Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Publication year range
1.
J Bone Joint Surg Am ; 105(20): 1583-1593, 2023 10 18.
Article in English | MEDLINE | ID: mdl-37624906

ABSTRACT

BACKGROUND: An increasing number of elderly patients are becoming candidates for elective total hip arthroplasty (THA). Conflicting results exist with regard to the safety of THA in nonagenarians. The aims of this study were to evaluate postoperative mortality and morbidity after THA in nonagenarians and underlying risk factors. We hypothesized that nonagenarians undergoing elective THA would show higher morbidity than younger patients and higher mortality than nonagenarians in the general population. METHODS: This was an observational cohort study using data from the German Arthroplasty Registry (Endoprothesenregister Deutschland [EPRD]). Of 323,129 THAs, 263,967 (including 1,859 performed on nonagenarians) were eligible. The mean follow-up (and standard deviation) was 1,070 ± 641 days (range, 0 to 3,060 days). The exclusion criteria were age of <60 years at admission and nonelective THAs or hemiarthroplasties. The cohort was divided into 4 age groups: (1) 60 to 69 years, (2) 70 to 79 years, (3) 80 to 89 years, and (4) ≥90 years. Comorbidities representing independent risk factors for postoperative complications and mortality were identified via a logistic regression model. Mortality rates were compared with those from the general population with data from the Federal Statistical Office. The end points of interest were postoperative major complications, minor complications, and mortality. RESULTS: Among the greatest risk factors for major and minor complications and mortality were congestive heart failure, pulmonary circulation disorders, insulin-dependent diabetes, renal failure, coagulopathy, and fluid and electrolyte disorders. Compared with younger groups, the risks of major and minor complications and mortality were significantly higher in nonagenarians. Mortality increased when major complications occurred. After 1 year, the survival rate in patients without a major complication was 94.4% compared with 79.8% in patients with a major complication. The mortality rates of nonagenarians in the study population were lower than those in the corresponding age group of the general population. The 1-year mortality rates at 90 years of age were 10.5% for men and 6.4% for women within the study group compared with 18.5% for men and 14.7% for women among the general population. CONCLUSIONS: Comorbidities favor the occurrence of complications after elective THA in nonagenarians and thus increase postoperative morbidity. In the case of complications, mortality is also increased. The fact that mortality is still lower than within the general population shows that this aspect can be controlled by careful patient selection and adequate preparation. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Hip , Male , Aged, 80 and over , Humans , Female , Aged , Middle Aged , Arthroplasty, Replacement, Hip/adverse effects , Nonagenarians , Retrospective Studies , Postoperative Complications/etiology , Risk Factors , Registries
2.
Orthopadie (Heidelb) ; 52(8): 670-676, 2023 Aug.
Article in German | MEDLINE | ID: mdl-37422578

ABSTRACT

BACKGROUND: Femoral neck fractures (FNF) are among the most common fractures in Germany and are often treated by hemiarthroplasty (HA). The aim of this study was to compare the occurrence of aseptic revisions after cemented and uncemented HA for the treatment of FNF. Secondly, the rate of pulmonary embolism was investigated. METHODS: Data collection for this study was performed using the German Arthroplasty Registry (EPRD). HAs after FNF were divided into subgroups stratified by stem fixation (cemented vs uncemented) and paired according to age, sex, BMI, and the Elixhauser score using Mahalanobis distance matching. RESULTS: Examination of 18,180 matched cases showed a significantly increased rate of aseptic revisions in uncemented HA (p < 0.0001). After 1 month 2.5% of HAs with uncemented stems required an aseptic revision, whereas 1.5% were reported in cemented HA. After 1 and 3 years' follow-up 3.9% and 4.5% of uncemented HA and 2.2% and 2.5% of cemented HA needed aseptic revision surgery. In particular, the proportion of periprosthetic fractures was increased in cementless implanted HA (p < 0.0001). During in-patient stays, pulmonary emboli occurred more frequently after cemented HA (0.81% vs 0.53% in cementless HA [OR: 1.53; p = 0.057]). CONCLUSION: For uncemented hemiarthroplasties a statistically significantly increased rate of aseptic revisions and periprosthetic fractures was evident within a time period of 5 years after implantation. During the in-hospital stay, patients with cemented HA experienced an increased rate of pulmonary embolism compared with patients with cementless HA, but this difference was not statistically significant. Based on the present results, with knowledge of prevention measures and the correct cementation technique, the use of cemented HA should be preferred in the treatment of femoral neck fractures.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Hip Prosthesis , Periprosthetic Fractures , Pulmonary Embolism , Humans , Arthroplasty, Replacement, Hip/adverse effects , Hemiarthroplasty/adverse effects , Periprosthetic Fractures/surgery , Femoral Neck Fractures/surgery , Registries , Pulmonary Embolism/epidemiology
3.
J Orthop Traumatol ; 24(1): 29, 2023 Jun 17.
Article in English | MEDLINE | ID: mdl-37329492

ABSTRACT

BACKGROUND: Indications for total hip arthroplasties (THA) differ from primary osteoarthritis (OA), which allows elective surgery through femoral neck fractures (FNF), which require timely surgical care. The aim of this investigation was to compare mortality and revisions in THA for primary OA and FNF. METHODS: Data collection for this study was performed using the German Arthroplasty Registry (EPRD) with analysis THA for the treatment of FNF and OA. Cases were matched 1:1 according to age, sex, body mass index (BMI), cementation, and the Elixhauser score using Mahalanobis distance matching. RESULTS: Overall 43,436 cases of THA for the treatment of OA and FNF were analyzed in this study. Mortality was significantly increased in FNF, with 12.6% after 1 year and 36.5% after 5 years compared with 3.0% and 18.7% in OA, respectively (p < 0.0001). The proportion for septic and aseptic revisions was significantly increased in FNF (p < 0.0001). Main causes for an aseptic failure were mechanical complications (OA: 1.1%; FNF: 2.4%; p < 0.0001) and periprosthetic fractures (OA: 0.2%; FNF: 0.4%; p = 0.021). As influencing factors for male patients with septic failure (p < 0.002), increased BMI and Elixhauser comorbidity score and diagnosis of fracture (all p < 0.0001) were identified. For aseptic revision surgeries, BMI, Elixhauser score, and FNF were influencing factors (p < 0.0001), while all cemented and hybrid cemented THA were associated with a risk reduction for aseptic failure within 90 days after surgery (p < 0.0001). CONCLUSION: In femoral neck fractures treated with THA, a significant higher mortality, as well as septic and aseptic failure rate, was demonstrated compared with prosthesis for the therapy of osteoarthritis. Increased Elixhauser comorbidity score and BMI are the main influencing factors for development of septic or aseptic failure and can represent a potential approach for prevention measures. LEVEL OF EVIDENCE: Level III, Prognostic.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hip Prosthesis , Osteoarthritis , Humans , Male , Arthroplasty, Replacement, Hip/adverse effects , Treatment Outcome , Osteoarthritis/surgery , Femoral Neck Fractures/surgery , Registries , Risk Factors , Reoperation , Prosthesis Failure
4.
Bone Joint Res ; 12(5): 331-338, 2023 May 16.
Article in English | MEDLINE | ID: mdl-37191182

ABSTRACT

Aims: The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods: Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching. Results: Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010). Conclusion: The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection.

5.
Antibiotics (Basel) ; 12(4)2023 Apr 08.
Article in English | MEDLINE | ID: mdl-37107094

ABSTRACT

BACKGROUND: Antibiotic-loaded bone cement in arthroplasties is currently experiencing increased usage. Therefore, single and double antibiotic-loaded bone cements are commercially available and used in orthopedic surgery. The aim of this investigation was to compare the clinical use of single compared to dual antibiotic-loaded bone cement for implant fixation after femoral neck fracture. Further infection rates were to be compared in (partial) arthroplasty for the treatment of femoral neck fracture for both treatment options. METHODS: On the basis of the German Arthroplasty Registry (EPRD), all cases of femoral neck fracture treated with hemiarthroplasty (HA), or total hip arthroplasty (THA) with single and dual antibiotic-loaded bone cement, were included into the data analysis. The infection risk was compared using Kaplan-Meier estimates. RESULTS: In total, 26,845 cases (HA 76.3%-THA: 23.7%) with femoral neck fracture were included. Within recent years, an increasing usage of dual antibiotic-loaded cement in Germany, with a current proportion of 7.30% in arthroplasty procedures for femoral neck fracture treatment, has been observed. In patients treated with HA, the proportion of dual antibiotic-loaded cement was 7.86%, while in those treated with THA, 5.46% of all prostheses were fixated with a two antibiotic component cement. For all arthroplasty procedures using single antibiotic-loaded bone cement after six months 1.8%, after one year 1.9%, and after five years 2.3%, of the cases failed due to periprosthetic joint infection (PJI), while in the same time period, in cases with dual antibiotic-loaded bone cement 1.5%, 1.5% and 1.5% suffered from infection (p = 0.34). A infection rate of 1.1% after HA with dual antibiotic-loaded bone cement was reported, compared to a 2.1% infection rate whilst using single antibiotic-loaded bone cement after five years (p = 0.098). The number required for treatment when using HA was 91. CONCLUSIONS: The use of dual antibiotic-loaded bone cement is increasingly used in arthroplasty procedures after femoral neck fractures. It demonstrates a reduction of PJI after HA and seems, therefore, to be a useful method for the prevention of infection, especially in patients with increased risk factors for PJI.

6.
J Orthop Traumatol ; 24(1): 9, 2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36811821

ABSTRACT

BACKGROUND: Femoral neck fractures (FNF) are among the most common fractures in Germany and are often treated by hemiarthroplasty (HA). The aim of this study was to compare the occurrence of aseptic revisions after cemented and uncemented HA for the treatment of FNF. Secondly, the rate of pulmonary embolism was investigated. METHODS: Data collection for this study was performed using the German Arthroplasty Registry (EPRD). HAs after FNF were divided into subgroups stratified by stem fixation (cemented vs uncemented) and paired according to age, sex, BMI, and the Elixhauser score using Mahalanobis distance matching. RESULTS: Examination of 18,180 matched cases showed a significantly increased rate of aseptic revisions in uncemented HA (p < 0.0001). After 1 month 2.5% of HAs with uncemented stems required an aseptic revision, while 1.5% were reported in cemented HA. After 1 and 3 years' follow-up 3.9% and 4.5% of uncemented HA and 2.2% and 2.5% of cemented HA needed aseptic revision surgery. In particular, the proportion of periprosthetic fractures was increased in cementless implanted HA (p < 0.0001). During in-patient stays, pulmonary emboli occurred more frequently after cemented HA [0.81% vs 0.53% in cementless HA (OR: 1.53; p = 0.057)]. CONCLUSION: For uncemented hemiarthroplasties a statistically significantly increased rate of aseptic revisions and periprosthetic fractures was evident within a time period of 5 years after implantation. During the in-hospital stay, patients with cemented HA experienced an increased rate of pulmonary embolism, but without statistically significant results. Based on the present results, with knowledge of prevention measurements and correct cementation technique, cemented HA should be preferred when using HA in the treatment of femoral neck fractures. TRAIL REGISTRATION: The study design of the German Arthroplasty Registry was approved by the University of Kiel (ID: D 473/11). LEVEL OF EVIDENCE: Level III, Prognostic.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Hip Prosthesis , Periprosthetic Fractures , Pulmonary Embolism , Humans , Arthroplasty, Replacement, Hip/methods , Hemiarthroplasty/methods , Periprosthetic Fractures/surgery , Femoral Neck Fractures/surgery , Reoperation , Registries , Pulmonary Embolism/surgery , Bone Cements , Treatment Outcome
7.
Orthopadie (Heidelb) ; 52(3): 222-232, 2023 Mar.
Article in German | MEDLINE | ID: mdl-36635446

ABSTRACT

BACKGROUND: Instability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD). The study investigated mechanical failure of standard and modified liner designs in primary, cementless total hip arthroplasty. Following the study, the EPRD conducted a survey of German clinics to research the utilization of lipped liners in primary total hip replacement. METHODS: The liner study included 151,096 primary, elective, cementless total hip arthroplasties. Data from November 2012 to November 2020 were obtained from the EPRD. Standard polyethylene liners were compared with lipped, angulated, offset and angulated/offset inlays. Cumulative incidences for endpoint revision due to mechanical complication were calculated with a competing risk analysis. The influence of other variables was investigated with a multivariate Cox regression. In the following online survey, 237 out of 789 hospitals completed a form. RESULTS AND CONCLUSION: In our analysis, only offset liners were, compared to standard liners, associated with a reduced risk of mechanical failure in a short to medium follow up. However, the resultant joint reaction force is increased with offset liners due to the lateralization of the hip center of rotation. Thus, the long-term performance of offset liners needs to be observed. Our survey indicated that lipped liners were implanted more often if the posterior approach was used. Moreover, lipped liners were mostly positioned with the elevated rim in the biomechanically less optimal posterior-superior quadrant. To improve stability it is suggested to position the elevated rim in the posterior-inferior quadrant.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Reoperation , Polyethylene , Registries
8.
Bone Joint J ; 104-B(7): 801-810, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35775174

ABSTRACT

AIMS: Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). METHODS: We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. RESULTS: Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). CONCLUSION: The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision. Cite this article: Bone Joint J 2022;104-B(7):801-810.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Polyethylene , Prosthesis Design , Prosthesis Failure , Registries , Reoperation
SELECTION OF CITATIONS
SEARCH DETAIL
...