Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
1.
Radiology ; 221(2): 371-9, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11687678

ABSTRACT

PURPOSE: To develop a low-dose magnetic resonance (MR) renographic method performed with and without an angiotensin converting enzyme (ACE) inhibitor and in conjunction with gadolinium-enhanced MR angiography in patients with suspected renovascular disease. MATERIALS AND METHODS: Thirty-two patients underwent MR renography (turbo fast low-angle shot sequence: repetition time, 5 msec; echo time, 2.3 msec; flip angle, 15 degrees; one coronal image acquired every 2 seconds for 4 minutes) following intravenous injection of 2 mL of gadopentetate dimeglumine, which was repeated following intravenous injection of an ACE inhibitor. Contrast material-enhanced MR angiography was also performed. On the basis of renographic findings, renal cortex and renal medulla enhancement curves and normalized enhancement ratios were analyzed. RESULTS: The cortex and medulla showed an early transient period of enhancement within 20 seconds (vascular phase). During 1-2 minutes, a second, gradual increase in medullary enhancement, reflecting transit of filtered contrast material, was observed that was significantly greater in patients with a serum creatinine level less than 2 mg/dL (177 micromol/L) than in those with a level of 2 mg/dL or greater (P < .01). After injection of the ACE inhibitor, patients with elevated creatinine levels showed low renal medullary enhancement regardless of the presence of renal artery stenosis (RAS). However, in patients with creatinine less than 2 mg/dL, medullary enhancement ratios after injection of the ACE inhibitor were consistently lower in patients with RAS of 50% or greater than in those without stenosis (P = .02 to .08). CONCLUSION: Low-dose MR renography can be performed in the clinical setting before and after injection of an ACE inhibitor, and its potential use for evaluating decreased renal function as a consequence of RAS is promising.


Subject(s)
Contrast Media/administration & dosage , Gadolinium DTPA/administration & dosage , Radioisotope Renography/methods , Renal Artery Obstruction/diagnostic imaging , Angiotensin-Converting Enzyme Inhibitors/administration & dosage , Feasibility Studies , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged
2.
Magn Reson Imaging Clin N Am ; 9(4): 697-716, v-vi, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11694434

ABSTRACT

Recent improvements in MR technology have enabled the development of volumetric three-dimensional (3D) imaging methods for fat-suppressed T1-weighted images of the entire upper abdomen with pixel sizes of approximately 2 mm in all dimensions and with acquisition times of less than 25 seconds for breath-hold imaging. When performed with a timing scheme, dynamic contrast-enhanced volumetric imaging of the liver can be performed with selective imaging during the arterial phase and portal venous phase of enhancement. The volumetric data sets can be reconstructed in any oblique plane, enabling improved detection, localization, and characterization of small liver lesions. The combination of high-resolution isotropic pixels and accurate timing also permits angiographic reconstructions of the 3D images, producing MR angiography and venography that can be useful in therapeutic planning, such as for catheter-based interventions or surgical resections or transplantation. Additionally, with use of a hepatobiliary contrast agent such as mangafodipir, T1-weighted volumetric MR cholangiography can be performed in patients with nonobstructed systems for depiction of intrahepatic biliary anatomy.


Subject(s)
Liver/pathology , Magnetic Resonance Imaging/methods , Bile Ducts/anatomy & histology , Bile Ducts/pathology , Contrast Media , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Liver/anatomy & histology , Liver/blood supply , Magnetic Resonance Angiography , Magnetic Resonance Imaging/instrumentation , Portal Vein/anatomy & histology , Portal Vein/pathology
3.
AJR Am J Roentgenol ; 177(5): 1101-7, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11641180

ABSTRACT

OBJECTIVE: Our purpose was to evaluate a comprehensive MR imaging strategy for recipients of liver transplants that relies on dynamic interpolated three-dimensional (3D) MR imaging for simultaneous vascular, parenchymal, and extrahepatic imaging. MATERIALS AND METHODS: Twenty-three consecutive adult patients underwent 30 MR imaging examinations between 2 days and 99 months (mean, 15 months) after transplantation using a breath-hold 3D gradient-echo sequence (TR range/TE range, 3.7-4.7/1.8-1.9; flip angle, 12-30 degrees ) with an intermittent fat-saturation pulse and interpolation in the section-select direction to enable pixel size 3 mm or less in all dimensions. Unenhanced and triphasic contrast-enhanced 3D imaging (average dose, 0.13 mmol/kg of gadopentetate dimeglumine) was performed. A subset of patients (n = 13) also underwent MR cholangiopancreatography using half-Fourier single-shot turbo spin-echo imaging. MR imaging examinations were correlated with digital subtraction angiography (n = 8), contrast-enhanced cholangiography (n = 9), sonography (n = 13), and histopathology (n = 14). RESULTS: MR imaging revealed abnormal findings in 27 (90%) of 30 examinations, including vascular disease in nine, biliary complications in four, and evidence of intra- or extra-hepatic hepatocellular carcinoma recurrence in six. Digital subtraction angiography confirmed seven MR angiography examinations but suggested disease overestimation in one. Contrast-enhanced cholangiography confirmed findings of MR cholangiopancreatography in seven cases but suggested disease underestimation in two. CONCLUSION: Dynamic interpolated 3D MR imaging combined with dedicated MR cholangiopancreatography can provide a comprehensive assessment of vascular, biliary, parenchymal, and extrahepatic complications in most recipients of liver transplants.


Subject(s)
Cholangiography , Cholestasis, Extrahepatic/diagnosis , Common Bile Duct Diseases/diagnosis , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Liver Transplantation , Liver/blood supply , Magnetic Resonance Imaging , Postoperative Complications/diagnosis , Vascular Diseases/diagnosis , Adult , Aged , Anastomosis, Surgical , Angiography, Digital Subtraction , Female , Humans , Magnetic Resonance Angiography , Male , Middle Aged , Sensitivity and Specificity
4.
Clin Imaging ; 25(4): 251-7, 2001.
Article in English | MEDLINE | ID: mdl-11566085

ABSTRACT

Transesophageal echocardiography (TEE) is the procedure of choice for identifying aortic atheromas, which may result in stroke, transient ischemic attack and peripheral embolization. However, because of anatomic constraints, the innominate artery may not be visualized. We investigated gadolinium-enhanced MR angiography (MRA) as an alternative technique for evaluation of suspected atheromas of the innominate artery. From a retrospective review of 520 examinations, we identified five patients who had innominate artery atheromas diagnosed prospectively with gadolinium-enhanced MRA who also underwent TEE within 1 month. A total of 10 innominate artery atheromas were demonstrated on MRA; none of these were visualized on TEE. One patient had three atheromas, two patients had two atheromas and three patients had one atheroma. They ranged in size from 3 mm to 1.5 cm (mean 6.5 mm). One atheroma was flat, two were filiform, and seven were protruding. Gadolinium-enhanced MRA is superior to TEE for the diagnosis of atheromas of the innominate artery. In the setting of right cerebral or right arm embolization, when no source is seen in the arch on TEE, gadolinium-enhanced MRA should be considered.


Subject(s)
Arteriosclerosis/diagnosis , Brachiocephalic Trunk , Magnetic Resonance Angiography/methods , Aged , Aged, 80 and over , Arteriosclerosis/pathology , Brachiocephalic Trunk/pathology , Contrast Media , Echocardiography, Transesophageal , Female , Gadolinium , Humans , Middle Aged , Retrospective Studies
5.
J Am Soc Echocardiogr ; 14(8): 842-5, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11490337

ABSTRACT

Acquired communication between the aorta and the pulmonary artery is a rare phenomenon. We describe two patients with a thoracic aortic aneurysm in whom the diagnosis of a communication with the pulmonary artery was first made on transthoracic echocardiography and then more completely elucidated by means of multiple imaging modalities: transesophageal echocardiography, epiaortic ultrasound, computed tomography, and magnetic resonance imaging. Representative images from these complementary studies are presented. A successful repair of the fistula was subsequently accomplished in both patients.


Subject(s)
Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnosis , Vascular Fistula/diagnosis , Vascular Fistula/etiology , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/surgery , Echocardiography , Humans , Magnetic Resonance Imaging , Male , Tomography, X-Ray Computed , Vascular Fistula/surgery
6.
AJR Am J Roentgenol ; 176(6): 1475-82, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11373217

ABSTRACT

OBJECTIVE: Our aim was to investigate the feasibility of MR imaging as a comprehensive preoperative imaging test for examination of liver donor candidates for adult-to-adult right lobe transplantation. SUBJECTS AND METHODS: Twenty-five consecutive donor candidates were examined at 1.5 T using a torso phased array coil with breath-hold T1- and T2-weighted imaging of the abdomen, MR cholangiography using T2-weighted turbo spin-echo imaging, and MR angiography and venography of the liver using two interpolated three-dimensional spoiled gradient-echo sequences (average dose of gadolinium contrast material, 0.17 mmol/kg). Images were interpreted for liver parenchymal and extrahepatic abnormalities; measurements of right and left lobe liver volumes; definition of hepatic arterial, portal venous, and hepatic venous anatomy; and definition of the biliary branching pattern. Findings were compared with those of conventional angiography in 13 patients, 11 of whom also had surgical findings for comparison. RESULTS: Nine patients were excluded as candidates for donation on the basis of MR imaging findings that included parenchymal or extrahepatic abnormalities in five patients, vascular anomalies in two, and biliary anomalies in three. Two patients who did not undergo surgery underwent conventional angiography that confirmed MR angiographic findings except for a small (<2 mm) accessory left hepatic artery missed on MR imaging. Of the nine patients who underwent successful right hepatectomy, all MR imaging findings were corroborated intraoperatively. In two patients, right hepatectomy was aborted at laparotomy because of intraoperative cholangiography findings; in one of them, the biliary finding was unsuspected on MR imaging. CONCLUSION: A comprehensive MR imaging examination has the potential to serve as the sole preoperative imaging modality for living adult-to-adult liver donor candidates provided improvements in definition of intrahepatic biliary anatomy can be achieved.


Subject(s)
Hepatectomy , Liver Transplantation , Living Donors , Magnetic Resonance Imaging , Adult , Angiography , Bile Ducts/anatomy & histology , Contrast Media , Feasibility Studies , Female , Hepatic Artery/anatomy & histology , Hepatic Veins/anatomy & histology , Humans , Liver/blood supply , Magnetic Resonance Angiography , Male , Portal Vein/anatomy & histology , Prospective Studies
7.
Radiology ; 219(2): 445-54, 2001 May.
Article in English | MEDLINE | ID: mdl-11323471

ABSTRACT

PURPOSE: To determine the sensitivity and specificity of magnetic resonance (MR) imaging for detection of hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) by using explantation correlation in patients with cirrhosis and no known HCC. MATERIALS AND METHODS: Seventy-one patients without a known history of HCC who underwent MR imaging and subsequent transplantation within 90 days were examined. Breath-hold turbo short inversion time inversion-recovery and/or T2-weighted turbo spin-echo MR images were obtained. Dynamic two- or three-dimensional gadolinium-enhanced gradient-echo MR images were obtained in the hepatic arterial, portal venous, and equilibrium phases. Prospective MR image interpretations were compared directly with explanted liver pathologic results. RESULTS: Eleven (15%) of 71 patients had hepatic malignancies; MR imaging enabled diagnosis of tumor in six (54%) of 11 patients. On a lesion-by-lesion basis, MR imaging depicted 11 of 20 hepatic neoplasms, for an overall sensitivity of 55%. MR imaging depicted four (80%) of five lesions larger than 2 cm, six (50%) of 12 lesions 1-2 cm, and one (33%) of three lesions smaller than 1 cm. MR imaging depicted only nine (15%) of 59 DNS: The specificities of MR imaging for detection of HCC and DNs on a per patient basis were 60 (86%) of 70 patients and 53 (85%) of 62 patients, respectively. CONCLUSION: MR imaging is insensitive for the diagnosis of small (<2-cm) HCCs and DNS:


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Liver Cirrhosis/complications , Liver Neoplasms/diagnosis , Liver/pathology , Magnetic Resonance Imaging , Adult , Aged , Carcinoma, Hepatocellular/complications , False Positive Reactions , Female , Humans , Liver Neoplasms/complications , Male , Middle Aged , Sensitivity and Specificity
10.
Radiology ; 218(1): 47-53, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11152778

ABSTRACT

PURPOSE: To determine the sensitivity of magnetic resonance (MR) imaging for detection of siderotic nodules in patients with cirrhosis and whether the frequency of hepatocellular carcinoma (HCC) and dysplastic nodules is greater if siderotic nodules are present. MATERIALS AND METHODS: MR imaging (1.5 T) was performed within 0-117 days (mean, 30 days) before liver transplantation in 77 patients. Two readers retrospectively evaluated gradient-echo (GRE) (echo time [TE], > or = 9 and 4-5 msec) and turbo short inversion time inversion-recovery or T2-weighted images for low-signal-intensity nodules. Whole-explant pathologic correlation was available in every case. RESULTS: At explantation, 28 (36%) of 77 patients had HCC, 25 (32%) had dysplastic nodules, and nine (12%) had both; 35 (45%) patients had siderotic nodules. The sensitivity of GRE imaging with 9-msec or longer TE for the detection of siderotic nodules was 80% (28 of 35) but decreased to 31% (11 of 35) with 4-5-msec TE. Frequency of HCC was not significantly higher (P =.27) in patients with (43% [15 of 35]) than in patients without (31% [13 of 42]) siderotic nodules. Frequency of dysplastic nodules also was not significantly higher (P =.42) in patients with (37% [13 of 35]) than in patients without (29% [12 of 42]) siderotic nodules. CONCLUSION: Sensitivity of MR imaging for the detection of siderotic nodules was improved with use of GRE pulse sequences with longer TEs of 9 msec or greater (80%) versus 4-5 msec (31%); however, there was no significant increased frequency of HCC or dysplastic nodules in patients with pathologically proved siderotic nodules.


Subject(s)
Carcinoma, Hepatocellular/pathology , Liver Cirrhosis/pathology , Liver Neoplasms/pathology , Magnetic Resonance Imaging , Adult , Aged , Carcinoma, Hepatocellular/epidemiology , Female , Humans , Liver Neoplasms/epidemiology , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity , Siderosis/pathology
11.
J Comput Assist Tomogr ; 24(5): 773-6, 2000.
Article in English | MEDLINE | ID: mdl-11045701

ABSTRACT

OBJECTIVE: To determine if iron containing "siderotic" nodules detected at magnetic resonance (MR) imaging are regenerative (RN) or dysplastic (DN) and to attempt to identify features that may distinguish them. MATERIAL AND METHODS: MR imaging (1.5 T) was performed on 77 cirrhotic patients who underwent orthotopic liver transplantation within 0-117 days (mean 30 days) of MR imaging. Two readers retrospectively evaluated breath-hold gradient-echo pulse sequences (echo time > or =9.0 ms, flip angle < or =45 degrees) for the presence of hypointense nodules, which were classified as micronodular (< or =3 mm), macronodular (>3 mm), or mixed. Nodule distribution was classified as focal (<5), scattered (5-20), or diffuse (>20) per slice. Thin section pathologic correlation was available in all cases, and Prussian blue iron stains were performed. RESULTS: Of 35 patients with pathologically proven siderotic nodules, 10 (29%) had at least 2 siderotic DN. MR detected siderotic nodules in 10 of 10 (100%) patients with siderotic DN and RN, and in 18 of 25 patients (72%) with siderotic RN only. CONCLUSION: Siderotic RN cannot be reliably distinguished from siderotic DN with MR imaging, and therefore the widely used term "siderotic regenerative nodule" should be avoided and replaced by "siderotic nodule."


Subject(s)
Liver Cirrhosis/pathology , Liver Regeneration , Liver/pathology , Magnetic Resonance Imaging , Siderosis/pathology , Female , Humans , Liver/physiology , Liver Cirrhosis/physiopathology , Liver Cirrhosis/surgery , Liver Transplantation , Male , Middle Aged , Retrospective Studies
12.
Echocardiography ; 17(2): 173-6, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10978977

ABSTRACT

Echocardiography demonstrated an 8-cm mass adjacent to the right side of the heart in a 79-year-old man with a history of hypertension and a repaired abdominal aortic aneurysm. The results of Doppler echocardiography and magnetic resonance imaging suggested the diagnosis of an unusually large coronary artery aneurysm, and this was confirmed with coronary angiography. At surgery, the 8- to 10-cm coronary aneurysm was resected, and the patient made an uneventful recovery.


Subject(s)
Coronary Aneurysm/diagnosis , Coronary Angiography , Echocardiography, Doppler, Color , Magnetic Resonance Imaging , Aged , Blood Flow Velocity , Coronary Aneurysm/physiopathology , Coronary Aneurysm/surgery , Coronary Circulation , Diagnosis, Differential , Humans , Male
13.
J Comput Assist Tomogr ; 24(4): 628-34, 2000.
Article in English | MEDLINE | ID: mdl-10966200

ABSTRACT

PURPOSE: The purpose of this work was to determine the sensitivity of hepatic digital subtraction arteriography (DSA) for the detection of hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) when compared with pathological findings from whole liver explants. METHOD: Twenty-one patients 30-72 years old (mean 54 years) with cirrhosis and known or clinically suspected HCC (20 prior to chemoembolization) underwent hepatic DSA with subsequent transplantation within 80 days (mean 32 days). The prospective DSA report was compared with pathologic findings from explanted livers. RESULTS: Overall, DSA detected 31 of 95 HCC lesions for a sensitivity of 33%. Of these 31 lesions, 28 were hypervascular and 3 were hypovascular. DSA detected all six HCCs measuring >5 cm, all six HCCs measuring 3-5 cm, and all five HCCs 2-3 cm, resulting in a sensitivity of 100% (17/17) for HCC >2 cm. DSA detected 7 of 18 HCCs measuring 1-2 cm (sensitivity 39%) and 7 of 60 HCCs < or =1 cm (sensitivity 12%). Overall sensitivity for DSA in detection of HCC < or =2 cm was 18% (14/78 lesions). None of 17 DNs (0.2-1.5 cm in size) was identified on DSA. CONCLUSION: DSA is insensitive to small HCC (< or =2 cm), carcinomatosis arising within nodules, and DN.


Subject(s)
Angiography, Digital Subtraction/methods , Carcinoma, Hepatocellular/diagnosis , Liver Neoplasms/diagnosis , Adult , Aged , Female , Humans , Liver Diseases/diagnosis , Liver Transplantation , Male , Middle Aged , Sensitivity and Specificity
15.
Eur Radiol ; 10(8): 1257-60, 2000.
Article in English | MEDLINE | ID: mdl-10939485

ABSTRACT

Pelvic arteriovenous malformations (PAV-Ms) are rare disorders traditionally diagnosed by conventional angiography. Breath-hold three-dimensional gadolinium-enhanced MR angiography (3D-Gd-MRA) is a state-of-the-art alternative for vascular imaging. We describe the 3D-Gd-MRA findings in two patients with PAVMs. The 3D-Gd-MRA approach provides a noninvasive and versatile method for evaluation of PAVMs that enables both angiographic assessment of the malformations and evaluation of visceral involvement, which can preclude surgical intervention.


Subject(s)
Arteriovenous Malformations/diagnosis , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Pelvis/blood supply , Adult , Aged , Arteriovenous Malformations/therapy , Contrast Media , Embolization, Therapeutic , Female , Gadolinium DTPA , Humans , Iliac Vein/abnormalities , Iliac Vein/pathology , Mesenteric Artery, Inferior/abnormalities , Mesenteric Artery, Inferior/pathology , Pregnancy , Recurrence , Sensitivity and Specificity , Vagina/blood supply , Viscera/blood supply
17.
Radiology ; 215(2): 365-72, 2000 May.
Article in English | MEDLINE | ID: mdl-10796909

ABSTRACT

PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size

Subject(s)
Contrast Media , Image Processing, Computer-Assisted/methods , Liver Diseases/diagnosis , Liver/pathology , Magnetic Resonance Imaging/methods , Adipose Tissue/pathology , Adult , Aged , Aged, 80 and over , Cohort Studies , Feasibility Studies , Female , Follow-Up Studies , Gadolinium DTPA , Hepatic Artery/pathology , Hepatic Veins/pathology , Humans , Image Enhancement/methods , Liver/blood supply , Male , Middle Aged , Portal Vein/pathology , Quality Control , Reproducibility of Results , Respiration , Vena Cava, Inferior/pathology
19.
AJR Am J Roentgenol ; 174(2): 499-508, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10658731

ABSTRACT

OBJECTIVE: We investigated the usefulness of phase-contrast MR imaging to measure renal artery velocity waveforms as an adjunct to renal MR angiography. We also examined whether an angiotensin-converting enzyme (ACE) inhibitor improves the diagnostic accuracy of waveform analysis. SUBJECTS AND METHODS: Thirty-five patients referred for MR angiography of renal arteries underwent non-breath-hold oblique sagittal velocity-encoded phase-contrast MR imaging through both renal hila (TR/TE, 24/5; flip angle, 30 degrees; signal averages, two; encoding velocity, 75 cm/sec) before and after i.v. administration of an ACE inhibitor (enalaprilat). We analyzed velocity waveforms using established Doppler sonographic criteria. A timing examination with a test bolus of gadolinium contrast material was performed to ensure optimal arterial enhancement during breath-hold gadolinium-enhanced three-dimensional gradient-echo MR angiography. RESULTS: MR phase-contrast waveform pattern analysis was 50% (9/18) sensitive and 78% (40/51) specific for the detection of renal artery stenosis equal to or greater than 60% as shown on MR angiography. Sensitivity (67%, 12/18) and specificity (84%, 42/50) increased slightly, but not significantly, after i.v. administration of an ACE inhibitor. Also, the accuracy of quantitative criteria such as acceleration time and acceleration index did not improve after the administration of ACE inhibitor. CONCLUSION: Renal hilar velocity waveforms, measured using non-breath-hold MR phase-contrast techniques with or without an ACE inhibitor, are insufficiently accurate to use in predicting renal artery stenosis.


Subject(s)
Angiotensin-Converting Enzyme Inhibitors , Contrast Media , Enalaprilat , Hypertension, Renovascular/pathology , Hypertension, Renovascular/physiopathology , Magnetic Resonance Angiography/methods , Renal Artery/physiology , Adult , Aged , Aged, 80 and over , Blood Flow Velocity , False Positive Reactions , Female , Humans , Male , Middle Aged , Sensitivity and Specificity
20.
J Comput Assist Tomogr ; 24(2): 189-96, 2000.
Article in English | MEDLINE | ID: mdl-10752877

ABSTRACT

Cirrhosis is a progressive, diffuse process of liver fibrosis that is characterized by architectural distortion and the development of a spectrum of nodules ranging from benign regenerative nodules to premalignant dysplastic nodules to overtly malignant hepatocellular carcinoma. The purpose of this essay is to demonstrate the ex vivo MR and pathology findings of these nodules as well as other masses that can be seen in the cirrhotic liver. The optimal conditions under which ex vivo imaging can be performed allow greater spatial resolution than that achieved with in vivo imaging, without artifacts that may degrade image quality. Clearly, contrast-enhanced MRI is essential for both the diagnosis and the characterization of focal lesions in the cirrhotic liver. However, the use of ex vivo imaging precludes the evaluation of these important in vivo pulse sequences.


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Image Enhancement/methods , Liver Cirrhosis/diagnosis , Liver Neoplasms/diagnosis , Magnetic Resonance Imaging/methods , Precancerous Conditions/diagnosis , Adult , Carcinoma, Hepatocellular/pathology , Female , Focal Nodular Hyperplasia/diagnosis , Humans , Liver/pathology , Liver Cirrhosis/pathology , Liver Neoplasms/pathology , Liver Regeneration , Male , Middle Aged , Precancerous Conditions/pathology , Predictive Value of Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...