Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 10(5)2023 Apr 27.
Article in English | MEDLINE | ID: mdl-37237610

ABSTRACT

The main aim of this study was to perform a complex biomechanical analysis for a custom-designed temporomandibular joint (TMJ) prosthesis in combination with a fibular free flap in a pediatric case. Numerical simulations in seven variants of loads were carried out on 3D models obtained based on CT images of a 15-year-old patient in whom it was necessary to reconstruct the temporal-mandibular joints with the use of a fibula autograft. The implant model was designed based on the patient's geometry. Experimental tests on a manufactured personalized implant were carried out on the MTS Insight testing machine. Two methods of fixing the implant to the bone were analyzed-using three or five bone screws. The greatest stress was located on the top of the head of the prosthesis. The stress on the prosthesis with the five-screw configuration was lower than in the prosthesis with the three-screw configuration. The peak load analysis shows that the samples with the five-screw configuration have a lower deviation (10.88, 0.97, and 32.80%) than the groups with the three-screw configuration (57.89 and 41.10%). However, in the group with the five-screw configuration, the fixation stiffness was relatively lower (a higher value of peak load by displacement of 171.78 and 86.46 N/mm) than in the group with the three-screw configuration (where the peak load by displacement was 52.93, 60.06, and 78.92 N/mm). Based on the experimental and numerical studies performed, it could be stated that the screw configuration is crucial for biomechanical analysis. The results obtained may be an indication for surgeons, especially during planning personalized reconstruction procedures.

2.
Int J Mol Sci ; 23(7)2022 Apr 03.
Article in English | MEDLINE | ID: mdl-35409345

ABSTRACT

Intervertebral cages made of Ti6Al4V alloy show excellent osteoconductivity, but also higher stiffness, compared to commonly used polyether-ether-ketone (PEEK) materials, that may lead to a stress-shielding effect and implant subsidence. In this study, a metallic intervertebral fusion cage, with improved mechanical behavior, was manufactured by the introduction of a three-dimensional (3D) mesh structure to Ti6Al4V material, using an additive manufacturing method. Then, the mechanical and biological properties of the following were compared: (1) PEEK, with a solid structure, (2) 3D-printed Ti6Al4V, with a solid structure, and (3) 3D-printed Ti6Al4V, with a mesh structure. A load-induced subsidence test demonstrated that the 3D-printed mesh Ti6Al4V cage had significantly lower tendency (by 15%) to subside compared to the PEEK implant. Biological assessment of the samples proved that all tested materials were biocompatible. However, both titanium samples (solid and mesh) were characterized by significantly higher bioactivity, osteoconductivity, and mineralization ability, compared to PEEK. Moreover, osteoblasts revealed stronger adhesion to the surface of the Ti6Al4V samples compared to PEEK material. Thus, it was clearly shown that the 3D-printed mesh Ti6Al4V cage possesses all the features for optimal spinal implant, since it carries low risk of implant subsidence and provides good osseointegration at the bone-implant interface.


Subject(s)
Alloys , Titanium , Benzophenones , Ketones/chemistry , Ketones/pharmacology , Lasers , Polyethylene Glycols/chemistry , Polyethylene Glycols/pharmacology , Prostheses and Implants , Titanium/chemistry , Titanium/pharmacology
3.
Colloids Surf B Biointerfaces ; 193: 111056, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32403035

ABSTRACT

In case of benign and malignant tumours affecting the maxillofacial region, the resection of jawbone reflects the standard therapy in more than 5.000 cases per year within the European Union. The resulting large bone defects lead to scarred, mangled facial appearance, loss of mastication and probably speech, requiring aesthetic and functional surgery as a basis for physical and physiological rehabilitation. Although autologous vascularized bone autografts reflect the current golden standard, the portion of bone available for the procedure is limited and subsequent high-dose anti-cancer chemo-/radiotherapy can lead to local tissue necrosis. Autologous vascularized bone from fibular or iliac-crest autografts is current golden standard in jawbone resection post-treatment, however, the portion of transplantable bone is limited and subsequent high-dose anti-cancer chemo-/radiotherapy often results in tissue necrosis Our research focuses on alternative treatment techniques: tissue reconstruction via novel patient-specifically manufactured maxillofacial implant that stimulates bone tissue growth. The planned neoformation of vascularized bone in such implants within the patient's own body as "bioreactor" is the safest approach in tissue engineering. The works described herein included the design of the metallic substrate of the implant with the use of computed tomography basing on real patients scans and then 3D-printing the substrates from the Ti6Al7Nb powder. The metal core was then evaluated in terms of structural characteristic, cytotoxicity and gene expression through the in vitro tests. Further experiments were focused on fabrication of the biocompatible coating for outer surface of the bone implant that would enhance the healing process and accelerate the tissue growth. Functional polymeric granulate dedicated for osteoconductive, osteoinductive and osteogenesis properties were elaborated. Another approach including the coating for the implant surface with two-phase biocompatible layer including polymeric microspheres and hydrogel carrier, which would provide long-time release of bone and cartilage growth factors around the implant were also done. The polymeric granulate containing ßTCP improved bone cells growth, but it some modification has to be done in order to improve structural pores to ensure for better osteoconductivity. The biocompatible coating including PVP hydrogel and polymeric microspheres is still in the development process.


Subject(s)
Bone Regeneration , Bone Transplantation , Coated Materials, Biocompatible/chemistry , Jaw Neoplasms/surgery , Prostheses and Implants , Animals , Cell Line , Humans , Mice , Particle Size , Surface Properties , Tissue Engineering
SELECTION OF CITATIONS
SEARCH DETAIL
...