Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Nat Commun ; 12(1): 5658, 2021 Sep 27.
Article in English | MEDLINE | ID: mdl-34580294

ABSTRACT

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10-4, with an over threefold improvement on the previous measurement.

2.
Med Image Anal ; 73: 102199, 2021 10.
Article in English | MEDLINE | ID: mdl-34365143

ABSTRACT

We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most likely position of electron-positron annihilation, estimated from the emissions of back-to-back γ-photons. The optimisation of its parameters is studied using Monte Carlo simulations of a 1-mm spherical source, NEMA IEC and XCAT phantoms inside the ideal J-PET scanner. The combination of high-pass filters which included the TOF filtered back-projection (FBP), resulted in spatial resolution, 1.5 times higher in the axial direction than for the conventional 3D FBP. For realistic 10-minute scans of NEMA IEC and XCAT, which require a trade-off between the noise and spatial resolution, the need for Gaussian TOF kernel components, coupled with median post-filtering, is demonstrated. The best sets of 3D filter parameters were obtained by the Nelder-Mead minimisation of the mean squared error between the resulting and reference images. The approach allows training the reconstruction algorithm for custom scans, using the IEC phantom, when the temporal resolution is below 50 ps. The image quality parameters, estimated for the best outcomes, were systematically better than for the non-TOF FBP.


Subject(s)
Algorithms , Positron-Emission Tomography , Humans , Image Processing, Computer-Assisted , Monte Carlo Method , Phantoms, Imaging
3.
Phys Med Biol ; 66(17)2021 09 01.
Article in English | MEDLINE | ID: mdl-34289460

ABSTRACT

The purpose of the presented research is estimation of the performance characteristics of the economic total-body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with cross section of 6 mm times 30 mm and length of 140 or 200 cm) arranged in two layers in regular 24-sided polygon circumscribing a circle with the diameter of 78.6 cm. For the TB-J-PET with an axial field-of-view (AFOV) of 200 cm, a spatial resolutions (SRs) of 3.7 mm (transversal) and 4.9 mm (axial) are achieved. The noise equivalent count rate (NECR) peak of 630 kcps is expected at 30 kBq cc-1. Activity concentration and the sensitivity at the center amounts to 38 cps kBq-1. The scatter fraction (SF) is estimated to 36.2 %. The values of SF and SR are comparable to those obtained for the state-of-the-art clinical PET scanners and the first total-body tomographs: uExplorer and PennPET. With respect to the standard PET systems with AFOV in the range from 16 to 26 cm, the TB-J-PET is characterized by an increase in NECR approximately by factor of 4 and by the increase of the whole-body sensitivity by factor of 12.6 to 38. The time-of-flight resolution for the TB-J-PET is expected to be at the level of CRT = 240 ps full width at half maximum. For the TB-J-PET with an AFOV of 140 cm, an image quality of the reconstructed images of a NEMA IEC phantom was presented with a contrast recovery coefficient and a background variability parameters. The increase of the whole-body sensitivity and NECR estimated for the TB-J-PET with respect to current commercial PET systems makes the TB-J-PET a promising cost-effective solution for the broad clinical applications of total-body PET scanners. TB-J-PET may constitute an economic alternative for the crystal TB-PET scanners, since plastic scintillators are much cheaper than BGO or LYSO crystals and axial arrangement of the strips significantly reduces the costs of readout electronics and SiPMs.


Subject(s)
Plastics , Positron-Emission Tomography , Phantoms, Imaging , Tomography, X-Ray Computed
4.
Phys Med ; 80: 230-242, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33190079

ABSTRACT

In this paper we introduce a semi-analytic algorithm for 3-dimensional image reconstruction for positron emission tomography (PET). The method consists of the back-projection of the acquired data into the most likely image voxel according to time-of-flight (TOF) information, followed by the filtering step in the image space using an iterative optimization algorithm with a total variation (TV) regularization. TV regularization in image space is more computationally efficient than usual iterative optimization methods for PET reconstruction with full system matrix that use TV regularization. The efficiency comes from the one-time TOF back-projection step that might also be described as a reformatting of the acquired data. An important aspect of our work concerns the evaluation of the filter operator of the linear transform mapping an original radioactive tracer distribution into the TOF back-projected image. We obtain concise, closed-form analytical formula for the filter operator. The proposed method is validated with the Monte Carlo simulations of the NEMA IEC phantom using a one-layer, 50 cm-long cylindrical device called Jagiellonian PET scanner. The results show a better image quality compared with the reference TOF maximum likelihood expectation maximization algorithm.


Subject(s)
Image Processing, Computer-Assisted , Positron-Emission Tomography , Algorithms , Imaging, Three-Dimensional , Phantoms, Imaging
5.
EJNMMI Phys ; 7(1): 44, 2020 Jun 30.
Article in English | MEDLINE | ID: mdl-32607664

ABSTRACT

PURPOSE: In living organisms, the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511 keV photons. In this article, we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include the (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using 2γ annihilations and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. METHODS: Simulations are conducted assuming that radiopharmaceutical is labeled with 44Sc isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution, the four cases were considered assuming that CRT is equal to 500 ps, 140 ps, 50 ps, and 10 ps. RESULTS: The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences (2γ+γprompt) is larger by a factor of 13.5 (for LYSO PET) and by factor of 5.2 (for plastic PET) with respect to the sensitivity for the standard 2γ imaging by LYSO PET scanners with AFOV = 20 cm. The spatial resolution of the ortho-positronium image is comparable with the resolution achievable when using TOF-FBP algorithms already for CRT = 50 ps. For the 20-min scan, the resolution better than 20 ps is expected for the mean ortho-positronium lifetime image determination. CONCLUSIONS: Ortho-positronium mean lifetime imaging based on the annihilations into two photons and prompt gamma is shown to be feasible with the advent of the high sensitivity total-body PET systems and time resolution of the order of tens of picoseconds.

6.
EJNMMI Phys ; 7(1): 39, 2020 Jun 05.
Article in English | MEDLINE | ID: mdl-32504254

ABSTRACT

PURPOSE: The time-over-threshold (TOT) technique is being used widely due to itsimplications in developing the multi-channel readouts, mainly when fast signal processing is required. Using the TOT technique, as a measure of energy loss instead of charge integration methods, significantly reduces the signal readout costs by combining the time and energy information. Therefore, this approach can potentially be utilized in J-PET tomograph which is built from plastic scintillators characterized by fast light signals. The drawback in adopting this technique lies in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it by the J-PET tomograph setup. METHODS: The experiment was performed using a 22Na beta emitter source placed in the center of the J-PET tomograph. This isotope produces photons of two different energies: 511 keV photons from the positron annihilation (direct annihilation or through the formation of a para-positronium atom or pick-off process of ortho-positronium atoms) and a 1275 keV prompt photon. This allows the study of the correlation between TOT values and energy loss for energy ranges up to 1000 keV. Since the photon interacts predominantly via Compton scattering inside the plastic scintillator, there is no direct information of the energy deposition. However, using the J-PET geometry, one can measure the scattering angle of the interacting photon. Since the 22Na source emits photons of two different energies, it is necessary to know unambiguously the energy of incident photons and their corresponding scattering angles in order to estimate energy deposition. In summary, this work presents a dedicated algorithm developed to tag photons of different energies and studying their scattering angles to calculate the energy deposition by the interacting photons. RESULTS: A new method was elaborated to measure the energy loss by photons interacting with plastic scintillators used in the J-PET tomograph. We find the relationship between the energy loss and TOT is non-linear and can be described by the functions TOT = A0 + A1 * ln(E dep + A2) + A3 * (ln(E dep + A2))2 and TOT = A0 - A1 * A2[Formula: see text]. In addition, we also introduced a theoretical model to calculate the TOT as a function of energy loss in plastic scintillators. CONCLUSIONS: A relationship between TOT and energy loss by photons interacting inside the plastic scintillators used in J-PET scanner is established for a deposited energy range of 100-1000 keV.

7.
Addict Behav ; 93: 14-19, 2019 06.
Article in English | MEDLINE | ID: mdl-30682677

ABSTRACT

OBJECTIVE: This qualitative study identifies and describes experiences and challenges to retention of individuals with opioid use disorder (OUD) who participated in a low-threshold combined buprenorphine-peer support treatment program in Baltimore. METHODS: In-depth semi-structured interviews with staff and former clients of the Project Connections Buprenorphine Program (PCBP) (9 people) and focus group discussions with current and previous clients of PCBP (7 people) were conducted. Content analysis was used to extract themes regarding barriers to enrolling and remaining in, and transitioning from the program. RESULTS: Primary challenges identified by the participants included struggles with cravings and symptoms of withdrawal, comorbid mental health issues, criminal justice system involvement, medication stigma, and conflicts over level of flexibility regarding program requirements and the role of employment. CONCLUSIONS: This study identified several obstacles clients face when seeking care through a combined buprenorphine-peer support model. Findings highlight potential programmatic factors that can be improved and additional resources that may support treatment retention rates and better outcomes. Despite challenges, low-threshold and community-based programs can increase access to effective maintenance treatment for OUD, especially among vulnerable populations who may not have access to formal health services.


Subject(s)
Analgesics, Opioid/therapeutic use , Attitude to Health , Buprenorphine/therapeutic use , Mental Health Recovery , Opiate Substitution Treatment , Opioid-Related Disorders/drug therapy , Adult , Aged , Attitude of Health Personnel , Baltimore/epidemiology , Community Mental Health Services , Comorbidity , Craving , Criminal Law , Employment , Female , Focus Groups , Humans , Male , Mental Disorders/epidemiology , Middle Aged , Opioid-Related Disorders/epidemiology , Peer Group , Qualitative Research , Social Stigma , Substance Withdrawal Syndrome
8.
Rev Sci Instrum ; 89(10): 10F111, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399723

ABSTRACT

The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

9.
Rev Sci Instrum ; 89(10): 10D131, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399789

ABSTRACT

This paper reports on impurity behavior in a set of hybrid discharges with Ne seeding-one of the techniques considered to reduce the power load on reactor walls. A series of experiments carried out with light gas injection on JET with the ITER-Like-Wall (ILW) suggests increased tungsten release and impurity accumulation [C. Challis et al., Europhysics Conference Abstracts 41F, 2.153 (2017)]. The presented method relies mainly on the measurements collected by vacuum-ultra-violet and soft X-ray (SXR) diagnostics including the "SOXMOS" spectrometer and the SXR camera system. Both diagnostics have some limitations. Consequently, only a combination of measurements from these systems is able to provide comprehensive information about high-Z [e.g., tungsten (W)] and mid-Z [nickel (Ni), iron (Fe), copper (Cu), and molybdenum (Mo)] impurities for their further quantitative diagnosis. Moreover, thanks to the large number of the SXR lines of sight, determination of a 2D radiation profile was also possible. Additionally, the experimental results were compared with numerical modeling based on integrated simulations with COREDIV. Detailed analysis confirmed that during seeding experiments, higher tungsten release is observed, which was also found in the past. Additionally, it was noticed that besides W, the contribution of molybdenum to SXR radiation was greater, which can be explained by the place of its origin.

10.
IEEE Trans Med Imaging ; 37(11): 2526-2535, 2018 11.
Article in English | MEDLINE | ID: mdl-29994248

ABSTRACT

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian positron emission tomography scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead, we introduce a field programmable gate array system-on-chip platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search, and region-of-response reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.


Subject(s)
Image Interpretation, Computer-Assisted/instrumentation , Positron-Emission Tomography/instrumentation , Algorithms , Equipment Design , Image Interpretation, Computer-Assisted/methods , Positron-Emission Tomography/methods
11.
Eur Phys J C Part Fields ; 78(11): 970, 2018.
Article in English | MEDLINE | ID: mdl-30636927

ABSTRACT

J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82 ∘ (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40 ∘ (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.

12.
Phys Med Biol ; 62(12): 5076-5097, 2017 Jun 21.
Article in English | MEDLINE | ID: mdl-28452337

ABSTRACT

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the kernel density estimation method. We obtain simple, closed-form analytical formulae for time resolution. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built from a 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results obtained for the J-PET scanner equipped with vacuum tube photomultipliers are consistent.


Subject(s)
Positron-Emission Tomography/instrumentation , Scintillation Counting/instrumentation , Equipment Design , Humans , Plastics , Time Factors
13.
Rev Sci Instrum ; 87(11): 11D304, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910389

ABSTRACT

Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. An overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

14.
Article in English | MEDLINE | ID: mdl-27547122

ABSTRACT

We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the [Formula: see text] decays with angular and energy resolution equal to [Formula: see text] and [Formula: see text], respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

15.
Geburtshilfe Frauenheilkd ; 76(5): 525-534, 2016 May.
Article in English | MEDLINE | ID: mdl-27239061

ABSTRACT

Conventional chemotherapy is generally administered in high doses followed by a treatment-free period to give the body needful time to recover. This "maximum tolerated dose" approach results in high response rates. However, long periods between therapy cycles can lead to development of resistance mechanisms and consequently disease progression. One of the most interesting alternative strategies is metronomic chemotherapy. This concept relies on the continuous administration of chemotherapy at low doses and aims at targeting endothelial cells in the tumor bed as well. Recently, metronomic chemotherapy has been incorporated into the recommendations issued by the German AGO expert panel (www.ago-online.de). A systematic review of PubMed/Medline, ClinicalTrials.gov, the European Clinical Trials Database (EudraCT) and the Cochrane Database was conducted. In the present review, we discuss the current evidence on metronomic chemotherapy in metastatic breast cancer.

16.
Geburtshilfe Frauenheilkd ; 76(2): 176-181, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26941451

ABSTRACT

Endometriosis is a common condition in women of reproductive age. According to several epidemiological studies endometriosis may be associated with increased risk of various malignancies. However, endometriosis-associated malignancy (EAM) is defined by certain histological criteria. About 80 % of EAM have been found in the ovary, whereas 20 % are localized in extragonadal sites like intestine, rectovaginal septum, abdominal wall, pleura and others. Some authors suggest that EAM arise from atypical endometriosis as an intermediate lesion between endometriosis and cancer. Moreover, a number of genetic alterations, like loss of heterozygosity (LOH), PTEN, ARID1 A and p53 mutations have been found in both endometriosis and EAM. Endometriosis-associated ovarian cancer (EAOC) is mostly a well or intermediately differentiated tumor of endometrioid or clear cell histological sub-type. Women affected by EAOC are on average five to ten years younger than non-EAOC patients; in most of the cases EAOC is a low stage disease with favorable clinical outcome. Since EAM is a rare condition systematic data on EAM are still missing. A systematic retrospective study on endometriosis-associated malignancies (EAM study) is currently being conducted by the Endometriosis Research Foundation together with the study groups on ovarian and uterine tumors of the working group for gynecological oncology (AGO) (gyn@mlk-berlin.de).

17.
Geburtshilfe Frauenheilkd ; 75(3): 232-237, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25914415

ABSTRACT

Circulating tumor cells (CTCs) can be detected in the peripheral blood of breast cancer patients with early and metastatic disease. Recent data suggest that immune pathologic characteristics between the primary tumor, metastatic colonies and CTCs are discordant and that CTCs possess an independent phenotype that is associated with prognosis and treatment efficacy. Large scale gene expression analysis has provided the possibility to stratify breast cancer according to the gene expression fingerprint of primary tumor tissue into five intrinsic molecular subtypes which can be associated with different clinical outcome. As a consequence of the different prognostic power of primary tumors' characteristics and CTCs several groups have started to investigate if CTCs might be disseminated differentially within these breast cancer subtypes. They determined the CTC number in immunohistochemical subtypes to validate if CTCs may provide differential and more specific prognostic information within each subtype. This review provides an overview of the outcome of some recently published data gathered from early and metastatic breast cancer.

18.
Anticancer Res ; 31(12): 4423-8, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22199310

ABSTRACT

BACKGROUND: Disseminated tumor cells (DTCs) in bone marrow (BM) occur in 30-40% of primary breast cancer patients. An impaired bone microenvironment may lead to reduced bone density and osteoporosis affecting the BM as a homing site for DTCs. The bone mineral density (BMD) and its correlation to DTC in BM was evaluated. MATERIALS AND METHODS: One hundred and eighty-one women (70 premenopausal, 111 postmenopausal) underwent quantitative ultrasonometry before adjuvant chemotherapy. BM aspirates were analyzed by immunocytochemistry using the ACIS system (Chromavision) based on immunostaining. RESULTS: DTCs were detected in 39% of the patients. Positive BM status correlated significantly with the nodal status. BMD was significantly reduced in the postmenopausal patients (p=0.003). Smaller tumors and higher BMD correlated significantly (p<0.014). Fifty percent of the patients with preclinical osteoporosis were BM positive, whereas 37% with normal or osteopenic BMD had DTCs. CONCLUSION: An impaired bone micro-environment as found in preclinical osteoporosis might be a homing site for DTCs.


Subject(s)
Bone and Bones/pathology , Breast Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Bone Density , Bone Marrow/pathology , Breast Neoplasms/complications , Chemotherapy, Adjuvant/methods , Female , Humans , Immunohistochemistry/methods , Immunophenotyping , Middle Aged , Neoplastic Cells, Circulating , Osteoporosis/etiology , Postmenopause , Premenopause
19.
Geburtshilfe Frauenheilkd ; 71(12): 1067-1072, 2011 Dec.
Article in English | MEDLINE | ID: mdl-28435167

ABSTRACT

Disseminated tumor cells (DTC) are routinely detected in bone marrow (BM) in 30-40 % of primary breast cancer patients. Positive BM status at the time of diagnosis as well as DTC persistence after therapy are strong independent prognostic factors. Since repeated BM aspirations are not well tolerated, detection of single tumor cells in peripheral blood (circulating tumor cells; CTC) have become of interest in recent years. CTC are found in 10-80 % breast cancer patients. Variability can be explained by stage of the disease and detection method. Emerging data have shown CTC to be of prognostic relevance for both, patients with primary and metastatic disease. The assessment of CTC in blood may become an important biomarker for prognostication and therapy monitoring. Determination of their molecular characteristics will enable specific targeting of minimal residual as well as metastatic disease. This review summarizes recent research and future perspectives.

SELECTION OF CITATIONS
SEARCH DETAIL
...