Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Neurobiol Aging ; 34(1): 128-36, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22840559

ABSTRACT

UNLABELLED: Inflammatory mechanisms, like microglial activation, could be involved in the pathogenesis of Alzheimer's disease (AD). (R)-[(11)C]PK11195 (1-(2-chlorophenyl)-N-methyl-N-1(1-methylpropyl)-3-isoquinolinecarboxamide), a positron emission tomography (PET) ligand, can be used to quantify microglial activation in vivo. The purpose of this study was to assess whether increased (R)-[(11)C]PK11195 binding is present in AD and mild cognitive impairment (MCI), currently also known as "prodromal AD." METHODS: Nineteen patients with probable AD, 10 patients with prodromal AD (MCI), and 21 healthy control subjects were analyzed. Parametric images of binding potential (BP(ND)) of (R)-[(11)C]PK11195 scans were generated using receptor parametric mapping (RPM) with supervised cluster analysis. Differences between subject groups were tested using mixed model analysis, and associations between BP(ND) and cognition were evaluated using Pearson correlation coefficients. RESULTS: Voxel-wise statistical parametric mapping (SPM) analysis showed small clusters of significantly increased (R)-[(11)C]PK11195 BP(ND) in occipital lobe in AD dementia patients compared with healthy control subjects. Regions of interest (ROI)-based analyses showed no differences, with large overlap between groups. There were no differences in (R)-[(11)C]PK11195 BP(ND) between clinically stable prodromal AD patients and those who progressed to dementia, and BP(ND) did not correlate with cognitive function. CONCLUSION: Microglial activation is a subtle phenomenon occurring in AD.


Subject(s)
Alzheimer Disease/diagnostic imaging , Alzheimer Disease/pathology , Brain Mapping , Isoquinolines , Microglia/diagnostic imaging , Aged , Analysis of Variance , Carbon Radioisotopes , Cluster Analysis , Female , Humans , Magnetic Resonance Imaging , Male , Microglia/pathology , Middle Aged , Positron-Emission Tomography
2.
J Cereb Blood Flow Metab ; 27(12): 1965-74, 2007 Dec.
Article in English | MEDLINE | ID: mdl-17406654

ABSTRACT

Inflammation in Alzheimer's disease (AD) may be assessed using (R)-[(11)C]PK11195 and positron emission tomography. Data can be analyzed using the simplified reference tissue model, provided a suitable reference region is available. This study evaluates various reference regions for analyzing (R)-[(11)C]PK11195 scans in patients with mild cognitive impairment (MCI) and probable AD. Healthy subjects (n=10, 30+/-10 years and n=10, 70+/-6 years) and patients with MCI (n=10, 74+/-6 years) and probable AD (n=9, 71+/-6 years) were included. Subjects underwent a dynamic three-dimensional (R)-[(11)C]PK11195 scan including arterial sampling. Gray matter, white matter, total cerebellum and cerebrum, and cluster analysis were evaluated as reference regions. Both plasma input binding potentials of these reference regions (BP(PLASMA)) and corresponding reference region input binding potentials of a target region (BP(SRTM)) were evaluated. Simulations were performed to assess cluster analysis performance at 5% to 15% coefficient of variation noise levels. Reasonable correlations for BP(PLASMA) (R(2)=0.52 to 0.94) and BP(SRTM) (R(2)=0.59 to 0.76) were observed between results using anatomic regions and cluster analysis. For cerebellum white matter, cerebrum white matter, and total cerebrum a considerable number of unrealistic BP(SRTM) values were observed. Cluster analysis did not extract a valid reference region in 10% of the scans. Simulations showed that potentially cluster analysis suffers from negative bias in BP(PLASMA). Most anatomic regions outperformed cluster analysis in terms of absence of both scan rejection and bias. Total cerebellum is the optimal reference region in this patient category.


Subject(s)
Alzheimer Disease/diagnostic imaging , Antineoplastic Agents , Cognition Disorders/diagnostic imaging , Isoquinolines , Adult , Aged , Algorithms , Antineoplastic Agents/pharmacokinetics , Blood Volume/physiology , Cluster Analysis , Computer Simulation , Female , Humans , Image Processing, Computer-Assisted , Isoquinolines/pharmacokinetics , Magnetic Resonance Imaging , Male , Middle Aged , Models, Neurological , Positron-Emission Tomography
3.
Neuroimage ; 35(4): 1473-9, 2007 May 01.
Article in English | MEDLINE | ID: mdl-17363280

ABSTRACT

(R)-[11C]PK11195 has been used for quantifying cerebral microglial activation in vivo. In previous studies, both plasma input and reference tissue methods have been used, usually in combination with a region of interest (ROI) approach. Definition of ROIs, however, can be labourious and prone to interobserver variation. In addition, results are only obtained for predefined areas and (unexpected) signals in undefined areas may be missed. On the other hand, standard pharmacokinetic models are too sensitive to noise to calculate (R)-[11C]PK11195 binding on a voxel-by-voxel basis. Linearised versions of both plasma input and reference tissue models have been described, and these are more suitable for parametric imaging. The purpose of this study was to compare the performance of these plasma input and reference tissue parametric methods on the outcome of statistical parametric mapping (SPM) analysis of (R)-[11C]PK11195 binding. Dynamic (R)-[11C]PK11195 PET scans with arterial blood sampling were performed in 7 younger and 11 elderly healthy subjects. Parametric images of volume of distribution (Vd) and binding potential (BP) were generated using linearised versions of plasma input (Logan) and reference tissue (Reference Parametric Mapping) models. Images were compared at the group level using SPM with a two-sample t-test per voxel, both with and without proportional scaling. Parametric BP images without scaling provided the most sensitive framework for determining differences in (R)-[11C]PK11195 binding between younger and elderly subjects. Vd images could only demonstrate differences in (R)-[11C]PK11195 binding when analysed with proportional scaling due to intersubject variation in K1/k2 (blood-brain barrier transport and non-specific binding).


Subject(s)
Image Processing, Computer-Assisted/methods , Isoquinolines/metabolism , Radiopharmaceuticals/metabolism , Adult , Aged , Aging/metabolism , Brain/diagnostic imaging , Brain/metabolism , Data Interpretation, Statistical , Female , Functional Laterality/physiology , Humans , Isoquinolines/blood , Male , Middle Aged , Positron-Emission Tomography , Radiopharmaceuticals/blood , Tissue Distribution
4.
J Cereb Blood Flow Metab ; 27(9): 1603-15, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17311080

ABSTRACT

Activated microglia can be visualised using (R)-[(11)C]PK11195 (1-[2-chlorophenyl]-N-methyl-N-[1-methyl-propyl]-3-isoquinoline carboxamide) and positron emission tomography (PET). In previous studies, various methods have been used to quantify (R)-[(11)C]PK11195 binding. The purpose of this study was to determine which parametric method would be best suited for quantifying (R)-[(11)C]PK11195 binding at the voxel level. Dynamic (R)-[(11)C]PK11195 scans with arterial blood sampling were performed in 20 healthy and 9 Alzheimer's disease subjects. Parametric images of both volume of distribution (V(d)) and binding potential (BP) were obtained using Logan graphical analysis with plasma input. In addition, BP images were generated using two versions of the basis function implementation of the simplified reference tissue model, two versions of Ichise linearisations, and Logan graphical analysis with reference tissue input. Results of the parametric methods were compared with results of full compartmental analysis using nonlinear regression. Simulations were performed to assess accuracy and precision of each method. It was concluded that Logan graphical analysis with arterial input function is an accurate method for generating parametric images of V(d). Basis function methods, one of the Ichise linearisations and Logan graphical analysis with reference tissue input provided reasonably accurate and precise estimates of BP. In pathological conditions with reduced flow rates or large variations in blood volume, the basis function method is preferred because it produces less bias and is more precise.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Isoquinolines/pharmacokinetics , Microglia/diagnostic imaging , Radiopharmaceuticals/pharmacokinetics , Adult , Aged , Alzheimer Disease/diagnostic imaging , Brain/blood supply , Carbon Radioisotopes/pharmacokinetics , Evaluation Studies as Topic , Humans , Positron-Emission Tomography , Sensitivity and Specificity , Tissue Distribution
5.
Phys Med Biol ; 51(17): 4217-32, 2006 Sep 07.
Article in English | MEDLINE | ID: mdl-16912378

ABSTRACT

Positron emission tomography (PET) pharmacokinetic analysis involves fitting of measured PET data to a PET pharmacokinetic model. The fitted parameters may, however, suffer from bias or be unrealistic, especially in the case of noisy data. There are many optimization algorithms, each having different characteristics. The purpose of the present study was to evaluate (1) the performance of different optimization algorithms and (2) the effects of using incorrect weighting factors during optimization in terms of both accuracy and reproducibility of fitted PET pharmacokinetic parameters. In this study, the performance of commonly used optimization algorithms (i.e. interior-reflective Newton methods) and a simulated annealing (SA) method was evaluated. This SA algorithm, known as basin hopping, was modified for the present application. In addition, optimization was performed using various weighting factors. Algorithms and effects of using incorrect weighting factors were studied using both simulated and clinical time-activity curves (TACs). Input data, taken from [(15)O]H(2)O, [(11)C]flumazenil and [(11)C](R)-PK11195 studies, were used to simulate time-activity curves at various variance levels (0-15% COV). Clinical evaluation was based on studies with the same three tracers. SA was able to produce accurate results without the need for selecting appropriate starting values for (kinetic) parameters, in contrast to the interior-reflective Newton method. The latter gave biased results unless it was modified to allow for a range of starting values for the different parameters. For patient studies, where large variability is expected, both SA and the extended Newton method provided accurate results. Simulations and clinical assessment showed similar results for the evaluation of different weighting models in that small to intermediate mismatches between data variance and weighting factors did not significantly affect the outcome of the fits. Large errors were observed only when the mismatch between weighting model and data variance was large. It is concluded that selection of specific optimization algorithms and weighting factors can have a large effect on the accuracy and precision of PET pharmacokinetic analysis. Apart from carefully selecting appropriate algorithms and variance models, further improvement in accuracy might be obtained by using noise reducing strategies, such as wavelet filtering, provided that these methods do not introduce significant bias.


Subject(s)
Algorithms , Positron-Emission Tomography/methods , Radiometry/methods , Analysis of Variance , Body Burden , Flumazenil/chemistry , Humans , Models, Biological , Pharmacogenetics , Quality Control , Radiometry/standards , Reproducibility of Results , Sensitivity and Specificity , Water/chemistry
6.
J Cereb Blood Flow Metab ; 26(11): 1431-41, 2006 Nov.
Article in English | MEDLINE | ID: mdl-16511500

ABSTRACT

[(11)C](R)-PK11195 is a marker of activated microglia, which can be used to measure inflammation in neurologic disorders. The purpose of the present study was to define the optimal reference tissue model based on a comparison with a validated plasma input model and using clinical studies and Monte Carlo simulations. Accuracy and reproducibility of reference tissue models were evaluated using Monte Carlo simulations. The effects of noise and variation in specific binding, nonspecific binding and blood volume were evaluated. Dynamic positron emission tomography scans were performed on 13 subjects, and radioactivity in arterial blood was monitored online. In addition, blood samples were taken to generate a metabolite corrected plasma input function. Both a (validated) two-tissue reversible compartment model with K(1)/k(2) fixed to whole cortex and various reference tissue models were fitted to the data. Finally, a simplified reference tissue model (SRTM) corrected for nonspecific binding using plasma input data (SRTM(pl_corr)) was investigated. Correlations between reference tissue models (including SRTM(pl_corr)) and the plasma input model were calculated. Monte Carlo simulations indicated that low-specific binding results in decreased accuracy and reproducibility. In this respect, the SRTM and SRTM(pl_corr) performed relatively well. Varying blood volume had no effect on performance. In the clinical evaluation, SRTM(pl_corr) and SRTM had the highest correlations with the plasma input model (R(2)=0.82 and 0.78, respectively). SRTM(pl_corr) is optimal when an arterial plasma input curve is available. Simplified reference tissue model is the best alternative when no plasma input is available.


Subject(s)
Antineoplastic Agents , Isoquinolines , Microglia/metabolism , Adult , Brain Hemorrhage, Traumatic/metabolism , Humans , Image Processing, Computer-Assisted , Kinetics , Male , Middle Aged , Models, Statistical , Monte Carlo Method , Receptors, GABA-A/drug effects , Receptors, GABA-A/metabolism , Reference Standards
7.
J Cereb Blood Flow Metab ; 25(7): 842-51, 2005 Jul.
Article in English | MEDLINE | ID: mdl-15744248

ABSTRACT

(R)-[(11)C]PK11195 ([1-(2-chlorophenyl)-N-methyl-N-(1-methylpropyl]-3-isoquinoline carboxamide) is a ligand for the peripheral benzodiazepine receptor, which, in the brain, is mainly expressed on activated microglia. Using both clinical studies and Monte Carlo simulations, the aim of this study was to determine which tracer kinetic plasma input model best describes (R)-[(11)C]PK11195 kinetics. Dynamic positron emission tomography (PET) scans were performed on 13 subjects while radioactivity in arterial blood was monitored online. Discrete blood samples were taken to generate a metabolite corrected plasma input function. One-tissue, two-tissue irreversible, and two-tissue reversible compartment models, with and without fixing K(1)/k(2) ratio, k(4) or blood volume to whole cortex values, were fitted to the data. The effects of fixing parameters to incorrect values were investigated by varying them over a physiologic range and determining accuracy and reproducibility of binding potential and volume of distribution using Monte Carlo simulations. Clinical data showed that a two-tissue reversible compartment model was optimal for analyzing (R)-[(11)C]PK11195 PET brain studies. Simulations showed that fixing the K(1)/k(2) ratio of this model provided the optimal trade-off between accuracy and reproducibility. It was concluded that a two-tissue reversible compartment model with K(1)/k(2) fixed to whole cortex value is optimal for analyzing (R)-[(11)C]PK11195 PET brain studies.


Subject(s)
Brain/drug effects , Brain/metabolism , Isoquinolines/pharmacology , Models, Biological , Blood Volume , Carbon Radioisotopes , Humans , Kinetics , Monte Carlo Method , Radioactive Tracers
SELECTION OF CITATIONS
SEARCH DETAIL
...