Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Knee ; 40: 152-165, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36436384

ABSTRACT

BACKGROUND: Positioning of the implant components and tibial insert thickness constitute critical aspects of total knee replacement (TKR) that influence the postoperative knee joint dynamics. This study aimed to investigate the impact of implant component positioning (anterior-posterior and medio-lateral shift) and varying tibial insert thickness on the tibio-femoral (TF) and patello-femoral (PF) joint kinematics and contact forces after cruciate-retaining (CR)-TKR. METHOD: A validated musculoskeletal multibody simulation (MMBS) model with a fixed-bearing CR-TKR during a squat motion up to 90° knee flexion was deployed to calculate PF and TF joint dynamics for varied implant component positions and tibial insert thicknesses. Evaluation was performed consecutively by comparing the respective knee joint parameters (e.g. contact force, quadriceps muscle force, joint kinematics) to a reference implant position. RESULTS: The PF contact forces were mostly affected by the anterior-posterior as well as medio-lateral positioning of the femoral component (by 3 mm anterior up to 31 % and by 6 mm lateral up to 14 %). TF contact forces were considerably altered by tibial insert thickness (24 % in case of + 4 mm increase) and by the anterior-posterior position of the femoral component (by 3 mm posterior up to 16 %). Concerning PF kinematics, a medialised femoral component by 6 mm increased the lateral patellar tilt by more than 5°. CONCLUSIONS: Our results indicate that regarding PF kinematics and contact forces the positioning of the femoral component was more critical than the tibial component. The positioning of the femoral component in anterior-posterior direction on and PF contact force was evident. Orthopaedic surgeons should strictly monitor the anterior-posterior as well as the medio-lateral position of the femoral component and the insert thickness.


Subject(s)
Arthroplasty, Replacement, Knee , Joint Prosthesis , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Joint/physiology , Femur/surgery , Tibia/surgery , Biomechanical Phenomena , Computers , Range of Motion, Articular/physiology
2.
Materials (Basel) ; 13(10)2020 May 21.
Article in English | MEDLINE | ID: mdl-32455672

ABSTRACT

Patellofemoral (PF) disorders are considered a major clinical complication after total knee replacement (TKR). Malpositioning and design of the patellar component impacts knee joint dynamics, implant fixation and wear propagation. However, only a limited number of studies have addressed the biomechanical impact of the patellar component on PF dynamics and their results have been discussed controversially. To address these issues, we implemented a musculoskeletal multibody simulation (MMBS) study for the systematical analysis of the patellar component's thickness and positioning on PF contact forces and kinematics during dynamic squat motion with virtually implanted unconstrained cruciate-retaining (CR)-TKR. The patellar button thickness clearly increased the contact forces in the PF joint (up to 27%). Similarly, the PF contact forces were affected by superior-inferior positioning (up to 16%) and mediolateral positioning (up to 8%) of the patellar button. PF kinematics was mostly affected by the mediolateral positioning and the thickness of the patellar component. A medialization of 3 mm caused a lateral patellar shift by up to 2.7 mm and lateral patellar tilt by up to 1.6°. However, deviations in the rotational positioning of the patellar button had minor effects on PF dynamics. Aiming at an optimal intraoperative patellar component alignment, the orthopedic surgeon should pay close attention to the patellar component thickness in combination with its mediolateral and superior-inferior positioning on the retropatellar surface. Our generated MMBS model provides systematic and reproducible insight into the effects of patellar component positioning and design on PF dynamics and has the potential to serve as a preoperative analysis tool.

SELECTION OF CITATIONS
SEARCH DETAIL
...