Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Article in English | MEDLINE | ID: mdl-38231234

ABSTRACT

PURPOSE: To date, it remains unclear whether superior or anterior plating is the best option for treating midshaft clavicular fractures. The aim of this study was to compare both techniques with regard to the incidence of implant removal due to implant irritation, risk of complications, time to union, and function. METHODS: In this retrospective cohort study, all midshaft clavicular fractures treated operatively between 2017 and 2020 in two hospitals in Switzerland were analyzed. The participating hospitals differed with regard to their standard practice; one offered superior plating only, while the other predominantly employed an anterior plate. The primary outcome was the incidence of implant removal for irritation. Secondary outcomes were time to union, complications, re-interventions, and range of motion during the follow-up period of at least 6 months. RESULTS: In total, 168 patients were included in the study of which 81 (48%) received anterior plating and 87 (52%) superior plating. The overall mean age was 45 years (SD 16). There was no significant difference between anterior and superior plating with regard to implant removal (58.5% versus 57.1%, p = 0.887), infection (5.7% versus 1.8%, p = 0.071), and time to union (median 48 weeks versus 52 weeks, p = 0.643). Data on range of motion were available in 71 patients. There was no significant difference in anteflexion (median 180 degrees anterior versus 180 degrees superior) and abduction (median 180 degrees anterior versus 180 degrees superior) between the two groups. CONCLUSION: This retrospective cohort study did not find sufficient evidence to recommend one implant position over the other for midshaft clavicular fractures with regard to removal due to irritation. Time to union was similar and Infections were equally rare in both groups. Notably, a considerable number of patients in both groups had their implants removed due to irritation. Larger prospective studies are needed to determine how much plate position contributes to the occurrence of irritation and whether other patient or implant-related factors might play a role. Until this is clarified, implant position should be based on surgeons preference and experience.

2.
Praxis (Bern 1994) ; 112(2): 117-119, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36722104

ABSTRACT

This article describes the case of a woman who unknowingly swallowed several fishbones, one of which perforated the intestinal wall and subsequently formed an intra-abdominal abscess due to the foreign body reaction.


Subject(s)
Abdominal Abscess , Foreign-Body Reaction , Female , Humans , Abdominal Abscess/etiology , Deglutition , Fishes , Bone and Bones , Intestines/injuries
3.
Front Surg ; 10: 1120399, 2023.
Article in English | MEDLINE | ID: mdl-36755767

ABSTRACT

Background: Historically rib fractures have been typically treated non-operatively. Recent studies showed promising results after osteosynthesis of rib fractures in trauma patients with flail segments or multiple rib fractures. However, there is a paucity of data on rib fixation after cardiopulmonary resuscitation (CPR). This study evaluated the outcomes of patients who received rib fixation after CPR. Methods: Adult patients who received surgical fixation of rib fractures sustained during CPR between 2010 and 2020 were eligible for inclusion in this retrospective study. Outcome measures included complications, quality of life (EQ 5D 5L) and level of dyspnea. Results: Nineteen patients were included with a mean age of 66.8 years. The mean number of fractured ribs was ten, seven patients additionally had a sternum fracture. Pneumonia occurred in 15 patients (74%), of which 13 were diagnosed preoperatively and 2 post-operatively. Six patients developed a postoperative pneumothorax, none of which required revision surgery. One patient showed persistent flail chest after rib fixation and required additional fixation of a concomitant sternum fracture. One infection of the surgical site of sternal plate occurred, while no further surgery related complications were reported. Mean EQ-5D-5L was 0.908 and the average EQ VAS was 80. One patient reported persisting dyspnea. Conclusion: To date, this is the largest reported cohort of patients who received rib fixation for fractures sustained during CPR. No complications associated with rib fixation were reported whereas one infection after sternal fixation did occur. Current follow-up demonstrated a good long-term quality of life after fixation, warranting further studies on this topic. Deeper knowledge on this subject would be beneficial for a wide spectrum of physicians.

4.
Dtsch Arztebl Int ; 119(16): 279-284, 2022 04 22.
Article in English | MEDLINE | ID: mdl-35140009

ABSTRACT

BACKGROUND: The utility of routine x-rays after the osteosynthesis of distal radius fractures and ankle fractures is questionable. We performed a trial to determine whether such x-rays are justified in patients who have undergone standardized imaging with C-arm fluoroscopy during surgery. METHODS: Patients requiring surgery for a distal radius fracture or an ankle fracture were candidates for inclusion in this prospective, randomized, controlled, non-blinded trial. Standardized intraoperative images were obtained with C-arm fluoroscopy and stored at the end of the operation. The next day, patients in the control group underwent imaging with a standard postoperative x-ray, while those in the intervention group did not. The primary endpoint was a change in the treatment plan, defined as additional imaging or a second operation. The secondary endpoints included the range of motion, pain as rated on the Visual Analog Scale, and a functional outcome analysis (PRWE/FAOS). RESULTS: 316 patients were included in the trial (163 in the control group, 153 in the intervention group), of whom 202 (64%) had radius fractures and 114 (36%) had ankle fractures. The treatment plan changed in twelve patients (3.8%; four in the control group and eight in the intervention group), seven of whom (2.2%; three in the control group and four in the intervention group) underwent a second operation. The frequency of changes in the treatment plan and of reoperations was comparable in the two groups (p = 0.36). On follow-up at six weeks and one year, the results with respect to functional outcomes and pain were comparable. CONCLUSION: In this trial, routine postoperative x-rays after the osteosynthesis of distal radial fractures and ankle fractures did not improve the care of patients who had undergone standardized intraoperative imaging.


Subject(s)
Ankle Fractures , Radius Fractures , Ankle Fractures/diagnostic imaging , Ankle Fractures/etiology , Ankle Fractures/surgery , Bone Plates , Fracture Fixation, Internal/methods , Humans , Pain/etiology , Prospective Studies , Radius , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Treatment Outcome , X-Rays
5.
Eur J Trauma Emerg Surg ; 48(4): 3165-3169, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35024873

ABSTRACT

PURPOSE: Nonunion of traumatic rib fractures is a clinical/radiological diagnosis caused by an alteration of bone healing reparative process. Since it is a painful condition, nonunion has a significative impact on patient's morbidity and quality of life. The aim of this study was to evaluate the outcomes after surgical stabilization of ribs affected by nonunion after traumatic fractures. METHODS: We conducted a retrospective cohort analysis of all patients who were treated with surgical stabilization of nonunion after traumatic rib fractures. We analyzed demographic data as well as clinical and patient-reported outcomes. RESULTS: Nineteen patients were identified and included in this analysis. Median age was 49 years (range 25-69 years). Mean length of stay was 5.4 days. No in-hospital mortality was observed. After a median follow-up of 46.94 months (range 0-103), 16 (84.2%) patients were completely asymptomatic, while 3 (15.8%) were still suffering from pain after surgery. CONCLUSIONS: Surgical stabilization in patients affected by rib nonunion can be safely performed with few complications, good clinical outcomes and satisfactory quality of life.


Subject(s)
Rib Fractures , Adult , Aged , Fracture Fixation, Internal , Humans , Middle Aged , Quality of Life , Radiography , Retrospective Studies , Rib Fractures/complications , Rib Fractures/diagnostic imaging , Rib Fractures/surgery
6.
Eur J Trauma Emerg Surg ; 48(1): 255-264, 2022 Feb.
Article in English | MEDLINE | ID: mdl-32876772

ABSTRACT

PURPOSE: The primary aim of this study was to assess the long-term quality of life and functional outcome after rib fracture fixation for patients with multiple rib fractures or flail chest. Secondarily, this study sought to identify risk factors associated with the quality of life. METHODS: A retrospective cohort study with a follow-up by questionnaire was performed at a level-1 trauma center in Switzerland. All adult patients with three or more rib fractures treated with rib fixation between 2010 and 2018 were eligible for inclusion. All outcomes were independently assessed for patients with multiple rib fractures and patients with a flail chest. The outcome measures were quality of life, level of dyspnea, return to work, implant irritation, and implant removal after a minimum of 12 months of follow-up. Quality of life was assessed using the EuroQol five-dimensional five-level questionnaire (EQ-5D-5L) and level of dyspnea was determined with the modified Medical Research Council dyspnea (mMRC) scale. RESULTS: The survey was completed by 74 out of 102 patients (73%) at a median follow-up of 26 months (IQR 15-37). The median EQ-5D utility index score was 0.91 (0.89-1.0), which was equivalent to the reference population (0.902, p = 0.523). The vast majority of patients experienced 'no problems' or 'slight problems' in any of the EQ-5D-5L dimensions. The complication rate associated with rib fracture fixation was low, implant-related irritation was the most common long-term sequela and occurred in 31% of patients. In multivariable regression analyses, total length of stay on the intensive care unit (ICU-LOS) was independently associated with a worse quality of life. CONCLUSIONS: Patients who underwent rib fracture fixation for multiple rib fractures or flail chest after severe chest trauma experienced a good quality of life at least 1 year after surgery. A longer ICU-LOS was independently associated with impaired quality of life. In addition, there were no significant differences in the long-term quality of life and functional outcome between patients with multiple rib fractures and a flail chest. Implant-related irritation was the most important long-term sequela and occurred in one-third of patients.


Subject(s)
Quality of Life , Rib Fractures , Adult , Fracture Fixation , Fracture Fixation, Internal , Humans , Length of Stay , Retrospective Studies , Rib Fractures/surgery , Ribs
7.
Eur J Trauma Emerg Surg ; 48(3): 2477-2482, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34625816

ABSTRACT

PURPOSE: In most hospitals, acquiring postoperative X-rays after operative treatment of a fracture is the standard. Its value, however, after operative treatment for clavicular fractures is questionable. The aim of this study was to evaluate how often there is a change in treatment plan due to the postoperative X-ray after operative treatment of clavicular fractures when intra-operative images were acquired. METHODS: This was a retrospective cohort study performed in a level I trauma center. All consecutive patients treated surgically for clavicular fractures between 2014 and 2018 were included. The primary outcome was any deviation from the standard postoperative protocol resulting from the routine postoperative X-ray taken within the first 72 h after surgery. Secondary outcomes included all other complications and re-interventions performed during follow-up of patients with at least 6-month follow-up. RESULTS: In total, 241 patients were included in the study with a mean age of 42 years (SD 17). Only one patient had an abnormality on postoperative X-ray necessitating additional CT-scanning. No additional re-interventions or deviations from standard postoperative protocol were required. For secondary analyses, 187 patients were available. Seven patients had a late implant associated infection: one was detected at the time of implant removal and six during revision for non-union. Six patients had aseptic complications: four with non-union and two with implant failure. One-hundred and seven patients had an implant removal due to irritation after consolidation. CONCLUSION: Routinely performing postoperative X-rays after osteosynthesis for clavicular fractures seems unnecessary. Refraining from performing unnecessary radiographs will decrease exposure to radiation and likely have a beneficial effect on costs, length of hospital stay as well as healthcare consumption. This study was performed in a single center; therefore, it remains to be seen whether the findings are reproducible in another setting.


Subject(s)
Bone Plates , Fractures, Bone , Adult , Bone Plates/adverse effects , Clavicle/diagnostic imaging , Clavicle/injuries , Clavicle/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/complications , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Retrospective Studies , Treatment Outcome , X-Rays
8.
Eur J Trauma Emerg Surg ; 47(4): 1105-1114, 2021 Aug.
Article in English | MEDLINE | ID: mdl-31768585

ABSTRACT

PURPOSE: The primary aim of this retrospective cohort study was to evaluate the pulmonary function after rib fixation for patients with multiple rib fractures and flail chest. Secondary, a systematic review was performed to give an overview of the current literature and to allow comparison with our results. METHODS: All adult (≥ 18 years) patients who underwent rib fixation for multiple rib fractures or flail chest between 2010 and 2018 and who received a control pulmonary function test during the postoperative follow-up at our level-1 trauma center were retrospectively reviewed. Secondary, the PubMed, EMBASE and Cochrane databases were searched to identify studies reporting on the pulmonary function after rib fixation. The primary outcome parameters were the forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC ratio, maximum vital capacity (VCmax), total lung capacity (TLC), residual volume (RV), and RV/TC ratio. RESULTS: Of the 103 patients who underwent rib fixation, a total of 61 (59%) patients underwent a pulmonary function test in our hospital and were ultimately included. In the majority of patients all pulmonary function parameters fell within the normal range of the reference values. Obstructive impairment was predominantly seen in patients with pre-existing chronic obstructive pulmonary disease (COPD). Patients with multiple rib fractures had better recovery compared to those with a flail chest. The systematic review included a total of 15 studies and showed comparable results. CONCLUSION: The present study demonstrates that rib fixation for multiple rib fractures or flail chest results in adequate recovery of the pulmonary function within 3 months after surgery. In addition, based on the current literature, further gradual improvement to maximum pulmonary values appears to occur during the first 12 months after rib fixation.


Subject(s)
Flail Chest , Fractures, Multiple , Rib Fractures , Adult , Flail Chest/surgery , Fracture Fixation, Internal , Humans , Retrospective Studies , Rib Fractures/diagnostic imaging , Rib Fractures/surgery , Ribs
9.
Knee Surg Sports Traumatol Arthrosc ; 28(12): 3899-3905, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32030500

ABSTRACT

PURPOSE: The reasons leading to rotational tibial malalignment in total knee arthroplasties (TKAs) remain unclear. A previous cadaver study has shown an increase in internal rotation of the anatomical tibial axis (ATA) after the tibial cut. This study investigates the influence of tibial slope on the ATA and the size of the resected tibial surface. METHODS: CT scans of 20 cadaver knees were orientated in a standardized coordinate system and used to determine the position of the centres of rotation of the medial and lateral tibial articular surfaces and, hence, of the ATA, after a virtual resection of 6 mm with 0°, 3.5°, 7° and 10° slope, respectively. Furthermore, at each slope, the radii of the medial and lateral tibial articular surfaces after resection were calculated. RESULTS: Compared to resection of 6 mm with 0° slope, a slope of 3.5° resulted in a mean external rotation of the ATA of 0.9° (SD, 1.5°; P = 0.025). A slope of 7° resulted in a mean external rotation of the ATA of 1.0° (SD 2.0°; P = 0.030) and a slope of 10° had no influence on the rotation of the ATA. The radii of the medial and lateral articular surfaces of the cut tibiae were larger than those of the uncut tibia (P < 0.001). CONCLUSION: Differences in the posterior tibial slope should not contribute to a rotational malalignment when using the ATA to align the prosthetic tibial plateau. Although statistically significant, the change in ATA with increasing slope was negligible.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Tibia/anatomy & histology , Tibia/surgery , Aged, 80 and over , Cadaver , Female , Humans , Knee Joint/anatomy & histology , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Rotation , Tibia/diagnostic imaging , Tomography, X-Ray Computed
10.
Int Orthop ; 39(12): 2347-53, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26156716

ABSTRACT

INTRODUCTION: Despite intensive research, current total knee arthroplasty (TKA) designs do not always provide the correct kinematics for the native joint and thus further optimisation is necessary. Several studies support the importance of malrotation of the tibial components in the failure of TKA. We hypothesise that using the anatomical tibial axis (ATA) to align tibial component rotation on the resected tibial surface may lead to an internal rotation error due to relative anterior shift of the lateral articular surface centre compared to the medial one. The aim of this study was to compare the anatomical tibial axis of the physiological tibial joint surface to the resected one. METHOD: Twenty formalin-fixed cadaveric knees were obtained for study. After computed tomography scanning the data of each specimen were entered into a standardised coordinate system and virtual bone cuts were performed with 6, 8 and 10 mm resection depths. The positions of the articular surface centres were determined at each resection depth. RESULTS: The lateral articular surface centre had moved anteriorly after the resection by a mean 1.475 mm, while the medial one had not changed significantly. Resecting the tibia at a 6-mm cut and using the transverse tibial axis to align the prosthetic tibial plateau will result in a mean 4.0° (95 % confidence interval, 2.5-5.5°) of internal rotation compared to the uncut tibia. DISCUSSION: The ATA lies in 6 degrees of external rotation compared to the perpendicular to the posterior tibial condylar axis (PTCA). Graw et al. suggest aligning the tibial component in 10 degrees of external rotation to the latter. Thus, if we accept the above suggestion, the ATA is 4 degrees internally rotated compared to the same line on the resected proximal tibia. These prior studies appear to be in accordance with our findings. CONCLUSIONS: We conclude that using the ATA on the resected tibial surface may contribute to an internal rotation error.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Bone Malalignment/diagnostic imaging , Bone Malalignment/etiology , Tibia/diagnostic imaging , Tibia/surgery , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Bone Malalignment/physiopathology , Cadaver , Humans , Knee Joint/diagnostic imaging , Knee Joint/physiopathology , Knee Joint/surgery , Rotation , Tibia/physiopathology , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...