Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 9(1): 6737, 2019 05 01.
Article in English | MEDLINE | ID: mdl-31043639

ABSTRACT

For years, the issues related to the origin of the Goths and their early migrations in the Iron Age have been a matter of hot debate among archaeologists. Unfortunately, the lack of new independent data has precluded the evaluation of the existing hypothesis. To overcome this problem, we initiated systematic studies of the populations inhabiting the contemporary territory of Poland during the Iron Age. Here, we present an analysis of mitochondrial DNA isolated from 27 individuals (collectively called the Mas-VBIA group) excavated from an Iron Age cemetery (dated to the 2nd-4th century A.D.) attributed to Goths and located near Maslomecz, eastern Poland. We found that Mas-VBIA has similar genetic diversity to present-day Asian populations and higher diversity than that of contemporary Europeans. Our studies revealed close genetic links between the Mas-VBIA and two other Iron Age populations from the Jutland peninsula and from Kowalewko, located in western Poland. We disclosed the genetic connection between the Mas-VBIA and ancient Pontic-Caspian steppe groups. Similar connections were absent in the chronologically earlier Kowalewko and Jutland peninsula populations. The collected results seem to be consistent with the historical narrative that assumed that the Goths originated in southern Scandinavia; then, at least part of the Goth population moved south through the territory of contemporary Poland towards the Black Sea region, where they mixed with local populations and formed the Chernyakhov culture. Finally, a fraction of the Chernyakhov population returned to the southeast region of present-day Poland and established the archaeological formation called the "Maslomecz group".


Subject(s)
Genetic Structures , Genetics, Population , Human Migration , White People/genetics , Archaeology , Chromosome Mapping , Cluster Analysis , Europe , Female , Genetic Markers , Genetic Variation , Geography , Haplotypes , Humans , Male
2.
Clin Res Cardiol ; 101(5): 357-64, 2012 May.
Article in English | MEDLINE | ID: mdl-22179507

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been developed to minimize operative morbidity and mortality in high-risk symptomatic patients unfit for open surgery. With the proximity of the aortic valve annulus to the conduction system there is, however, an unknown risk of conduction disturbances necessitating monitoring and often cardiac pacing. MATERIALS AND METHODS: We enrolled 50 consecutive patients from January 2007 to 2008 in our prospective evaluation of conduction disturbances measured by surface and intracardiac ECG recordings. Baseline parameters, procedural characteristics as well as twelve-lead surface ECG and intracardiac conduction times were revealed pre-interventionally, after TAVI and at 7-day follow-up. RESULTS: TAVI was performed successfully in all patients. During 7 days of follow-up the rate for first-degree AV block raised from 14% at baseline to 44% at day 7 (p < 0.001), while rates for type II second- and third-degree were 0 versus 8% (p < 0.001) and 0 versus 12% (p < 0.001), respectively. Similarly, the prevalence of new left bundle branch block (LBBB) rose from 2 to 54% (p < 0.001). Intracardiac measurements revealed a prolongation of both AH and HV interval from 123.7 ± 41.6 to 136.6 ± 40.5 ms (p < 0.001) and from 54.8 ± 11.7 to 71.4 ± 20.0 ms (p < 0.001), respectively. Pacemaker implantation at a mean follow-up of 4.8 ± 1.2 days was subsequently performed in 23 patients (46%) due to complete AV block (12%) and type II second-degree AV block (8%) while another 13 patients (26%) received a pacemaker for the combination of new LBBB with marked HV prolongation. The high rate of first-degree AV block was primarily driven by an increase in HV interval. CONCLUSION: Cardiac conduction disturbances were common in the early experience with CoreValve implantation necessitating close surveillance for at least 1 week.


Subject(s)
Aortic Valve/surgery , Atrioventricular Block/diagnosis , Bundle-Branch Block/diagnosis , Electrocardiography , Heart Valve Prosthesis Implantation , Postoperative Complications/diagnosis , Aged , Aged, 80 and over , Atrioventricular Block/etiology , Bundle-Branch Block/etiology , Cardiac Catheterization , Female , Follow-Up Studies , Humans , Male , Pacemaker, Artificial , Prospective Studies , Prosthesis Design
3.
Surg Endosc ; 8(10): 1190-4, 1994 Oct.
Article in English | MEDLINE | ID: mdl-7809803

ABSTRACT

Laparoscopic surgery is now being applied for colonic resection, and one of the key challenges is fashioning a sound anastomosis. The biofragmentable anastomosis ring, a modern version of the Murphy Button, has been utilized in a series of experiments to develop and evaluate laparoscopic anatomotic techniques. A series of purpose-built devices were used to fashion left and right simulated colectomies as well as for a variety of other anastomoses. Survival animal experiments were performed and demonstrate the feasibility of this technique.


Subject(s)
Anastomosis, Surgical/instrumentation , Laparoscopes , Animals , Biodegradation, Environmental , Colectomy/instrumentation , Dogs , Equipment Design , Gallbladder/surgery , Gastroenterostomy/instrumentation , Rectum/surgery , Suture Techniques/instrumentation , Swine
5.
Gut ; 34(4): 483-8, 1993 Apr.
Article in English | MEDLINE | ID: mdl-8491394

ABSTRACT

The effects of bile on small bowel motility were studied in isolated, perfused rabbit terminal ileum. It was proposed that bile delivery into the distal ileum would inhibit ileal motor activity, by peptide YY (PYY) release and therefore the effect of luminal bile on motor activity was examined and PYY release measured. Luminal bile and taurocheodeoxycholic acid (10 mmol) inhibited ileal motor activity. Arterial infusion of venous effluents from a bile inhibited ileum suppressed motor activity in a second isolated ileum. This shows the presence of a humoral inhibitor of ileal motor activity. Luminal bile increased venous PYY concentrations (42.5 (8.5) to 502 (46.2) pmol/l; p < 0.01) and increased bile salt values (1.7 (0.36) to 88.6 (5.6) 10 mumol/l/l; p < 0.005). Arterial infusion of taurocheodeoxycholic acid at concentrations found in the venous effluent (100 mumol/l/l) suppressed motility (p < 0.001) but infusion of PYY at concentrations in the venous effluent (500.0 pmol/l) failed to inhibit motility. Furthermore, PYY antagonist, PYX 1, failed to reverse the bile induced inhibition of motility. Luminal bile salts inhibit terminal ileal motility and this is independent of PYY release. By slowing motility, bile salts may participate in their own absorption by the 'ileal pump' and in the 'ileal brake' mechanism.


Subject(s)
Bile Acids and Salts/physiology , Gastrointestinal Motility/physiology , Ileum/physiology , Animals , Biological Factors/blood , Carbachol/antagonists & inhibitors , Culture Techniques , Gastrointestinal Hormones/blood , Gastrointestinal Motility/drug effects , Glucagon-Like Peptides/blood , Peptide YY , Peptides/blood , Peptides/pharmacology , Rabbits , Taurodeoxycholic Acid/pharmacology , Vasoactive Intestinal Peptide/blood
6.
J Card Surg ; 5(2): 93-101, 1990 Jun.
Article in English | MEDLINE | ID: mdl-2133836

ABSTRACT

Systolic anterior motion (SAM) of the mitral valve, once considered to be pathognomonic of hypertrophic cardiomyopathy, has been reported in the absence of asymmetric septal hypertrophy. Of the 1,000 open heart operations performed with intraoperative two-dimensional epicardial echocardiography monitoring, four patients developed intraoperative dynamic left ventricular outflow obstruction associated with systolic anterior motion of the mitral valve that was not present preoperatively: three cases of mitral valve annuloplasty with Carpentier ring insertion and one of coronary artery bypass grafting. Though no patient had asymmetric septal hypertrophy or echocardiographic evidence of outflow obstruction by either preoperative cardiac catheterization or echocardiography, intraoperative two-dimensional epicardial echocardiography revealed SAM, and hyperdynamic left ventricles with three of these patients having documented left ventricular outflow tract gradients causing hemodynamic compromise. (Case 4 was hemodynamically stable following mitral valve repair, but had SAM and significant residual mitral regurgitation [MR] requiring reinstitution of cardiopulmonary bypass and re-repair). Measurement of mitral annular dimension demonstrated a normal decrease in size from diastole to systole in control operative subjects but not in the patients who developed outflow obstruction. The pathophysiology, treatment, and role of intraoperative echocardiography of dynamic left ventricular outflow tract obstruction are discussed.


Subject(s)
Echocardiography , Intraoperative Complications , Monitoring, Intraoperative , Ventricular Outflow Obstruction/etiology , Aged , Aged, 80 and over , Blood Volume/physiology , Calcinosis/surgery , Cardiac Output, Low/complications , Female , Heart Valve Diseases/surgery , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Prostheses and Implants/adverse effects , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...