID: mdl-33543943

ABSTRACT

We consider a disordered Hubbard model and show that, at sufficiently weak disorder, a single spin-down mobile impurity can thermalize an extensive initially localized system of spin-up particles. Thermalization is enabled by resonant processes that involve correlated hops of the impurity and localized particles. This effect indicates that Anderson localized insulators behave as "supercooled" systems, with mobile impurities acting as ergodic seeds. We provide analytical estimates, supported by numerical exact diagonalization, showing how the critical disorder strength for such mechanism depends on the particle density of the localized system. In the U→∞ limit, doublons are stable excitations, and they can thermalize mesoscopic systems by a similar mechanism. The emergence of an additional conservation law leads to an eventual localization of doublons. Our predictions apply to fermionic and bosonic systems and are readily accessible in ongoing experiments simulating synthetic quantum lattices with tunable disorder.

20.
Pediatr Cardiol ; 42(3): 685-691, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33454819

ABSTRACT

Transseptal puncture (TSP) is a standard procedure to obtain access to the left heart. However, data on TSP in infants and children particularly with congenital heart defects (CHD) is sparse. Safety and efficacy of TSP in infants and children < 18 years with normal cardiac anatomy and with CHD were assessed. 327 TSP were performed in a total of 300 individuals < 18 years from 10/2002 to 09/2018 in our tertiary pediatric referral center. Median age at TSP was 11.9 years (IQR 7.8-15; range: first day of life to 17.9 years). 13 subjects were < 1 year. Median body weight was 43.8 kg (IQR 26.9-60; range: 1.8-121 kg). CHD was present in 28/327 (8.6%) procedures. TSP could be successfully performed in 323/327 (98.8%) procedures and was abandoned in 4 procedures due to imminent or incurred complications. Major complications occurred in 4 patients. 3 of these 4 subjects were ≤ 1 year of age and required TSP for enlargement of a restrictive atrial septal defect in complex CHD. Two of these babies deceased within 48 h after TSP attempt. The third baby needed urgent surgery in the cath lab. Pericardial effusion requiring drainage was noted in the forth patient (> 1 year) who was discharged well later. Minor complications emerged in 5 patients. The youngest of these individuals (0.3 years, 5.8 kg) developed small pericardial effusion after anterograde ballon valvuloplasty for critical aortic stenosis. The remaining 4/5 patients developed small pericardial effusion after ablation of a left-sided accessory atrioventricular pathway (6.1-12.2 years, 15.6-34.0 kg). TSP for access to the left heart was safe and effective in children and adolescents > 1 year of age. However, TSP was a high-risk procedure in small infants with a restrictive interatrial septum with need for enlargement of interatrial communication.


Subject(s)
Atrial Septum/surgery , Cardiac Surgical Procedures/methods , Heart Defects, Congenital/surgery , Punctures/methods , Adolescent , Cardiac Surgical Procedures/adverse effects , Case-Control Studies , Child , Child, Preschool , Female , Heart Atria/surgery , Humans , Infant , Infant, Newborn , Male , Punctures/adverse effects , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...