Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ther Adv Cardiovasc Dis ; 18: 17539447241234655, 2024.
Article in English | MEDLINE | ID: mdl-38400698

ABSTRACT

Misplacement of pericardiocentesis catheter in central veins is a rare complication that can be managed with several methods. In this case, we report a percutaneous image-guided plug-assisted management of a misplaced pericardiocentesis catheter into the inferior vena cava through a transhepatic tract successfully occluded. This minimally invasive technique was not previously described in this setting and had a favorable long-term outcome.


Clinical case of a minimally invasive technique guided by imaging to fix a complication of a misplaced drainage catheter for pericardial hemorrhageThis clinical case reports how to manage, using a minimally invasive technique guided by imaging, an accidental puncture of the liver and the inferior vena cava during a pericardial hemorrhage drainage. The outcome was good, with technical success and a favorable outcome for the patient.


Subject(s)
Pericardiocentesis , Vena Cava, Inferior , Humans , Vena Cava, Inferior/diagnostic imaging , Pericardiocentesis/adverse effects , Veins , Catheters
2.
Eur Radiol ; 33(5): 3510-3520, 2023 May.
Article in English | MEDLINE | ID: mdl-36651956

ABSTRACT

OBJECTIVES: To evaluate anatomical and volumetric predictability of a cone beam computed tomography (CBCT)-based virtual parenchymal perfusion (VPP) software for the single-photon-emission computed tomography (SPECT)/CT imaging results during the work-up for transarterial radioembolization (TARE) procedure in patients with hepatocellular carcinoma (HCC). METHODS: VPP was evaluated retrospectively on CBCT data of patients treated by TARE for HCC. 99mTc macroaggregated albumin particles (99mTc-MAA) uptake territories on work-up SPECT/CT was used as ground truth for the evaluation. Semi-quantitative evaluation consisted of the ranking of visual consistency of the parenchymal enhancement and portal vein tumoral involvement on VPP and 99mTc-MAA SPECT/CT, using a three-rank scale and two-rank scale, respectively. Inter-reader agreement was evaluated using a kappa coefficient. Quantitative evaluation included absolute volume error calculation and Pearson correlation between volumes enhanced territories on VPP and 99mTc-MAA SPECT/CT. RESULTS: Fifty-two CBCTs were performed in 33 included patients. Semi-quantitative evaluation showed a good concordance between actual 99mTc-MAA uptake and the virtual enhanced territories in 73% and 75% of cases; a mild concordance in 12% and 10% and a poor concordance in 15%, for the two readers. Kappa coefficient was 0.86. Portal vein involvement evaluation showed a good concordance in 58.3% and 66.7% for the two readers, respectively, with a kappa coefficient of 0.82. Quantitative evaluation showed a volume error of 0.46 ± 0.78 mL [0.01-3.55], and Pearson R2 factor at 0.75 with a p value < 0.01. CONCLUSION: CBCT-based VPP software is accurate and reliable to predict 99mTc-MAA SPECT/CT anatomical and volumetric results in HCC patients during TARE. KEY POINTS: • Virtual parenchymal perfusion (VPP) software is accurate and reliable in the prediction of 99mTc-MAA SPECT volumetric and targeting results in HCC patients during transarterial radioembolization (TARE). • VPP software may be used per-operatively to optimize the microcatheter position for 90Y infusion allowing precise tumor targeting while preserving non-tumoral parenchyma. • Post-operatively, VPP software may allow an accurate estimation of the perfused volume by each arterial branch and, thus, a precise 90Y dosimetry for TARE procedures.


Subject(s)
Carcinoma, Hepatocellular , Embolization, Therapeutic , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/radiotherapy , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/radiotherapy , Retrospective Studies , Reproducibility of Results , Technetium Tc 99m Aggregated Albumin , Yttrium Radioisotopes , Tomography, Emission-Computed, Single-Photon/methods , Tomography, X-Ray Computed/methods , Cone-Beam Computed Tomography , Embolization, Therapeutic/methods , Algorithms , Software , Perfusion , Microspheres
SELECTION OF CITATIONS
SEARCH DETAIL
...